Well Details

Well ID: 37-115-21814
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Bridgewater Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 151400
Farm/Lease Name: FONTANA C 2
License Status:
Spud Date:
Permit Date: 2014-06-09
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.829656
Longitude: -75.823864

For data sources see[1][2][3]

Well History

Date Event
2014-06-09 New Permit Application
2014-09-18 Performed Spud Operation
2014-12-01 Drilling Completion
2015-01-17 Perforation
2015-02-21 Performed Stimulation
2015-06-09 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2015-02-21 2015-03-02 6,505 8,860,610 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Greenhib 679 Chemplex Friction Reducer Glycerine 56-81-5 20 0.00475577 3998.39
Proprietary Proprietary 35 0.0083226 6997.18
Sand (Proppant) TSS Proppant Silica Substrate 14808-60-7 100 11.3084 9,507,500.0
Plexslick 957 Chemplex Friction Reducer Paraffinic, Naphtehenic Solvent 64742-47-8 30 0.0233259 19611.1
Nonionic Surfactants Proprietary 1.5 0.00116629 980.555
Poly (acrylamide-co-acrylic acid), partial sodium salt 62649-23-4 35 0.0272135 22879.6
Ammonium Chloride 12125-02-9 5 0.00388764 3268.51
Hydrochloric Acid (15%) Reagent Acidizing Hydrochloric Acid 7647-01-0 15 0.0459667 38646.3
Chemplex 4-N-1 Chemplex Combination/Iron Control n-olefins Proprietary 1 0.00001858 15.623
Propargyl Alcohol 107-19-7 1 0.00001858 15.623
2-Ethylhexanol 104-76-7 10 0.000185819 156.226
Alcohol Ethoxylate Surfactants Proprietary 2 0.00003716 31.245
Diethanolamine 111-42-2 2 0.00003716 31.245
Methyl Alcohol 67-56-1 10 0.000185819 156.226
thiourea-formaldehyde copolymer 68527-49-1 2 0.00003716 31.245
Cocamide Diethanolamine Salt 68603-42-9 2 0.00003716 31.245
Acetic Acid 64-19-7 85 0.00157946 1327.92
Plexcide 15G Chemplex Biocide Ethanol 64-17-5 3 0.000644393 541.77
Glutaraldehyde 111-30-8 14 0.00300717 2528.26
Didecyl Dimethyl Ammonium Chloride 7173-51-5 3 0.000644393 541.77
Alkyl Dimethyl Benzyl Ammonium Chloride 68424-85-1 3 0.000644393 541.77
Water Rockwater Carrier/Base Fluid Water 7732-18-5 100 88.2603 74,204,300.0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2015-02-21 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 4,110,574.94 279 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 3,320,773.88 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 1,795,972.84 355 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 1,421,017.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 1,025,102.00 364 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 CABOT OIL & GAS CORP Drill Cuttings 1,138.09 Tons LANDFILL 101247
2015 CABOT OIL & GAS CORP Fracing Fluid Waste 132.74 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2015 CABOT OIL & GAS CORP Fracing Fluid Waste 11,954.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 5,019.10 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 47.69 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 425.49 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 631.38 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Synthetic Liner Materials 2.38 Tons LANDFILL 101247
2017 CABOT OIL & GAS CORP Produced Fluid 237.28 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 352.59 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Servicing Fluid 120.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Soil Contaminated by Oil & Gas Related Spills 5.43 Tons LANDFILL 100933
2018 CABOT OIL & GAS CORP Produced Fluid 226.84 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Soil Contaminated by Oil 5.43 Tons LANDFILL 100933
2018 CABOT OIL & GAS CORP Produced Fluid 143.54 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 282.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2294049 Primary Facility 2014-08-01 Incident- Response to Accident or Event No Violations Noted
2300945 Primary Facility 2014-09-04 Administrative/File Review No Violations Noted Violations immediately corrected are associated with the site. The ESCGP number is ESX29-115-14-0004. E-facts identification number is 2300929.
2300960 Primary Facility 2014-09-03 Administrative/File Review No Violations Noted Violations immediately corrected are associated with the site. The ESCGP number is ESX29-115-14-0004. E-facts identification number is 2300958.
2303058 Primary Facility 2014-08-25 Routine/Partial Inspection No Violations Noted
2304014 Primary Facility 2014-09-09 Routine/Partial Inspection No Violations Noted
2347536 Primary Facility 2015-02-24 Routine/Complete Inspection No Violations Noted The Department was on site to perform a routine complete inspection at the Fontana Well Pad
2367117 Primary Facility 2015-05-05 Routine/Complete Inspection No Violations Noted
2381022 Primary Facility 2015-06-22 Routine/Partial Inspection No Violations Noted
2437391 Primary Facility 2016-01-04 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:40 p.m., the cellar was full of water with no bubbling noticed, the (13x9) vent pipe was open and venting to a tank, the (9x5) vent pipe was open and venting to a tank, there was 628psi on the production casing. I took a walk around the location and everything looked OK.

I left the site at 14:10 p.m.

