37-115-21992

Well Details

Well ID: 37-115-21992
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Harford Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 152445
Farm/Lease Name: DECKER T 7
License Status: Active
Spud Date: 2015-05-13
Permit Date: 2015-04-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.783964
Longitude: -75.693836

For data sources see[1][2][3]

Well History

Date Event
2015-04-10 New Permit Application
2015-05-12 Performed Spud Operation
2015-07-06 Drilling Completion
2016-05-05 Perforation
2016-07-11 Perforation
2016-07-11 Performed Stage 1 of Stimulation
2016-07-12 Perforation
2016-07-12 Performed Stage 2 of Stimulation
2016-07-13 Performed Stage 3 of Stimulation
2016-07-14 Perforation
2016-07-14 Performed Stage 4 of Stimulation
2016-07-15 Perforation
2016-07-15 Performed Stage 5 of Stimulation
2016-07-16 Perforation
2016-07-16 Performed Stage 6 of Stimulation
2016-07-17 Perforation
2016-07-17 Performed Stage 7 of Stimulation
2016-07-18 Perforation
2016-07-18 Performed Stage 8 of Stimulation
2016-07-19 Perforation
2016-07-19 Performed Stage 9 of Stimulation
2016-07-20 Perforation
2016-07-20 Performed Stage 10 of Stimulation
2016-07-21 Perforation
2016-07-21 Performed Stage 11 of Stimulation
2016-07-22 Perforation
2016-07-22 Performed Stage 12 of Stimulation
2016-07-23 Perforation
2016-07-24 Perforation
2016-07-24 Performed Stage 13 of Stimulation
2016-07-25 Perforation
2016-07-25 Performed Stage 14 of Stimulation
2016-07-25 Performed Stage 15 of Stimulation
2017-01-20 Deviated

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2016-07-10 2016-07-24 6,941 5,400,610 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Chemplex 4-N-1 Chemplex Combination/Iron Control Acetic Acid 64-19-7 85 0.00158462 810.333
Diethanolamine 111-42-2 2 0.00003729 19.067
Propargyl Alcohol 107-19-7 1 0.00001864 9.533
Cocamide Diethanolamine Salt 68603-42-9 2 0.00003729 19.067
2-Ethylhexanol 104-76-7 10 0.000186426 95.333
n-olefins Proprietary 1 0.00001864 9.533
Alcohol Ethoxylate Surfactants Proprietary 2 0.00003729 19.067
thiourea-formaldehyde copolymer 68527-49-1 2 0.00003729 19.067
Methyl Alcohol 67-56-1 10 0.000186426 95.333
Water Operator Carrier/Base Fluid Water 7732-18-5 100 88.4253 45,218,200.0
Greenhib 679 Chemplex Friction Reducer Proprietary Proprietary 35 0.00824571 4216.63
Glycerine 56-81-5 20 0.00471184 2409.5
Plexcide 15G Chemplex Biocide Glutaraldehyde 111-30-8 14 0.00309214 1581.24
Ethanol 64-17-5 3 0.000662602 338.836
Alkyl Dimethyl Benzyl Ammonium Chloride 68424-85-1 3 0.000662602 338.836
Didecyl Dimethyl Ammonium Chloride 7173-51-5 3 0.000662602 338.836
Plexslick 957 Chemplex Friction Reducer Ammonium Chloride 12125-02-9 5 0.00431378 2205.95
Nonionic Surfactants Proprietary 1.5 0.00129413 661.784
Paraffinic, Naphtehenic Solvent 64742-47-8 30 0.0258827 13235.7
Poly (acrylamide-co-acrylic acid), partial sodium salt 62649-23-4 35 0.0301964 15441.6
Sand TSS Proppant Silica Substrate 14808-60-7 100 11.1616 5,707,710.0
15% HCL Reagent Acidizing Hydrochloric Acid 7647-01-0 15 0.0419068 21430

