X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-21667

Well Details

Well ID: 37-115-21667
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Jackson Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 150898
Farm/Lease Name: SLOCUM S 3
License Status:
Spud Date:
Permit Date: 2014-02-21
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.831925
Longitude: -75.582008

For data sources see[1][2][3]

Well History

Date Event
2014-02-21 New Permit Application
2014-04-30 Performed Spud Operation
2014-06-13 Drilling Completion
2014-07-19 Perforation
2016-07-29 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-07-18 2014-08-06 7,008 11,486,600 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) TSS Proppant Silica Substrate 14808-60-7 100 11.1364 12,171,100.0
Water Baker Carrier/Base Fluid Water 7732-18-5 100 88.2024 96,397,300.0
Greenhib 679 Chemplex Friction Reducer Proprietary Proprietary 35 0.00864719 9450.61
Glycerine 56-81-5 20 0.00494125 5400.35
Plexbreak 145 Chemplex Non-Emulsifier Methyl Alcohol 67-56-1 15 0.000140739 153.815
Diethanolamine 111-42-2 3 0.00002815 30.763
2-Butoxyethanol 111-76-2 15 0.000140739 153.815
Cocamide Based Surfactant Proprietary 10 0.00009383 102.543
Plexhib 256 Chemplex Acid Inhibitor Propargyl Alcohol 107-19-7 10 0.00008405 91.862
Polyethoxylated Alcohol Surfactant 68951-67-7 30 0.000252157 275.585
Methyl Alcohol 67-56-1 60 0.000504314 551.171
Thiourea/Formaldehyde Copolymer 68527-49-1 30 0.000252157 275.585
C-14 to C-16 Alpha Olefins 64743-02-8 5 0.00004203 45.931
Plexslick 957 Chemplex Friction Reducer Nonionic Surfactants Proprietary 1.5 0.00129218 1412.23
Paraffinic, Naphtehenic Solvent 64742-47-8 30 0.0258435 28244.7
Poly (acrylamide-co-acrylic acid), partial sodium salt 62649-23-4 35 0.0301508 32952.1
Ammonium Chloride 12125-02-9 5 0.00430726 4707.45
Hydrochloric Acid (15%) Reagent Acidizing Hydrochloric Acid 7647-01-0 15 0.0784326 85719.8
Ferriplex 40 Chemplex Iron Control Trisodium Nitrilotriacetate 5064-31-3 40 0.00127056 1388.61
Sodium Hydroxide 1310-73-2 1 0.00003176 34.715
Sodium Sulfate Anhydrous 7757-82-6 2 0.00006353 69.43
Plexcide 15G Chemplex Biocide Didecyl Dimethyl Ammonium Chloride 7173-51-5 3 0.000676103 738.921
Ethanol 64-17-5 3 0.000676103 738.921
Glutaraldehyde 111-30-8 14 0.00315515 3448.3
Alkyl Dimethyl Benzyl Ammonium Chloride 68424-85-1 3 0.000676103 738.921

