X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-21302

Well Details

Well ID: 37-117-21302
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Shippen Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID:
Farm/Lease Name: DCNR 007 10V 50618
License Status: Plugged and Abandoned
Spud Date:
Permit Date: 2011-08-11
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 41.810753
Longitude: -77.412242

For data sources see[1][2][3]

Well History

Date Event
2011-08-11 New Permit Application
2011-10-01 Performed Spud Operation
2011-10-29 Drilling Completion
2012-07-20 Newly Drilled
2014-04-29 Begin Plugging
2014-08-06 Finished Plugging

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2012 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2013 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2014 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2015 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2016 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 SENECA RESOURCES CO LLC Drill Cuttings 733.41 Tons LANDFILL 301358

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2065220 Primary Facility 2012-05-03 Routine/Complete Inspection No Violations Noted A routine inspection was conducted on May 3, 2012. All E&S controls remain in place, a record of weekly inspections on behalf of Seneca was located in the mailbox with E&S plan. A copy of the ESCGP approval letter and E&S control plan were on-site.
2072703 Primary Facility 2012-05-30 Routine/Complete Inspection No Violations Noted
2163796 Primary Facility 2013-05-01 Routine/Partial Inspection Violation(s) Noted
2179591 Primary Facility 2013-07-01 Follow-up Inspection Outstanding Violations - No Viols Req'd A follow up inspection of the DCNR 007 10V well site in Tioga County, Shippen Township was conducted on July 1, 2013. Violations were cited in a 5/1/2012 inspection (2163796) for failure to maintain BMP failure to stabilize, failure to conduct weeekly inspections and failure to restore the site. The site has been temporarily stabilized with mulch, the routine inspections are being completed and documented in the mailbox. Violation of 102.4(b)(5)(x), 102.22 and 102.4(b)(1) are considered resolved. The violation of 3216 of the 2012 Oil and Gas Act (failure to restore) remains outstanding at this time. No new violations were cited during this inspection.
2296434 Primary Facility 2014-08-18 Compliance Evaluation No Violations Noted A site inspection of the DCNR 007 10V well site in Tioga County, Shippen Township was conducted on August 18, 2014. The site is stabilized with no erosion issues noted and no puddles or staining of the pad surface are evident at the time of this inspection. The erosion and sedimentation controls are deteriorated but still functioning. A roll off container, pipe and a forklift are on-site. The well has been now plugged. Violations cited in a 5/1/2012 inspection (2163796) for failure to restore are deemed corrected. To remain in compliance with Section 3216(d), this site must be restored within nine month after plugging the well. No new violations noted.
2480453 Primary Facility 2016-04-26 Routine/Complete Inspection No Violations Noted he Department of Environmental Protection (DEP) inspected the Seneca Resources – DCNR Tract 007 10V site location on 4/26/2016 @ 1230 hours. The well pad is the 3rd in sequence along an access road consisting of 3 well sites. The weather was 60° and raining. A site ID sign and mailbox was located onsite. The site was last inspected by company personnel on 3/25/2016. For “site status” the boxes for “production’ and “restoration: were checked. The boxes for “site ID”, “ E&S plan onsite and “E&S BMPs in place and working” were also checked. Site restoration appears to be underway. The road appears to have been regraded. The surface rock from the access road was removed and stockpiled on the adjacent pad G. Stumps were placed to block access to the road. The pad area appears to have been regraded to approximate original contours. A monument for the 10V well was observed surrounded by stumps. The area does not appear to have been reseeded. Equipment was delivered and staged at the entrance to the 10V access roa
2623592 Primary Facility 2017-08-07 Routine/Complete Inspection No Violations Noted
2676566 Primary Facility 2017-12-28 Plugging(Includes Plugged/Mined Through) No Violations Noted Routine Inspection of a plugged well. The well has a 2" candycane cent as a monument. No gas was detected at or around the well. I reviewed the Certificate of Well Plugging. There were no obvious issues.
2681664 Primary Facility 2018-01-11 Administrative/File Review No Violations Noted January 11, 2018: Certificate of Well Plugging for the DCNR 007 10V 50618 (117-21302) has been reviewed, signed, and sent to file.
2688015 Primary Facility 2018-01-30 Routine/Complete Inspection No Violations Noted Plugged well.

Cold/snowy at time of inspection.

Unable to identify vents due to snow cover, and vents are what appear to be 3/8's inch stainless vent line's.

No LEL/Methane detected.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2163796 667218 05/01/2013 2013-05-01 102.22 - Failure to achieve permanent stabilization of earth disturbance activity. Administrative
2163796 667219 05/01/2013 2013-05-01 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety 102.4(b)(1)
2163796 667221 05/01/2013 2013-05-01 206REST - Failure to restore site w/in 9 months of completion of drilling or plugging Environmental Health & Safety Section 3216(c) 58 Pa. C.S. §3201-3274 (relating to the Development) (“2012 Oil and Gas Act”), which states within nine months after completion of drilling of a well, the owner or operator shall restore the well site
2163796 667222 05/01/2013 2013-05-01 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety 102.4(b)(5)(x) - failure to implement a maintenance program which provides for the operation and maintenance of BMPs and inspection of BMPs on a weekly basis and after each storm event,

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
667218 297238 NOV - Notice of Violation Comply/Closed 2014-08-18
667219 297238 NOV - Notice of Violation Comply/Closed 2014-08-18
667221 297238 NOV - Notice of Violation Comply/Closed 2014-08-18
667222 297238 NOV - Notice of Violation Comply/Closed 2014-08-18

For data sources see[7]

References