37-115-21493

Well Details

Well ID: 37-115-21493
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Apolacon Township
Operator Name: REPSOL OIL & GAS USA LLC
Well Pad ID: 150712
Farm/Lease Name: MURPHY 07 075 07 D
License Status: Active
Spud Date: 2014-05-15
Permit Date: 2013-11-08
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.945836
Longitude: -76.098583

For data sources see[1][2][3]

Well History

Date Event
2013-11-08 New Permit Application
2014-03-26 Performed Spud Operation
2014-05-27 Drilling Completion
2014-07-23 Perforation
2014-07-23 Performed Stage 1 of Stimulation
2014-07-23 Performed Stage 2 of Stimulation
2014-07-24 Perforation
2014-07-24 Performed Stage 3 of Stimulation
2014-07-24 Performed Stage 4 of Stimulation
2014-07-24 Performed Stage 5 of Stimulation
2014-07-25 Perforation
2014-07-25 Performed Stage 6 of Stimulation
2014-07-25 Performed Stage 7 of Stimulation
2014-07-25 Performed Stage 8 of Stimulation
2019-01-15 Deviated

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-07-25 2014-07-25 5,542 2,087,300 16,000

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FEAC-20 (Iron Control) Trican Iron Control Acetic acid 64-19-7 45 0.001744 389.964
Citric acid 77-92-9 30 0.001163 259.976
LSI-21 (Scale Inhibitor) Trican Scale Inhibitor Sodium Salt of Phosphate Ester 68131-72-6 15 0.002704 604.462
Acrylic Polymer 28205-96-1 15 0.002704 604.462
3 1/2% HCL Trican Carrier Hydrochloric acid 7647-01-0 3.5 0.013064 2920.89
AQUCAR DB 5 (Water Treatment Microbiocide) Trican Biocide Sodium Bromide 7647-15-6 1.5 0.000386 86.3088
2,2-dibromo-3-nitrilopropionamide 10222-01-2 5 0.001287 287.696
Dibromoacetonitrile 3252-43-5 0.5 0.000129 28.7696
Polyethylene glycol 25322-68-3 65.2 0.016779 3751.56
Water Customer Carrier Water 7732-18-5 100 77.9104 17,419,400.0
White 30/50 Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 5.14021 1,149,260.0
100 Mesh, Bulk (over 20K lbs)* Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 7.63557 1,707,180.0
7 1/2% HCL Trican Carrier Hydrochloric acid 7647-01-0 7.5 0.01742 3894.76
FR-17 (Friction Reducer) Trican Friction Reducer Ethylene Glycol 107-21-1 3 0.000763 170.697
Polyacrylamide Proprietary 30 0.007635 1706.97
Ethoxylated alcohols Proprietary 4 0.001018 227.596
Mineral oil/ light hydrotreated pet. distillate 64742-47-8 28 0.007126 1593.17
AI-7NR (Acid Inhibitor) Trican Acid Inhibitor Prop-2-yn-1-ol 107-19-7 1 0.00001600 3.67198
Other Chemicals Trade Secret Proprietary 0 0 0
Sorbitan monooleate 1338-43-8 0 0 0
Nonionic Surfactant Proprietary 0 0 0
Isopropanol 67-63-0 0 0 0
Polyethylene glycol monooleate 9004-96-0 0 0 0
Acrylamide 79-06-1 0 0 0
Sorbitol Tetraoleate 61723-83-9 0 0 0
Anionic polyacrylamide copolymer Proprietary 0 0 0
Water 7732-18-5 0 0 0
Alkyloxypolyethylene oxyethanol 84133-50-6 0 0 0
Acrylamide P/W acrylic acid ammonium salt 26100-47-0 0 0 0
Ammonium Acrylate 10604-69-0 0 0 0
FR-8 Trican Friction Reducer Ammonium Chloride 12125-02-9 1.5 0.000469 104.878
Mineral oil/ light hydrotreated pet. distillate 64742-47-8 28 0.008756 1957.72
Petroleum distillates, hydrotreated heavy paraffinic 64742-54-7 8 0.002502 559.349
Petroleum distillates, dewaxed heavy paraffinic 64742-65-0 8 0.002502 559.349
White 40/70 Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 8.60229 1,923,320.0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-07-23 1 White 1,243,028 8,316 8,883
2014-07-23 2 White 1,243,028 8,230 8,995
2014-07-24 3 White 1,243,028 8,131 9,086
2014-07-24 4 White 1,243,028 6,882 9,489
2014-07-24 5 White 1,243,028 7,834 8,669
2014-07-25 6 White 1,243,028 7,996 8,620
2014-07-25 7 White 1,243,028 7,141 9,476
2014-07-25 8 White 1,243,028 7,225 8,363

