37-115-21445

Well Details

Well ID: 37-115-21445
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Jackson Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 150098
Farm/Lease Name: LONGACRE 2H
License Status:
Spud Date:
Permit Date: 2013-08-27
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.868250
Longitude: -75.631011

For data sources see[1][2][3]

Well History

Date Event
2013-08-27 New Permit Application
2014-07-30 Permit Renewal Application
2015-02-01 Performed Spud Operation
2015-04-25 Drilling Completion
2015-06-10 Perforation
2015-06-10 Performed Stimulation
2015-08-11 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2015-06-10 2015-06-12 6,653 5,220,350 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 EC6486 Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00282074 1496.44
15% HCl Reagent Acid HCL 7647-01-0 15 0.0995502 52812.8
Sand Keane Sand Crystalline Silica, Quartz 14808-60-7 100 17.3962 9,228,950.0
K Bac -1020 WST Biocide Polyethylene glycol 25322-68-3 60 0.00645938 3426.79
2,2-Diobrom-3nirilopropionamide 10222-01-2 20 0.00215313 1142.26
FRA-405 Clearwater Friction Reducer Alcohols, C-12-16, Ethoxylated 68551-12-2 7 0.00413557 2193.98
Ammonium Chloride 12125-02-9 7 0.00413557 2193.98
Petroleum Distillates 64742-47-8 40 0.0236318 12537
Sodium Chloride 7647-14-5 10 0.00590796 3134.26
AI-600 Weatherford Acid Inhibitor Tar bases, quinoline derivs, benzyl chloride-quaternized 72480-70-7 13 0.000215692 114.428
Isopropyl Alchol 67-63-0 7 0.000116142 61.615
Ethoxylated Nonylphenol 68412-54-4 10 0.000165917 88.021
2-Butoxyethanol 111-76-2 7 0.000116142 61.615
Ethylene Glycol 107-21-1 60 0.000995502 528.128
Triethyl Phosphate 78-40-0 7 0.000116142 61.615
Cinnamaldehyde 104-55-2 10 0.000165917 88.021
N,N-Dimethylformamide 68-12-2 40 0.000663668 352.085
Water SWN Water / Produced Water H2O + Disolved Salts 7732-18-5 100 81.8592 43,427,500.0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2015-06-10 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2015 SWN PROD CO LLC 1,220,118.00 183 0.00 0 0.00 0
2016 SWN PROD CO LLC 1,513,898.00 361 0.00 0 0.00 0
2017 SWN PROD CO LLC 833,435.00 364 0.00 0 0.00 0
2018 SWN PROD CO LLC 606,351.00 365 0.00 0 0.00 0
2019 SWN PROD CO LLC 564,960.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2015 SWN PROD CO LLC Fracturing Fluid Waste 23.00 Tons LANDFILL THR029
2015 SWN PROD CO LLC Drilling Fluid Waste 550.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Fracing Fluid Waste 177.50 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Drill Cuttings 1,261.58 Tons LANDFILL 101247
2015 SWN PROD CO LLC Produced Fluid 14,192.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Other Oil & Gas Wastes 41.80 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 2,966.20 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 31.60 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 1,471.40 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 12.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 1,837.60 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 290.80 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 401.20 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Other Oil & Gas Wastes 132.83 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 70.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Produced Fluid 1,203.20 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Other Oil & Gas Wastes 62.23 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Soil Contaminated by Oil 0.06 Tons RESIDUAL WASTE PROCESSING FACILITY 301333
2019 SWN PROD CO LLC Produced Fluid 22.00 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Produced Fluid 462.00 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Soil Contaminated by Oil & Gas Related Spills 0.06 Tons RESIDUAL WASTE PROCESSING FACILITY 301333

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2349651 Primary Facility 2015-03-06 Drilling/Alteration No Violations Noted Visited the Longacre 2H on March 6, 2015 at 10am. Minichi 9 was tripping out of hole on the intermediate string, expected to run casing and pump cement later today. Surface string went well. There were no water shows, 23 barrels of good cement to surface. The floats held and the rig waited 8 hrs before any casing disturbance
2355449 Primary Facility 2015-03-16 Routine/Complete Inspection No Violations Noted Minichi Drilling Rig #9 is on the location currently in the process of drilling the Longacre (Range Unit #43) 5H well at a depth of (1,620) feet. I noticed a rainbow colored petroleum sheen in water on the pad surface where I parked my truck near the production containment and trailers. I pointed out the sheen to Mr. Ruddell upon exiting the Company Man Trailer in preparation to survey the site. Mr. Ruddell order on-site employees to immediately begin the process of removing the sheen in the water via a vacuum truck. I also noticed dark colored fluid on the pad surface. Mr. Ruddell informed me that hammer oil has dripped off the ends of four and a half inch drill pipe to the ground surface of the pad. The drill pipe was not staged on secondary containment. Mr. Ruddell stated that the area of the pad surface impacted from the hammer oil dripping from the drill pipe will be cleaned up immediately with shovels. I noticed the petroleum sheen was no longer visible in the water as I was about to get into my truck and leave the site.
2364166 Primary Facility 2015-04-24 Drilling/Alteration No Violations Noted
2467261 Primary Facility 2016-03-23 Routine/Complete Inspection No Violations Noted
2473358 Primary Facility 2016-04-11 Routine/Complete Inspection No Violations Noted
2491468 Primary Facility 2016-06-08 Routine/Complete Inspection No Violations Noted
2505500 Primary Facility 2016-07-21 Routine/Partial Inspection No Violations Noted
2557661 Primary Facility 2017-01-03 Site Restoration No Violations Noted The Department (Steve Brokenshire and I) was on site at the RU#43-Longacre well site located at 767 Longacres Road Susquehanna, PA to conduct a Restoration Inspection in response to the submittal of a Notice of Termination (NOT). The E&S Inspection Checklist indicated that SRT performed a weekly inspection on 11/17/2016 and that no attention was needed. A note on the E&S Plan stated that the wash rack was removed on 6/7/2016.

The Department noted that Appendix A of the NOT submission indicated that a Subsurface Infiltration Bed was installed on the site as the PCSM BMP. The Department's review of the E&S Plan revealed this PCSM BMP was not included in the ESCGP. The Department contacted SWN and spoke with Justin Thomas who explained that SWN believes that it was included in error. The Department found that this permit was disposed on 10/19/2011 therefore it had expired prior to the NOT receipt date of 10/26/2016.

At this time the Department requests that the operator contact the DEP Northcentral Reg

2585072 Primary Facility 2017-04-18 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:35p.m.

The cellar was set up with a plastic corrugated pipe around the well for inspection access; there was water above the surface casing with no bubbling noticed. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge, the valve going to the production tank was closed. There was 670psi on the production casing and 672psi on the production line. The location is being used as a staging area for the sand trucks for the frac job at the Gaylord pad. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:15p.m.

2585477 Primary Facility 2017-04-21 Routine/Complete Inspection No Violations Noted Todays inspection, 4/18/17 is a routine inspection. The well pad appears to be being utilized as an overflow site for equipment related to the stimulation activities across the street on the Gaylord Pad. Some standing water on pad. Highest conductivity reading observed was 432 micro Siemens. Well site has good stability. No violations observed.
2690142 Primary Facility 2018-02-01 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. The (20x13) and (13x9) annuli were below ice and was unable to check for gas. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2791328 Primary Facility 2018-10-18 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a plastic corrugated pipe around the well for inspection access. There was water .5' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2855249 Primary Facility 2019-03-12 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Overall the site appears to have good stabilization. No E&S issues identified. No violations noted.

For data sources see[9]

References