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 1,546,196.34 219 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 1,573,532.63 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 890,564.13 359 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 748,443.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 636,487.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 1,528.19 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Drill Cuttings 1,384.23 Tons LANDFILL 101247
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 11,292.16 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Drill Cuttings 255.16 Tons LANDFILL THR029
2015 CABOT OIL & GAS CORP Fracing Fluid Waste 7,348.14 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 10,042.04 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 28.42 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 57.70 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE004
2016 CABOT OIL & GAS CORP Produced Fluid 1,331.48 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Waste Water Treatment Sludge 4.28 Tons LANDFILL 301358
2016 CABOT OIL & GAS CORP Produced Fluid 3,136.04 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Synthetic Liner Materials 0.89 Tons LANDFILL 101247
2017 CABOT OIL & GAS CORP Produced Fluid 533.93 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 787.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017 CABOT OIL & GAS CORP Produced Fluid 228.82 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 743.72 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 72.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2018 CABOT OIL & GAS CORP Produced Fluid 456.12 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 239.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 1,082.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2264734 Primary Facility 2014-04-21 Routine/Complete Inspection No Violations Noted . With all of the above mentioned changes that have occurred on the site, the Department requires that Cabot have the design engineer review conditions on the ground and submit a new revised site plan reflecting the site changes along with BMP changes that may be required. This inspection does not qualify as a preoperational inspection. A preoperational inspection will be conducted after the Department reviews the updated site plan.
2266523 Primary Facility 2014-04-29 Preoperation Inspection No Violations Noted The Department was on site on 4/29/14 at the Cabot Slocum S. Well Site to conduct a Preoperational Inspection. Well permits that have been issued for this pad are the 1H (115-21666), 3H (115-21667), and the 5H (115-21668).
2269185 Primary Facility 2014-05-07 Routine/Complete Inspection No Violations Noted The 1H (115-21666), 3H (115-21667), and the 5H (115-21668) wells have been spud and associated conductors set. Contractors are installing newly designed steel rectangular cellars. The cellars, when complete, will be welded to the conductor pipe creating a tight seal. This NOV will be associated with the 1H well permit.
2269676 Primary Facility 2014-05-12 Drilling/Alteration No Violations Noted
2272010 Primary Facility 2014-04-17 Routine/Complete Inspection No Violations Noted The Department was on site on 4/17/14 at the Cabot Slocum S. Well Site to conduct an inspection. Inspection is a follow-up inspection to evaluate how the pad construction is progressing. Well permits that have been issued for this pad are the 1H (115-21666), 3H (115-21667), and the 5H (115-21668). The tank pad is approximately 95% complete. The perimeter BMP’s are in place for this pad. The top soil stock pile and a timber pile that have been installed above the cut slope of the tank pad have not been red lined onto the site plans. The well pad has been cleared and grubbed. Large pools of standing water are present on the well pad location. The site has still not evolved to the point where a pre-operational inspection would be warranted. This inspection does not qualify as a pre-operational inspection. Will re-inspect in near future
2272016 Primary Facility 2014-04-10 Routine/Complete Inspection No Violations Noted The Department was on site on 4/10/14 at the Cabot Slocum S. Well Site to conduct an inspection. Inspection based on Cabot notification that well spudding of this pad is to occur in the very near future, but that site conditions exist which are impeding construction. Well permits that have been issued for this pad are the 1H (115-21666), 3H (115-21667), and the 5H (115-21668). The tank pad is approximately 90% complete. The perimeter BMP’s are in place for this pad. A top soil stock pile and a timber pile have been installed on above the cut slope of the tank pad. Pointed out to George Bishop, GDS foreman, that these features were not on the E&S plans and that they needed to be red lined onto the site plans. The well pad has been cleared, and is currently being grubbed. This inspection does not qualify as a pre-operational inspection. Will re-inspect in near future
2272147 Primary Facility 2014-05-21 Administrative/File Review No Violations Noted This administrative inspection has been created to document Cabot’s response letter related to violations noted in the 4/29/14 NOV/inspection record # 2266507 and the associated enforcement record # 310543. Attached is a copy of the response letter.
2273686 Primary Facility 2014-05-21 Follow-up Inspection No Violations Noted The Department was on site on 5//14 at the Cabot Slocum S. Well Site to conduct a follow up inspection. Well permits that have been issued for this pad are the 1H (115-21666), 3H (115-21667), and the 5H (115-21668).
2285942 Primary Facility 2014-05-21 Routine/Complete Inspection No Violations Noted H&P Drilling Rig #371 is the active rig on location currently drilling the 5H well. The current drilling depth is (4,743.21) feet. Cabot is drilling the lateral section of the well below the intermediate string through the process of water based mud drilling. A white powdery susbstance, was observed spilled to the drilling rig containment. A light tower did not have properly secured containment. The secondary containment berm in the backyard next to the drill cuttings containers was not secured properly. Mr. Wyant contacted rig hands just before the Department left the site to request the white powdery substance spilled to containment be cleaned up immediately and all insecure areas of secondary containment on the location be compleltely secured immediately as well.
2477062 Primary Facility 2016-04-21 Routine/Complete Inspection No Violations Noted
2484893 Primary Facility 2016-05-17 Routine/Complete Inspection No Violations Noted On 5/17/16, the Department conducted an inspection of the COG Slocum, S. Pad located in Jackson Township, Susquehanna County. The inspection was in response to Cabot’s self-reporting of a spill of 12 gallons of antifreeze on the access road of the pad. According to Steve Watson, COG EH&S Specialist at around 7:00 PM, 5/16/16, the previous evening the driver of a low boy who was delivering a piece of machinery noticed that his truck was leaking antifreeze, a line had sprung a leak. J.P. Reilly is the contractor and began the clean-up of the spill. Not sure exactly how much material spilled on the access road as opposed to how much was lost in travel, but after the line was fixed, 12 gallons of antifreeze was added to the reservoir, hence the 12 gallon reporting. Today’s inspection revealed that approximately 3 tons of material has been excavated and placed in a lined roll-off container. According to Jose Fernandez of J.P. Reilly, Resource Environmental had just left, and that they had collected soil sam
2493191 Primary Facility 2016-06-15 Routine/Complete Inspection No Violations Noted
2531815 Primary Facility 2016-10-24 Routine/Complete Inspection No Violations Noted
2563591 Primary Facility 2017-02-21 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:45p.m., the cellar was about a quarter full of ice. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. There was 653psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 14:15p.m.

2684058 Primary Facility 2018-01-08 Routine/Complete Inspection No Violations Noted At time of inspection.

The cellar had snow 5' below grade and there was no gas detected. The (13x9) and (9x5) annuli vent pipes were connected together and venting to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2708531 Primary Facility 2018-03-21 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. No E&S issues were identified. No violations noted.
2779289 Primary Facility 2018-09-25 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2844385 Primary Facility 2019-02-25 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Overall the site appears to have good stabilization. No E&S issues identified. No violations noted.

For data sources see[8]

References