37-115-21316

Well Details

Well ID: 37-115-21316
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Gibson Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 145684
Farm/Lease Name: BINIEWICZ S 4
License Status:
Spud Date:
Permit Date: 2013-07-11
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.802081
Longitude: -75.655978

For data sources see[1][2][3]

Well History

Date Event
2013-07-11 New Permit Application
2013-08-31 Performed Spud Operation
2013-11-20 Drilling Completion
2014-01-09 Perforation
2014-02-08 Performed Stimulation
2014-05-01 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-02-07 2014-02-20 6,673 8,954,690 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Scaletrol 720 Baker Hughes Scale Inhibitor Calcium Chloride 10043-52-4 5 0.0007626 649.89
Ethylene Glycol 107-21-1 30 0.0045757 3899.34
Other Chemicals Hydrochloric Acid 7647-01-0 0 0.00000880 7.54
Salt Trade Secret 0 0.0045594 3885.48
Sodium Chloride 7647-14-5 0 0.00000460 3.8993
Poly (acrylamide-co-acrylic acid) Trade Secret 0 0.0273565 23312.9
Water 7732-18-5 0 0.0675407 57557.4
Modified Thiorea Polymer 68527-49-1 0 0.00006190 52.78
Potassium Chloride 7447-40-7 0 0.00000760 6.4989
Polyacrylate Trade Secret 0 0.0030505 2599.56
Sorbitan Monooleate Trade Secret 0 0.0045594 3885.48
Formaldehyde 50-00-0 0 0.00000880 7.54
Ethoxylated Alcohol Trade Secret 0 0.0018238 1554.19
Sand, White, 40/70 Baker Hughes Proppant Crystalline Silica (Quartz) 14808-60-7 100 11.0309 9,400,400.0
HCl, 10.1 - 15% Baker Hughes Acidizing Water 7732-18-5 85 0.501417 427301
Hydrochloric Acid 7647-01-0 15 0.0884853 75406.1
Water Operator Carrier Water 7732-18-5 100 87.6127 74,662,400.0
Alpha 1427 Baker Hughes Biocide Glutaraldehyde 111-30-8 30 0.0068352 5824.88
Quaternary Ammonium Compound 68424-85-1 5 0.0011392 970.813
Didecyl Dimethyl Ammonium Chloride 7173-51-5 10 0.0022784 1941.63
Ethanol 64-17-5 5 0.0011392 970.813
Ferrotrol 300L Baker Hughes Iron Control Citric Acid 77-92-9 60 0.0007694 655.651
Sand, White, 100 mesh Baker Hughes Proppant Crystalline Silica (Quartz) 14808-60-7 100 0.611368 521000
FRW-18 Baker Hughes Friction Reducer Petroleum Distillates 64742-47-8 30 0.0273565 23312.9
CI-14 Baker Hughes Corrosion Inhibitor Polyoxyalkylenes Trade Secret 30 0.0002654 226.2
Olefin Trade Secret 5 0.00004420 37.7
Fatty Acids Trade Secret 10 0.00008850 75.4
Methanol 67-56-1 100 0.0008848 754
Propargyl Alcohol 107-19-7 5 0.00004420 37.7

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-02-08 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 1,333,343.22 108 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 2,099,410.73 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 1,330,158.22 365 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 710,503.96 358 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 813,133.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 630,338.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 CABOT OIL & GAS CORP Drilling Fluid Waste 26.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2013 CABOT OIL & GAS CORP Drill Cuttings 1,325.14 Tons LANDFILL 8-0728-0004/013
2014 CABOT OIL & GAS CORP Produced Fluid 3,604.71 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 9,959.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 2,198.73 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 3.29 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 8.97 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE004
2016 CABOT OIL & GAS CORP Produced Fluid 261.94 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 354.80 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Synthetic Liner Materials 0.96 Tons LANDFILL 101247
2017 CABOT OIL & GAS CORP Produced Fluid 279.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 219.65 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017 CABOT OIL & GAS CORP Produced Fluid 148.78 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 13.26 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2018 CABOT OIL & GAS CORP Produced Fluid 535.03 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 111.81 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 22.58 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 523.21 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2240623 Primary Facility 2014-01-30 Drilling/Alteration No Violations Noted
2257240 Primary Facility 2014-03-26 Drilling/Alteration No Violations Noted
2316025 Primary Facility 2014-10-24 Routine/Complete Inspection No Violations Noted The Department conducted an inspection of the Cabot Biniewicz, S. Pad on 10/24/14 in response to a nearby water supply complaint. There are 6 wells drilled and in production on this pad. They are: Biniewicz 1H (115-21313), 2H (115-21314), 3H (115-21315), 4H (115-21316), 5H (115-21317), and the 6H (115-21318). The inspection revealed that the pad was constructed per the plan. There has been no drilling activity on this pad for the last 6 months. No violations were observed at the pad site.
2468339 Primary Facility 2016-03-25 Routine/Complete Inspection No Violations Noted
2513815 Primary Facility 2016-08-25 Routine/Complete Inspection No Violations Noted On 8/25/16, the Department conducted an inspection of the COG Biniewicz, S. Pad located in Gibson Township, Susquehanna County. Last Cabot E&S inspection documented at site as having been conducted on 8/22/16. The entrance to the access road is also the shared driveway and parking area for a house located at the entrance. The access road is paved for about 50’. All six wells have been drilled, stimulated, and appear to be in production. The well pad berms have been eliminated. The tank pad has been reclaimed with what appears to be the tank pad modified material for the pad having been used to create an access road presumably for the landowners use to access his property from the well pad access road. The new owner access road cuts across the old tank pad location and proceeds to the wood line across the diversion swale. A cross culvert pipe has been placed in this swale. The culvert pipe is elevated approximately 1’ from the contour of the diversion swale. Recent heavy rain events suggest this cha
2530208 Primary Facility 2016-10-13 Routine/Complete Inspection No Violations Noted
2530339 Primary Facility 2016-10-12 Routine/Complete Inspection No Violations Noted
2542193 Primary Facility 2016-12-07 Routine/Complete Inspection No Violations Noted The Department was on site, to conduct a Routine Complete Inspection, in response to the submittal of a Restoration Report. The E&S Inspection Log indicated that Stephen P. Opteka conducted the most recent inspection on 12/1/16 and it was a Post Rain Event Inspection.

On site it was noted that what appeared to be new filter sock was situated along the access road and well site and it appeared to be in place for the pipeline. The PCSM/ Site Restoration Plan 1 Map noted that the proposed earthen level spreader has been substitutued for an existing subsurface level spreader.

The tank pad has been removed and is now vegetated.

2552353 Primary Facility 2017-01-12 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:35a.m., the cellar was about three quarters full of water and ice with no bubbling noticed. The (13x9) vent pipe was open and venting into a small plastic tank, the (9x5) vent pipe was open and venting into a small plastic tank. There was 590psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 12:15p.m.

2639959 Primary Facility 2017-09-26 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was containment at the 5H and appeared tubing was recently put in the wells. All the annulus vent pipes were connected together and going to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2655046 Primary Facility 2017-10-26 Site Restoration No Violations Noted This inspection was conducted to confirm Cabot's assessment that the project meets the minimum requirements for permanent stabilization. The Departments determination is that the site meets the requirements for permit termination.
2745580 Primary Facility 2018-06-26 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 2' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2844930 Primary Facility 2019-02-26 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was ice 2' below grade in the cellar and I was unable to check for gas. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was no gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 2/5/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]