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2016-07-11 1 SAND, WHITE 493,545 7,005 8,450
2016-07-12 2 SAND, WHITE 493,545 7,009 7,950
2016-07-13 3 SAND, WHITE 493,545 7,154 7,490
2016-07-14 4 SAND, WHITE 493,545 6,679 7,700
2016-07-15 5 SAND, WHITE 493,545 6,837 8,000
2016-07-16 6 SAND, WHITE 493,545 6,844 7,830
2016-07-17 7 SAND, WHITE 493,545 6,742 7,650
2016-07-18 8 SAND, WHITE 493,545 6,699 8,450
2016-07-19 9 SAND, WHITE 493,545 6,657 8,380
2016-07-20 10 SAND, WHITE 493,545 6,724 8,220
2016-07-21 11 SAND, WHITE 493,545 6,466 8,350
2016-07-22 12 SAND, WHITE 493,545 6,490 7,400
2016-07-24 13 SAND, WHITE 493,545 6,269 7,490
2016-07-25 14 SAND, WHITE 493,545 5,799 8,040
2016-07-25 15 SAND, WHITE 493,545 5,327 7,120

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2015 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 755,775.79 151 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 1,213,314.61 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 762,151.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 550,396.00 315 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2015 CABOT OIL & GAS CORP Drilling Fluid Waste 565.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 CABOT OIL & GAS CORP Drill Cuttings 1,020.52 Tons LANDFILL 101247
2015 CABOT OIL & GAS CORP Drilling Fluid Waste 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2016 CABOT OIL & GAS CORP Fracturing Fluid Waste 4,059.46 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 2,508.75 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE004
2016 CABOT OIL & GAS CORP Synthetic Liner Materials 10.55 Tons LANDFILL 101247
2016 CABOT OIL & GAS CORP Fracturing Fluid Waste 5,343.31 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE004
2016 CABOT OIL & GAS CORP Produced Fluid 175.05 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Waste Water Treatment Sludge 11.49 Tons LANDFILL 100933
2016 CABOT OIL & GAS CORP Other Oil & Gas Wastes 0.06 Tons RESIDUAL WASTE PROCESSING FACILITY 301333
2017 CABOT OIL & GAS CORP Produced Fluid 263.44 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 1,147.53 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017 CABOT OIL & GAS CORP Produced Fluid 439.39 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 CABOT OIL & GAS CORP Produced Fluid 359.72 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 46.57 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2018 CABOT OIL & GAS CORP Produced Fluid 202.03 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 162.31 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 584.48 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2019 CABOT OIL & GAS CORP Synthetic Liner Materials 2.51 Tons RESIDUAL WASTE TRANSFER FACILITY 101714

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2379514 Primary Facility 2015-05-12 Preoperation Inspection No Violations Noted On 5/12/15, the Department conducted a Preoperational inspection of the Cabot Decker T. Pad located in Harford Township, Susquehanna County. The well pad is approximately 95% complete with all E&S BMP’s installed per plan. Major earth moving has not been started for the tank pad. All filter sock controls have been installed for the tank pad. No violations noted. The well permits that have been issued for the pad are: Decker T. 1H(115-21988), 2H(115-21989), 3H(115-21990), 5H(115-21991), and the 7H(115-21992).
2383714 Primary Facility 2015-06-29 Drilling/Alteration No Violations Noted
2384474 Primary Facility 2015-06-29 Drilling/Alteration No Violations Noted
2385060 Primary Facility 2015-07-02 Complaint Inspection No Violations Noted
2470994 Primary Facility 2016-04-01 Routine/Complete Inspection No Violations Noted
2480876 Primary Facility 2016-05-04 Drilling/Alteration No Violations Noted
2485716 Primary Facility 2016-05-18 Routine/Complete Inspection No Violations Noted
2497872 Primary Facility 2016-07-01 Drilling/Alteration No Violations Noted
2500600 Primary Facility 2016-07-12 Drilling/Alteration No Violations Noted
2500731 Primary Facility 2016-07-12 Routine/Complete Inspection No Violations Noted On 7/12/16, the Department conducted an inspection of the Cabot Decker T Well Pad located in Harford Township, Susquehanna County. The inspection involved reviewing the fill section of the pad that Williams is actively installing pipeline. This section of the pad looked good. Recent heavy rain events showed no impacts below the pads E&S and storm water controls. Fracking operations were observed taking place. Sand trucks were observed actively entering and leaving the pad. Water is being delivered to the pad via an above ground water line which is coming off the tank pad which has a battery of tanks on-site, located about an 1/8 of a mile away. No issues were observed from the installation and use of this line. Joe Gaboff, Department OGI was on the pad and noted that fracking of the 3H was being conducted at the time of his inspection. The other wells on this pad that are presumably being stimulated are the 1H, 2H, 5H, and 7H. No violations noted.
2507118 Primary Facility 2016-08-02 Routine/Complete Inspection No Violations Noted On 8/2/2016, the Department conducted an inspection of the COG Decker T Pad located in Harford Township, Susquehanna County. A crew from Stallion Oilfield Services is on-site conducting flow back operations. As of the inspection, the 1H and the 2H have been flowed back and are ready for production. The 3H, 5H, and the 7H are also slated to be prepped for production. Recent rain events have left some standing water on all four quadrants of the pad. Conductivity testing of the standing water in all four quadrants found no indicators that a release has occurred. During the inspection crews were actively vacuuming up excess water from almost all containment on the pad. Pad stability looks good. Pipeline tie-in to the pad looks stable. A review of the tank pad revealed all tanks and containment have been removed. Conductivity readings were also relatively low on this pad. No violations noted. The poly line has been removed that connected the tank pad to the well pad.
2510506 Primary Facility 2016-08-11 Routine/Partial Inspection No Violations Noted
2516404 Primary Facility 2016-08-29 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 9:50a.m., I talked to well tender Jeremy Rapp and he told me the wells were turned into production on 8/22/16. They were still producing through sand separators and the fluid was going into a 500bbl flow back tank at about 34bbls per hour, the fluid was being hauled to Comtech. The cellar had water at the bottom with no bubbling noticed, the (13x9) vent pipe was open and venting into a tank, the (9x5) vent pipe was open and venting into a tank, there was 536psi on the production casing. I took a walk around the location and everything looked OK.