2498879 Primary Facility 2016-06-27 Complaint Inspection No Violations Noted 1900- Spoke to Complainant about the noise and grey/white smoke coming from the C. Fontana well pad. Complainant indicated that a loud hissing noise with grey/white billowing smoke was coming from the C. Fontana well pad. Complainant stated that she called the Cabot emergency number. Cabot informed Complainant that personnel are in the process of relieving pressure from the production equipment. Complainant voiced concerns about the duration (approximately 20 minutes) and the presence of the smoke.

Arrived at the C. Fontana well pad, the gate at the access road was locked. There weren't any Cabot personnel on-site. On the well pad, no noise or smoke was detected. Inspected the C. Fontana 2H, 4H and 6H gas wells. The wells were in production. No leaks were detected at the well heads and no bubbling was observed in the water filled well cellars. The gas production units (GPUs) for the C. Fontana wells were inspected. No leaks were detected. No evidence of spills were observed around the well heads or GPUs. Ins

2498882 Primary Facility 2016-06-28 Complaint Inspection No Violations Noted On 6/28/2016, David Schoonover (DEP-Oil and Gas Inspector) contacted Michael Hall (Cabot- Production Foreman). Mr. Hall indicated that, at the time of the complaint, Scott Allen (Cabot Well Tender) was at the C. Fontana pad blowing down the C. Fontana 4H in an effort to remove fluid from the well. No issues were reported during this process.
2508883 Primary Facility 2016-06-13 Routine/Complete Inspection No Violations Noted Inspection of the Fontana C P1 well pad in conjunction with the Fontana Well Connect Pipeline notice of termination inspection. There were no issues observed on the well pad at the time of the inspection.
2538860 Primary Facility 2016-11-22 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 9:55a.m., the cellar had water at the bottom with no bubbling noticed. The (13x9) vent pipe was open and venting into a small poly tank, the (9x5) vent pipe was open and venting into a small poly tank. There was 510psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 10:30a.m.

2559585 Primary Facility 2017-02-08 Routine/Complete Inspection No Violations Noted The Department was on site at the Fontana well site located at 2639 Post Pond Road Bridgewater Township to conduct a Routine Complete Inspection. I reviewed the E&S Inspection Log which stated that Sam Wiernusz conducted the most recent inspection on 2/2/17 and it was a Post Precipitation Inspection. The site appeared to meet temporary stabilization requirements. Several areas on the site appeared to have been recently seeded and mulched/covered in erosion control blanket.
2600432 Primary Facility 2017-05-30 Incident- Response to Accident or Event Viol(s) Noted & Immediately Corrected The Department received a report from Cabot Oil and Gas concerning a release that occurred on 5/25/17 at 1700 hours. Mr. Watson contacted the DEP after hours hotline at 1753 and received a return call from Bob Bisignani (DEP). It was reported as less than 1bbl, but the exact volume was not determined. A well was being flowed black into a flow back tank in an attempt to increase gas production on the 2H well. A well tubing hanger was temporarily removed, to increase the diameter of the well, and the well was flowed to a flowback tank. When the well was turned back in line fluid in the gas supply line (not typical) was forced to the GPU.

I met with Mr. Watson on site to conduct the inspection. The inspection was conducted during a heavy rainstorm. .

2626922 Primary Facility 2017-08-16 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:00p.m.

The cellar had water at the bottom with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. All the annulus vent pipes were connected to one pipe going into the same tank. There was 487psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:40p.m.

2676727 Primary Facility 2017-12-27 Site Restoration No Violations Noted I performed a Notice of Termination (NOT) inspection on the Fontana well site on December 27, 2017. The site was solid and stable and the slopes were all well covered with last years vegetation, at or in excess of the 70% perennial growth standard required.

The well pad has been reduced in size from approximately 765'x330' to 343'x265'.

The vegetated filter strip PCSM is in place and well vegetated with last years growth.

All wells were properly labeled and had a legible tag The wells associated with this site are as follows: 115-21814 115-21815 115-21816


There were no violations observed.

I recommend APPROVAL of this NOT.

2679074 Primary Facility 2018-01-08 Routine/Complete Inspection No Violations Noted I performed a Notice of Termination (NOT) inspection on the Fontana well site on December 27, 2017. The site was solid and stable and the slopes were all well covered with last years vegetation, at or in excess of the 70% perennial growth standard required.

The well pad has been reduced in size from approximately 765'x330' to 343'x265'.

The vegetated filter strip PCSM is in place and well vegetated with last years growth.

All wells were properly labeled and had a legible tag The wells associated with this site are as follows: 115-21814 115-21815 115-21816


There were no violations observed.

2737139 Primary Facility 2018-06-04 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 7.5' below grade with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2833484 Primary Facility 2019-01-30 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of ice and was unable to check for gas. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 1/2/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2600432 787277 2017-05-30 2017-05-30 SWMA 301 Environmental Health & Safety Waste impacted the well pad surface
2600432 787278 2017-05-30 2017-05-30 78.57(a) Environmental Health & Safety Production fluid impacted the well pad surface.
2600432 787279 2017-05-30 2017-05-30 CSL 402(b) Environmental Health & Safety Potential for pollution to impact waters of the commonwealth.