X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-20624

Well Details

Well ID: 37-117-20624
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Chatham Township
Operator Name: SWEPI LP
Well Pad ID: 148148
Farm/Lease Name: CUMMINGS 823 5H
License Status:
Spud Date:
Permit Date: 2010-03-30
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.895689
Longitude: -77.379650

For data sources see[1][2][3]

Well History

Date Event
2010-03-30 New Permit Application
2010-04-14 Performed Spud Operation
2010-07-17 Drilling Completion
2012-08-16 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-01-21 2011-01-21 4,742 3,593,368

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Superflo 100 CESI Chemical Aids in Wetability and Flowback Citrus terpenes 94266-47-4 0.01
Isopropanol 67-63-0 0.01
Scale Inhibitor Clearwater International Prevents Scale Ethylene glycol 107-21-1 0.00799000
Sand Various Proppagates Frac Quartz 14808-60-7 16.80
Acid Inhibitor Clearwater International Protects Steel Propargyl alcohol 107-19-7 0.00033000
Ethoxylated Nonylphenol 0.00011000
2-Butoxyethanol 111-76-2 0.00033000
Isopropanol 67-63-0 0.00033000
Friction Reducer Clearwater International Reduce psi and HHP Polyacrylamide 9003-05-8 0.02
Water Shell Carrier Fluid Hydrochloric acid 7647-01-0 100.00
Produced Water Shell Carrier Fluid H2O + Disolved Salts 100.00
Acid Various Opens Perfs Hydrochloric acid 7647-01-0 0.05
Biocide Nalco Kills Bacteria Dibromoacetonitrile 3252-43-5 0.00054000
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 0.00326000
Polyethylene glycol 25322-68-3 0.00653000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EAST RESOURCES MGMT LLC 0.00 0 0.00 0 0.00 0
2011 SWEPI LP 144,282.68 265 0.00 0 0.00 0
2012 SWEPI LP 115,664.27 366 0.00 0 0.00 0
2013 SWEPI LP 83,253.64 311 0.00 0 0.00 0
2014 SWEPI LP 58,516.16 242 0.00 0 0.00 0
2015 SWEPI LP 65,745.25 273 0.00 0 0.00 0
2016 SWEPI LP 64,255.96 345 0.00 0 0.00 0
2017 SWEPI LP 63,288.79 365 0.00 0 0.00 0
2018 SWEPI LP 40,991.30 141 0.00 0 0.00 0
2019 SWEPI LP 40,471.04 119 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 SWEPI LP Fracing Fluid Waste 18,021.50 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SWEPI LP Produced Fluid 241.43 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 SWEPI LP Fracing Fluid Waste 456.67 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 SWEPI LP Produced Fluid 4,403.43 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012 SWEPI LP Fracing Fluid Waste 2,323.57 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SWEPI LP Fracing Fluid Waste 18.65 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012 SWEPI LP Produced Fluid 1,440.55 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SWEPI LP Produced Fluid 303.33 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2012 SWEPI LP Fracing Fluid Waste 16.67 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2013 SWEPI LP Produced Fluid 426.89 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 SWEPI LP Fracing Fluid Waste 569.85 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SWEPI LP Produced Fluid 87.01 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 SWEPI LP Produced Fluid 6,089.85 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SWEPI LP Drilling Fluid Waste 965.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Fracing Fluid Waste 555.25 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Fracing Fluid Waste 9.17 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 SWEPI LP Produced Fluid 1,233.20 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Drilling Fluid Waste 199.44 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWEPI LP Produced Fluid 83.35 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC011
2015 SWEPI LP Fracing Fluid Waste 214.54 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWEPI LP Produced Fluid 51.15 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SWEPI LP Produced Fluid 850.17 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 SWEPI LP Produced Fluid 897.07 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWEPI LP Produced Fluid 75.80 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 SWEPI LP Produced Fluid 2,798.44 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWEPI LP Produced Fluid 100.02 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2017 SWEPI LP Produced Fluid 561.80 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017 SWEPI LP Produced Fluid 33.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 SWEPI LP Produced Fluid 1,136.97 Bbl REUSE (AT WELL PAD)
