37-117-20481

Well Details

Well ID: 37-117-20481
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Elk Township
Operator Name: TILDEN MARCELLUS LLC
Well Pad ID: 149452
Farm/Lease Name: TRACT 839 815 1H
License Status: INACTIVE
Spud Date:
Permit Date: 2009-11-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.688066
Longitude: -77.528159

For data sources see[1][2][3]

Well History

Date Event
2009-11-10 New Permit Application
2010-05-03 Performed Spud Operation
2010-06-08 Drilling Completion
2010-09-15 Perforation
2011-04-29 DEVIATED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 ULTRA RESOURCES INC 0.00 0 0.00 0 0.00 0
2010 ULTRA RESOURCES INC 16,158.21 37 0.00 0 0.00 0
2011 ULTRA RESOURCES INC 85,295.00 321 0.00 0 0.00 0
2012 ULTRA RESOURCES INC 53,703.00 312 0.00 0 0.00 0
2013 ULTRA RESOURCES INC 39,591.00 265 0.00 0 0.00 0
2014 SWEPI LP 642.00 26 0.00 0 0.00 0
2015 SWEPI LP 327.95 5 0.00 0 0.00 0
2016 SWEPI LP 0.00 0 0.00 0 0.00 0
2017 SWEPI LP 0.00 0 0.00 0 0.00 0
2019 SWEPI LP 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 ULTRA RESOURCES INC Produced Fluid 9.18 Bbl REUSE OTHER THAN ROAD SPREADING
2013 ULTRA RESOURCES INC Produced Fluid 24.60 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2013 ULTRA RESOURCES INC Produced Fluid 13.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 ULTRA RESOURCES INC Produced Fluid 18.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2017 SWEPI LP Other Oil & Gas Wastes 19.81 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2019 TILDEN MARCELLUS LLC Other Oil & Gas Wastes 100.00 Bbl REUSE (AT WELL PAD)
2019 TILDEN MARCELLUS LLC Produced Fluid 175.00 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2014675 Primary Facility 2011-10-28 Routine/Complete Inspection Violation(s) Noted
2053488 Primary Facility 2012-03-20 Routine/Complete Inspection No Violations Noted A routine inspection was conducted at the State Tract 839; 815 pad on Mar. 20, 2012. The perimeter of the site was walked and several puddles were screened for the presence of elevated specific conductance, no elevated readings were found. The site ID sign and well tags were present. The cut and fill slopes of the pad are in need of further stabilization. Four wells are permitted on this site and all four are drilled. Site restoration is required within 9 months of drilling the last permitted well. No violations were cited during this inspection. MRN
2385755 Primary Facility 2015-07-06 Routine/Complete Inspection No Violations Noted
2479514 Primary Facility 2016-04-21 Routine/Partial Inspection No Violations Noted The Department of Environmental Protection (DEP) conducted a routine partial inspection of the SWEPI LP – DCNR Tract 839 815 Well site (ESG09-117-0053) on 4/21/2016 @1330 hours, located in Gaines/Elk Twp., Tioga Co., during an onsite meeting to discuss restoration of the site. Present for the meeting were Dan DiCamillo, DCNR Forester & Gas Lease Administrator; Jason VanDergrift, SWEPI – Civil Construction Supervisor; Troy Spehar, SWEPI and Jeff Watts, J.L. Watts.

The pad surface appears mostly vegetated. The submitted restoration drawings show removal of the E&S sediment traps on either side of the pad surface. Infiltration berms will then be installed to meet the PCSM BMP requirements. There are 3 active wells on the pad, the 2H, 3H, and 4H. There does not appear to be any plans to reduce the pad size. Construction of the PCSM BMPs is scheduled to begin next week. No violations are issued at this time. I departed the site @1330 hours.

This inspection report references the following well permits –

API#

2484298 Primary Facility 2016-05-04 Routine/Complete Inspection No Violations Noted
2602848 Primary Facility 2017-06-05 Routine/Complete Inspection No Violations Noted On 6/5/17 at 0930 hrs I conducted a routine inspection at the State 815 well site. It was overcast and 66 degrees F. No one was present during my inspection.

The 1H - 4H wells have been drilled. Production equipment is present at the site, however, was not running at the time of my inspection. According to DEP records, the 1H was placed on inactive status on 12/23/15 and the 2H - 4H wells remain on active status. The wells were tagged.

Containment structures at the site were observed. The production tank containment held water; the specific conductance field measurement of the containment water was 278 micro Siemens/cm (Photo #1).

A temporary containment structure holding four totes was located on the south side of the dehydration unit (Photo #2). The two totes on the west side of the containment appeared to be empty. Non-hazardous Waste labels were affixed to the other two totes. One tote held a reddish/pink fluid; the label was dated 4/11/17 and -not sure- was listed for the contents (Photo #4). The top

2612941 Primary Facility 2017-07-06 Compliance Evaluation No Violations Noted On 7/6/17 at 1343 hrs I conducted a follow up inspection at the State 815 well site. No one was present during my inspection. It was overcast and 73 degrees F.

The purpose of the inspection was to verify that a violation cited against the 4H permit (117-20484) during the 6/5/17 inspection had been resolved. During the 6/5/17 inspection, I observed a compromised containment structure holding four totes; one of the totes was broken, exposing the waste inside. A Notice of Violation (NOV) was sent to SWEPI on 6/9/17; SWEPI's written response was received on 6/23/17.

Since the last inspection, the containment structure and totes have been removed. No staining was observed in the gravel area where the totes had been staged. The violation is hereby corrected. SWEPI is documenting their containment Inspections; the most recent one was completed on 7/2/17.

I concluded the inspection at 1520 hrs. TLT

2626935 Primary Facility 2017-08-10 Routine/Complete Inspection No Violations Noted

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2014675 623393 10/28/2011 2011-10-28 201H - Failure to properly install the permit number, issued by the department, on a completed well. Administrative

For data sources see[7]