If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-21628 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.958786,"lon":-76.040292,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Choconut Township | |
Operator Name: REPSOL OIL & GAS USA LLC | |
Well Pad ID: 150803 | |
Farm/Lease Name: STICKNEY 07 087 02 A 2H | |
License Status: | |
Spud Date: | |
Permit Date: 2014-01-16 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.958786 | |
Longitude: -76.040292 |
Date | Event |
---|---|
2014-01-16 | New Permit Application |
2014-04-15 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-08-18 | 2014-08-18 | 5,973 | 5,469,620 | 34,000 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | White 40/70 | Trican | Proppant | Crystalline silica: Quartz (SiO2) | 14808-60-7 | 100 | 7.92507 | 4,544,440.0 |
AI-7NR (Acid Inhibitor) | Trican | Acid Inhibitor | Prop-2-yn-1-ol | 107-19-7 | 1 | 0.00001200 | 6.67632 | |
100 Mesh, Bulk (over 20K lbs)* | Trican | Proppant | Crystalline silica: Quartz (SiO2) | 14808-60-7 | 100 | 7.03571 | 4,034,460.0 | |
Water | Customer | Carrier | Water | 7732-18-5 | 100 | 79.6027 | 45,646,200.0 | |
FEAC-20 (Iron Control) | Trican | Iron Control | Citric acid | 77-92-9 | 30 | 0.000824 | 472.684 | |
Acetic acid | 64-19-7 | 45 | 0.001236 | 709.026 | ||||
FR-8 | Trican | Friction Reducer | Ammonium Chloride | 12125-02-9 | 1.5 | 0.001073 | 615.07 | |
Petroleum distillates, dewaxed heavy paraffinic | 64742-65-0 | 8 | 0.005721 | 3280.37 | ||||
Petroleum distillates, hydrotreated heavy paraffinic | 64742-54-7 | 8 | 0.005721 | 3280.37 | ||||
Mineral oil/ light hydrotreated pet. distillate | 64742-47-8 | 28 | 0.020022 | 11481.3 | ||||
3 1/2% HCL | Trican | Carrier | Hydrochloric acid | 7647-01-0 | 3.5 | 0.014263 | 8178.5 | |
AQUCAR DB 5 (Water Treatment Microbiocide) | Trican | Biocide | Sodium Bromide | 7647-15-6 | 1.5 | 0.000394 | 226.135 | |
Polyethylene glycol | 25322-68-3 | 65.2 | 0.017141 | 9829.33 | ||||
Dibromoacetonitrile | 3252-43-5 | 0.5 | 0.000131 | 75.3783 | ||||
2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 5 | 0.001315 | 753.783 | ||||
Other Chemicals | Acrylamide | 79-06-1 | 0 | 0 | 0 | |||
Trade Secret | Proprietary | 0 | 0 | 0 | ||||
Water | 7732-18-5 | 0 | 0 | 0 | ||||
Polyethylene glycol monooleate | 9004-96-0 | 0 | 0 | 0 | ||||
Sorbitol Tetraoleate | 61723-83-9 | 0 | 0 | 0 | ||||
Alkyloxypolyethylene oxyethanol | 84133-50-6 | 0 | 0 | 0 | ||||
Isopropanol | 67-63-0 | 0 | 0 | 0 | ||||
Ammonium Acrylate | 10604-69-0 | 0 | 0 | 0 | ||||
Acrylamide P/W acrylic acid ammonium salt | 26100-47-0 | 0 | 0 | 0 | ||||
Sorbitan monooleate | 1338-43-8 | 0 | 0 | 0 | ||||
Nonionic Surfactant | Proprietary | 0 | 0 | 0 | ||||
Anionic polyacrylamide copolymer | Proprietary | 0 | 0 | 0 | ||||
LSI-21 (Scale Inhibitor) | Trican | Scale Inhibitor | Sodium Salt of Phosphate Ester | 68131-72-6 | 15 | 0.003821 | 2191.34 | |
Acrylic Polymer | 28205-96-1 | 15 | 0.003821 | 2191.34 | ||||
7 1/2% HCL | Trican | Carrier | Hydrochloric acid | 7647-01-0 | 7.5 | 0.006792 | 3894.76 | |
White 30/50 | Trican | Proppant | Crystalline silica: Quartz (SiO2) | 14808-60-7 | 100 | 4.81129 | 2,758,920.0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | REPSOL OIL & GAS USA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | REPSOL OIL & GAS USA LLC | 260,140.00 | 54 | 0.00 | 0 | 0.00 | 0 |
2016 | REPSOL OIL & GAS USA LLC | 896,843.70 | 298 | 0.00 | 0 | 0.00 | 0 |
2017 | REPSOL OIL & GAS USA LLC | 689,579.70 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | REPSOL OIL & GAS USA LLC | 467,004.70 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | REPSOL OIL & GAS USA LLC | 306,542.90 | 358 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | REPSOL OIL & GAS USA LLC | Fracing Fluid Waste | 21,497.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | REPSOL OIL & GAS USA LLC | Fracing Fluid Waste | 1,746.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | REPSOL OIL & GAS USA LLC | Fracturing Fluid Waste | 36.72 Tons | LANDFILL | 100361 |
2014 | REPSOL OIL & GAS USA LLC | Drill Cuttings | 949.09 Tons | LANDFILL | 8-0728-0004/013 |
2015 | REPSOL OIL & GAS USA LLC | Produced Fluid | 925.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | REPSOL OIL & GAS USA LLC | Produced Fluid | 2,000.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | REPSOL OIL & GAS USA LLC | Produced Fluid | 7,165.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | REPSOL OIL & GAS USA LLC | Produced Fluid | 705.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | REPSOL OIL & GAS USA LLC | Produced Fluid | 1,234.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | REPSOL OIL & GAS USA LLC | Produced Fluid | 300.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2017 | REPSOL OIL & GAS USA LLC | Other Oil & Gas Wastes | 240.00 Bbl | REUSE (AT WELL PAD) | |
2017 | REPSOL OIL & GAS USA LLC | Produced Fluid | 609.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | REPSOL OIL & GAS USA LLC | Produced Fluid | 3,952.00 Bbl | REUSE (AT WELL PAD) | |