2017 SWEPI LP Produced Fluid 34.60 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 SWEPI LP Produced Fluid 162.36 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 SWEPI LP Produced Fluid 83.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018 SWEPI LP Produced Fluid 53.56 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 SWEPI LP Produced Fluid 680.84 Bbl REUSE (AT WELL PAD)
2019 SWEPI LP Produced Fluid 28.39 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 SWEPI LP Produced Fluid 83.34 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2019 SWEPI LP Produced Fluid 359.67 Bbl REUSE (AT WELL PAD)
2019 SWEPI LP Produced Fluid 35.73 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 SWEPI LP Produced Fluid 183.32 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2009248 Primary Facility 2011-10-07 Routine/Complete Inspection No Violations Noted 102.4(b)(1) viol cited under 1H (#2009096). TLT
2032201 Primary Facility 2012-01-06 Follow-up Inspection No Violations Noted
2060788 Primary Facility 2012-04-11 Routine/Complete Inspection No Violations Noted
2109911 Primary Facility 2012-10-15 Follow-up Inspection No Violations Noted
2252415 Primary Facility 2014-02-11 Follow-up Inspection No Violations Noted
2340189 Primary Facility 2015-02-02 Administrative/File Review No Violations Noted This inspection is in response to receiving a Well Site Restoration Report submitted to the Department. A review of the Off-Site Waste Disposal information documented in the report was conducted and no deficiencies were identified. Due to snow cover, compliance with 25 PA Code § 102.22 (a)(2)(i) Permanent stabilization could not be verified at this time. 25 PA Code § 102.22 (a)(2)(i) states for an earth disturbance activity or any stage or phase of an activity to be considered permanently stabilized, the disturbed areas shall be covered with a minimum uniform 70% perennial vegetative cover, with a density capable of resisting accelerated erosion and sedimentation. A follow-up inspection will be conducted to determine if this site meets the stabilization requirements when field conditions allow.
2386049 Primary Facility 2015-07-06 Site Restoration No Violations Noted The Department inspected the SWEPI LP – Cummings 823 site on 7/6/15 @1300 hours in response to receipt of a Notice of Termination received by the Department on 7/1/2015. The weather was 75° and mostly cloudy. No temporary E&S controls were observed. All slopes appeared to contain at least 70% vegetative cover. This inspection meets the requirements of 25 PA Code §102.22(a)(1)(2). No violations were cited during this inspection. This NOT is recommended for approval at this time.
2654743 Primary Facility 2017-10-31 Routine/Partial Inspection No Violations Noted I got electrical conductivity readings from all the secondary containments and 2 puddles on the pad with an Oakton PCSTestr 35; all were <0.35 mS/cm.
2775708 Primary Facility 2018-09-17 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of the SWEPI LP - Cummings Unit 823 Well pad located in Chatham Twp, Tioga Co. on 9/17/2018 @1200 hours. The weather was 72 degrees, cloudy, winds N 11mph. Present for the inspection was myself and Korey Starkey, DEP Env Trainee.

The access road, well pad and E&S controls were observed. An adequate site ID sign was observed at the entrance to access road. The well pad appears to be in production, however, all pressure gauges attached to production equipment registered 0 PSI, so the wells do not appear to be producing at this time. One rolloff tank was observed on secondary containment located on the southern corner of the pad. All puddles on the pad surface were screened for field conductivity and found to be <1000 uS/cm.

The area surrounding the pad appeared stabilized by >70% vegetative cover. No erosion or sedimentation was observed. No violations are noted at this time.

We departed the site at 1245 hours.

2810062 Primary Facility 2018-12-04 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of SWEPI's Cummings 823 Well Pad in Chatham Twp, Tioga County on 12/4/2018 at 1200 hours. The weather was partly cloudy and 28 degrees.

There are currently 6 wells onsite with 6 production tanks. All fluids on pad surface were within normal conductivity ranges. There were some higher conductivity readings but were in secondary containment. Pad appears to be stabilized and vegetated.

No violations noted at this time. I departed the site at 1220.

For data sources see[8]

References