I left the site at 10:45a.m.

2516775 Primary Facility 2016-08-30 Routine/Complete Inspection No Violations Noted On 8/30/16, the Department conducted an inspection of the COG Decker T Pad located in Harford Township, Susquehanna County. Good stabilization of the site exists. E&S BMP’s still emplaced and in good condition. Perennial vegetation appears to be well established. All 5 wells associated with this well pad have been drilled, stimulated, and appear to be in production. Most drill rig/stimulation containment has been removed. Permanent production equipment has been installed and is operational. A frac tank is located next to the permanent production fluid containment, and appears to be present to increase holding volume of initial produced fluid. 2 large roll off containers on-site, on containment with sawdust in each presumably being utilized for bulking purposes. Large number of frac tanks(20ish) still on pad on containment. A small crew was on-site removing temporary buried piping. No visible sign of a release was observed. No violations noted.
2533806 Primary Facility 2016-11-01 Routine/Complete Inspection No Violations Noted On 11/1/16, the Department conducted an inspection of the COG Decker T Well Site located in Harford Township, Susquehanna County in response to a nearby malodor complaint. The Department arrived on-site at approximately 11:00 AM. There are 5 wells drilled and in production on this pad, the 1H, 2H, 3H, 5H and the 7H. The pad is equipped with the standard equipment associated with steady state production. There was also a backhoe and a utility truck parked on the pad. No other activity is occurring at this pad. I spent approximately 5 minutes at each corner of the well pad and did not detect any malodors. No E&S issues were observed during this inspection. No violations noted.
2612744 Primary Facility 2017-07-06 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:45p.m.

The cellar was about a quarter full of water with no bubbling noticed. The (20x13) annulus vent pipe was open and venting into a small plastic tank, the (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. All the annulus vent pipes were connected to one pipe going into the same tank. There was 520psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:25p.m.

2683532 Primary Facility 2018-01-17 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Site covered by about 7" of fresh snow. Well pad and access road have been plowed. No obvious E&S issues noted during the inspection. All wells drilled on pad appear to be in production. No violations noted.
2716931 Primary Facility 2018-04-10 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The (20x13), (13x9) and (9x5) annuli vent pipes were connected together and going to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2774371 Primary Facility 2018-09-12 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Standing water on the pad surface was tested for conductivity with all results confirmed to be less than 215 uS. Good, permanent stability of the site exists. No violations noted.
2819664 Primary Facility 2018-12-27 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 7' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar with a MSA Altair 5X multi gas detector that was calibrated on 12/3/18. The (20x13), (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 12/3/18. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2826149 Primary Facility 2019-01-11 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. All five wells appear to be in production. Overall the site has good Stabilization. No E&S issues identified. No violations noted.
2856650 Primary Facility 2019-03-20 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Overall the site appears to have good stabilization. No E&S issues identified. No violations noted.

For data sources see[9]