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2015 REPSOL OIL & GAS USA LLC 403,478.00 293 0.00 0 0.00 0
2016 REPSOL OIL & GAS USA LLC 313,499.00 315 0.00 0 0.00 0
2017 REPSOL OIL & GAS USA LLC 215,833.20 363 0.00 0 0.00 0
2018 REPSOL OIL & GAS USA LLC 173,825.30 364 0.00 0 0.00 0
2019 REPSOL OIL & GAS USA LLC 162,811.50 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 17,218.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 REPSOL OIL & GAS USA LLC Fracturing Fluid Waste 28.23 Tons LANDFILL 100361
2014 REPSOL OIL & GAS USA LLC Drill Cuttings 838.07 Tons LANDFILL 8-0728-0004/013
2015 REPSOL OIL & GAS USA LLC Produced Fluid 376.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 REPSOL OIL & GAS USA LLC Produced Fluid 2,910.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 REPSOL OIL & GAS USA LLC Produced Fluid 630.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 REPSOL OIL & GAS USA LLC Produced Fluid 818.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 REPSOL OIL & GAS USA LLC Produced Fluid 80.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 REPSOL OIL & GAS USA LLC Produced Fluid 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2017 REPSOL OIL & GAS USA LLC Produced Fluid 730.00 Bbl REUSE (AT WELL PAD)
2018 REPSOL OIL & GAS USA LLC Produced Fluid 462.00 Bbl REUSE (AT WELL PAD)
2019 REPSOL OIL & GAS USA LLC Produced Fluid 370.00 Bbl REUSE (AT WELL PAD)
2019 REPSOL OIL & GAS USA LLC Other Oil & Gas Wastes 10.00 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2219305 Primary Facility 2013-11-06 Routine/Partial Inspection No Violations Noted OG-57 Waiver Field Inspection.
2231552 Primary Facility 2013-12-23 Preoperation Inspection No Violations Noted
2266747 Primary Facility 2014-04-18 Drilling/Alteration No Violations Noted Conductor set
2285612 Primary Facility 2014-07-10 Routine/Partial Inspection No Violations Noted
2401699 Primary Facility 2015-08-25 Routine/Complete Inspection No Violations Noted
2451947 Primary Facility 2016-02-08 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a Routine Complete inspection of the Murphy Well Pad (ESX13-115-0112). The wells associated with this site are as follows:

115-21492 115-21493.

The site was well vegetated and there were no eroional issues apparent at this time.


There are no violations.

If there are any questions, please feel free to contact me.

2502198 Primary Facility 2016-07-18 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 9:20a.m., the cellar was full of water with no bubbling noticed, the (20x13) vent pipe was open and venting into the atmosphere with no gas detected, the (13x9) vent pipe was open and venting into the atmosphere with no gas detected, the (9x5) vent pipe was open and venting into the atmosphere with no gas detected, there was 427psi on the production casing and 351psi on the production line. I took a walk around the location and everything looked OK.

I left the site at 9:45a.m.

2593797 Primary Facility 2017-05-11 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 9:45a.m.

The cellar was full of water with no bubbling noticed. The (20x13) annulus vent pipe was open and venting into the atmosphere with no gas detected, the (13x9) annulus vent pipe was open and venting into the atmosphere with no gas detected, the (9x5) annulus vent pipe was open and venting into the atmosphere with no gas detected. There was 478psi on the production casing and 483psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 10:10a.m.

2701154 Primary Facility 2018-03-05 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of ice and was unable to check for gas. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2799988 Primary Facility 2018-11-07 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of water and there was no bubbling noticed. The (20x13), (13x9) and (9x5) annuli were venting to the atmosphere. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]