37-115-21746

Well Details

Well ID: 37-115-21746
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Gibson Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 151164
Farm/Lease Name: WEISS M 1
License Status:
Spud Date:
Permit Date: 2014-05-09
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.784119
Longitude: -75.639692

For data sources see[1][2][3]

Well History

Date Event
2014-05-09 New Permit Application
2014-08-08 Performed Spud Operation
2014-10-02 Drilling Completion
2014-10-11 Perforation
2014-10-24 Performed Stimulation
2015-04-09 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-10-23 2014-11-01 7,272 6,619,870 337,253

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 BIO-CLEAR 2000 Clearwater International, LLC Iron Controller / Reducers Polyethylene Glycol Mixture 25322-68-3 60 0.0164439 10239.4
2,2-Dibromo-3-Nitrilopropionamide 10222-01-2 20 0.00548129 3413.15
FE-4 Chemplex, L.C. Iron Controller / Reducers Citric Acid Anhydrous 77-92-9 55 0.000627602 390.801
Water 7732-18-5 55 0.000627602 390.801
MSI-7 National Petrochem Scale Inhibitors Hydrogen Chloride 7647-01-0 100 0.0223635 13925.5
Water Operator Base Carrier Fluid Water 7732-18-5 100 88.6632 55,209,700.0
FR900 Nalco Friction Reducers Proprietary Proprietary 100 0.108401 67500.4
I-22 Nalco Acid Corrosion Inhibitors Formic Acid 64-18-6 60 0.00094601 589.071
Oxyalkylated Fatty Acid Derivative Proprietary 30 0.000473005 294.535
Isopropanol 67-63-0 10 0.000157668 98.1785
2-Mercaptoethyl Alcohol 60-24-2 5 0.00007883 49.0892
Cyclic alkanes Proprietary 5 0.00007883 49.0892
Quaternary ammonium compound Proprietary 30 0.000473005 294.535
Quaternary ammonium compound Proprietary 5 0.00007883 49.0892
Methanol 67-56-1 5 0.00007883 49.0892
Aromatic aldehyde Proprietary 30 0.000473005 294.535
Sand Operator Proppants Silicon Dioxide 14808-60-7 100 10.8894 6,780,700.0
28% Hydrochloric Acid Reagent Scale Dissolver Water 7732-18-5 64.79 0.185625 115587
Hydrogen Chloride 7647-01-0 36.93 0.105806 65884.1

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-10-24 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 CABOT OIL & GAS CORP 535,611.20 47 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 2,959,426.88 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 1,620,946.71 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 1,008,951.43 305 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 1,042,284.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 638,537.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 CABOT OIL & GAS CORP Produced Fluid 2,051.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 3,327.71 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Drill Cuttings 1,433.31 Tons LANDFILL 101247
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 9,298.36 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Drilling Fluid Waste 14.29 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2015 CABOT OIL & GAS CORP Produced Fluid 3,030.05 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 20.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 28.91 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE004
2016 CABOT OIL & GAS CORP Produced Fluid 181.27 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 357.38 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Synthetic Liner Materials 1.89 Tons LANDFILL 101247
2017 CABOT OIL & GAS CORP Waste Water Treatment Sludge 6.47 Tons REUSE (AT WELL PAD)
2017 CABOT OIL & GAS CORP Produced Fluid 276.51 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 150.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017 CABOT OIL & GAS CORP Produced Fluid 108.43 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 37.98 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2018 CABOT OIL & GAS CORP Produced Fluid 383.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 97.99 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 24.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 202.39 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2275283 Primary Facility 2014-05-29 Routine/Complete Inspection No Violations Noted with the pads not staked out and with the LOD not marked, the Department is unable to make a complete evaluation of the site in relation to the identified wetlands. Please stake out the pads and mark off the LOD near the vicinity of the identified wetlands. Also during the inspection, wetland markers were located within what appeared to be the well pad location. Mr. Thompson stated that he did not know why the wetland markers were placed in the well pad vicinity, but suspects that they may have been placed by consultants for the Williams gas pipeline. Please submit a report to the Department explaining why there is a discrepancy in the delineations identified by Cabot and Williams and what the final determination of the wetland delineations is. Once the above mentioned issues are completed, the Department will re-inspect the site.
2276374 Primary Facility 2014-06-04 Routine/Complete Inspection No Violations Noted Inspection conducted to evaluate the siting of a proposed well pad and tank pad in relation to a delineated wetland greater than 1 acre. The inspection is based on Cabot’s submittal of an OG 57 waiver request for their proposed Weiss M . Well Site and Tank Farm. The distance to the wetland is as described. The proposed additional measures described in the application should be adequate in protecting this resource. This field inspection supports the approval of the waiver request. Also present during the inspection was Andrea Mullen, Department Compliance Specialist.
2294138 Primary Facility 2014-08-07 Preoperation Inspection No Violations Noted The Department was on site at the Cabot Weiss, M. Well Site and Tank Farm to conduct a Preoperational Inspection. Well permits that have been issued for this pad are the 1H (115-21746), 2H (115-21747), and the 3H (115-21748). All perimeter BMP’s in place to include red lined additions. The well pad is approximately 95% complete. The tank pad is approximately 75% complete. No violations noted.
2308493 Primary Facility 2014-09-19 Drilling/Alteration No Violations Noted
2472562 Primary Facility 2016-04-06 Routine/Complete Inspection No Violations Noted
2491976 Primary Facility 2016-06-10 Routine/Complete Inspection No Violations Noted
2504037 Primary Facility 2016-07-21 Routine/Complete Inspection No Violations Noted On 7/21/2016, the Department conducted an inspection of the COG Weiss M Well Site. Two of the three wells permitted for this site have been drilled, stimulated, and appear to be in production, the 1H and the 2H. The 3H has not been drilled. Both the well pad and the tank pad are stable and have very good vegetative growth. There was a minor amount of standing water on the well pad near the well heads. A field conductivity test of this water revealed the conductivity to be around 500 milliSiemen/cm³.
2530300 Primary Facility 2016-10-13 Routine/Complete Inspection No Violations Noted
2562346 Primary Facility 2017-02-14 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 15:10p.m., the cellar was full of water and ice with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. There was 819psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 15:40p.m.

2652251 Primary Facility 2017-10-25 Routine/Complete Inspection No Violations Noted At time of inspection.

DLH Energy Service was rigging up a swabbing rig on the 1H. The containment appeared to be in good condition. There was a 500bbl flow back on containment and the containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2751545 Primary Facility 2018-07-12 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 2' below grade in the cellar and there was no bubbling noticed. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2839782 Primary Facility 2019-02-13 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. As the photo's show, the site is snow covered. Overall the site appears to have good stabilization. No E&S issues identified. No violations noted.
2851586 Primary Facility 2019-03-11 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of water and there was no bubbling noticed. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was no gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 3/4/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]