2018 | REPSOL OIL & GAS USA LLC | Produced Fluid | 500.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | REPSOL OIL & GAS USA LLC | Produced Fluid | 200.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | REPSOL OIL & GAS USA LLC | Produced Fluid | 2,412.00 Bbl | REUSE (AT WELL PAD) | |
2019 | REPSOL OIL & GAS USA LLC | Produced Fluid | 106.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | REPSOL OIL & GAS USA LLC | Produced Fluid | 1,300.00 Bbl | REUSE (AT WELL PAD) | |
2019 | REPSOL OIL & GAS USA LLC | Produced Fluid | 100.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | REPSOL OIL & GAS USA LLC | Other Oil & Gas Wastes | 60.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2252903 | Primary Facility | 2014-03-12 | Preoperation Inspection | No Violations Noted | |
2264852 | Primary Facility | 2014-04-04 | Drilling/Alteration | No Violations Noted | Conductor set |
2266737 | Primary Facility | 2014-04-18 | Drilling/Alteration | No Violations Noted | Conductor set |
2278099 | Primary Facility | 2014-05-31 | Routine/Complete Inspection | No Violations Noted | |
2291279 | Primary Facility | 2014-07-29 | Routine/Complete Inspection | No Violations Noted | |
2309427 | Primary Facility | 2014-09-15 | Incident- Response to Accident or Event | No Violations Noted | Arrived at the site at 12:50 to conduct an inspection related to an estimated (300-400) barrel flowback fluid spill which occurred on 8/9/14. Flowback procedures and natural gas flaring were in progress as the Department arrived to the location. An excavator was in the process of removing the frac tank battery containment liner from the pad surface. The liner was being transferred to a container in preparation for disposal. The primary purpose of the inspection was to evaluate the pad surface beneath the frac tank battery containment due to the spill that occurred on 8/9/14. The pad surface was evaluated in the general vicinity where the spill occurred for evidence of contamination in the in the event of potential compromised liner integrity as the flowback fluid was spilled to containment. Based on visual observations and site evaluations, there is no evidence that the spill on 8/9/14 impacted the surface of the ground on and off the well pad. |
2386093 | Primary Facility | 2015-07-08 | Routine/Complete Inspection | No Violations Noted | |
2440317 | Primary Facility | 2016-01-13 | Incident- Response to Accident or Event | No Violations Noted | The area around the pad was stable and appeared to have all BMPs in place. There was vegetation visible on site through the snow cover.
There are no violations. If there are any questions, please feel free to call me at (570) 346-5539. |
2498588 | Primary Facility | 2016-07-01 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 12:35p.m., the cellar was full of water with no bubbling noticed, the (20x13) vent pipe was open and venting into the atmosphere with no gas detected, the (13x9) vent pipe was open and venting into the atmosphere with no gas detected, the (9x5) vent pipe was open and venting into the atmosphere with no gas detected. There was 913psi on the production casing and 455psi on the production tubing. I took a walk around the location and everything looked OK.
I left the site at 12:50p.m. |
2588478 | Primary Facility | 2017-04-27 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 10:50a.m.
The cellar was full of water with no bubbling noticed. The (20x13) annulus vent pipe was open and venting into the atmosphere with no gas detected, the (13x9) annulus vent pipe was open and venting into the atmosphere with no gas detected, the (9x5) annulus vent pipe was open and venting into the atmosphere with no gas detected. There was 550psi on the production casing and 367psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 11:20a.m. |
2697770 | Primary Facility | 2018-02-15 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was full of water and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2793493 | Primary Facility | 2018-10-22 | Site Restoration | No Violations Noted | I performed a RTNC inspection for for the Stickney well site. The site had its last company E&S inspection on 10/13/2018.
The pad surface area was 180196 square feet. The weather was overcast and 40 degrees. The pad surface and access road were dry. The access road was solid and firm, as was the pad surface. The area was quite rocky. The cut and fill slopes were well vegetated, wherever possible. The rocky nature of the area precludes growth where there is no soil, however wherever there was soil present, there was perennial growth exceeding 70%, as required by the Department. The area was stable and solid and the well was properly labeled. The PCSM infiltration basins were installed and vegetation was adequate on the available soil. There were no violations noted. The well was properly labeled |
2794697 | Primary Facility | 2018-10-25 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was full of water and there was no bubbling noticed. There was a methanol tank and pump (see photo) in containment and the containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |