If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-21168 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.651458,"lon":-75.932683,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Springville Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 146670 | |
Farm/Lease Name: T KROPA 4 | |
License Status: | |
Spud Date: | |
Permit Date: 2013-03-11 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.651458 | |
Longitude: -75.932683 |
Date | Event |
---|---|
2013-03-11 | New Permit Application |
2013-04-01 | Performed Spud Operation |
2013-05-23 | Drilling Completion |
2013-06-20 | Perforation |
2013-07-02 | Performed Stimulation |
2014-03-17 | DEVIATED |
2016-04-29 | New Permit Application |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-07-02 | 2013-07-13 | 7,577 | 6,795,520 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | FE-100L | FTSI | Iron control | Water | 7732-18-5 | 60 | 0.00106 | 0 |
Citric acid | 77-92-9 | 55 | 0.00097 | 0 | ||||
CS-500 SI | FTSI | Scale inhibitor | Water | 7732-18-5 | 55 | 0.01665 | 0 | |
Sodium chloride | 7647-14-5 | 6 | 0.00182 | 0 | ||||
Sodium Polyacrylate | 9003-04-7 | 5 | 0.00151 | 0 | ||||
Ethylene glycol | 107-21-1 | 10 | 0.00303 | 0 | ||||
CI-150 | FTSI | Acid Corrosion Inhibitor | Fatty Acid Salt | Proprietary | 0.1 | 0.00001000 | 0 | |
Isopropanol | 67-63-0 | 30 | 0.00029 | 0 | ||||
Fatty Acid | Proprietary | 0.1 | 0.00001000 | 0 | ||||
Quaternary ammonium compound | Proprietary | 10 | 0.0001 | 0 | ||||
Organic amine resin salt | Proprietary | 30 | 0.00029 | 0 | ||||
Diethylene glycol | 111-46-6 | 1 | 0.00001000 | 0 | ||||
Water | 7732-18-5 | 5 | 0.00005000 | 0 | ||||
Alkylene Oxide Block Polymer | Proprietary | 10 | 0.0001 | 0 | ||||
Dimethylformamide | 68-12-2 | 10 | 0.0001 | 0 | ||||
Ethylene Glycol | 107-21-1 | 30 | 0.00029 | 0 | ||||
Aromatic aldehyde | Proprietary | 10 | 0.0001 | 0 | ||||
Aliphatic alcohol | Proprietary | 0.1 | 0.00001000 | 0 | ||||
40/70 White | FTSI | Proppant | 40/70 White | 14808-60-7 | 100 | 9.5732 | 0 | |
BIO-3240 | FTSI | Biocide | Sodium Hydroxide | 1310-73-2 | 23 | 0.00704 | 0 | |
Water | 7732-18-5 | 55 | 0.01684 | 0 | ||||
Dazomet (Tetrahydro-3, 5-dimethyl-2H-1, 3, 5-thiadiazine-2-thione. |
533-74-4 | 24 | 0.00735 | 0 | ||||
100 Mesh Sand | FTSI | Proppant | 100 Mesh Sand | 14808-60-7 | 100 | 0.5329 | 0 | |
Hydrochloric Acid (HCl) | FTSI | Acid | Hydrogen Chloride | 7647-01-0 | 15 | 0.08333 | 0 | |
Water | 7732-18-5 | 85 | 0.47218 | 0 | ||||
FRW-200 | FTSI | Friction reducer | Sorbitan Monooleate | 1338-43-8 | 3 | 0.00277 | 0 | |
Alcohols (C12-C16), ethoxylated | 68551-12-2 | 4 | 0.00369 | 0 | ||||
Acrylamide | 79-06-1 | 0.1 | 0.00009000 | 0 | ||||
Alcohols (C10-C16), ethoxylated | 68002-97-1 | 4 | 0.00369 | 0 | ||||
Petroleum distillate hydrotreated light | 64742-47-8 | 26 | 0.02397 | 0 | ||||
Ammonium Chloride | 12125-02-9 | 12 | 0.01106 | 0 | ||||
Proprietary Component | Proprietary | 1.5 | 0.00138 | 0 | ||||
Alkyloxypolyethyleneoxyethanol | 84133-50-6 | 1 | 0.00092 | 0 | ||||
Polyethylene glycol monooleate | 9004-96-0 | 3 | 0.00277 | 0 | ||||
Acrylamide P/W acrylic acid, ammonium salt | 26100-47-0 | 25 | 0.02305 | 0 | ||||
Surfactant | Proprietary | 7 | 0.00645 | 0 | ||||
Ammonium Acrylate | 10604-69-0 | 0.5 | 0.00046 | 0 | ||||
Water | 7732-18-5 | 48 | 0.04426 | 0 | ||||
Sorbitol Tetraoleate | 61723-83-9 | 2 | 0.00184 | 0 | ||||
Alcohols (C12-C14), ethoxylated | 68439-50-9 | 4 | 0.00369 | 0 | ||||
Copolymer of acrylamide and sodium acrylate | 25987-30-8 | 33 | 0.03043 | 0 | ||||
Water | Operator | Carrier | Water | 7732-18-5 | 100 | 89.1826 | 0 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2013-07-02 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | CABOT OIL & GAS CORP | 2,688,512.34 | 162 | 0.00 | 0 | 0.00 | 0 |
2014 | CABOT OIL & GAS CORP | 3,177,369.13 | 362 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 1,564,774.03 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 853,441.35 | 220 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 1,326,013.34 | 297 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 871,572.28 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 572,890.00 | 364 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | CABOT OIL & GAS CORP | Produced Fluid | 5,997.35 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Drill Cuttings | 675.06 Tons | LANDFILL | 101247 |
2013 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 401.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Drill Cuttings | 669.13 Tons | LANDFILL | THR029 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 138.33 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2013 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 4,375.05 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 31.67 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2014 | CABOT OIL & GAS CORP | Produced Fluid | 1,764.76 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 4.33 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 486.17 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 582.12 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 189.85 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 1.27 Tons | LANDFILL | 101247 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 354.28 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 364.32 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 281.20 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 181.73 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 341.18 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 1.50 Tons | LANDFILL | 101247 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2150062 | Primary Facility | 2013-03-21 | Routine/Partial Inspection | No Violations Noted | |
2244568 | Primary Facility | 2014-01-27 | Incident- Response to Accident or Event | No Violations Noted | iolations and details associated with this inspection can be referred to in the T Kropa 3H 1-27-14 inspection report. Permit number is 115-21167. E-facts identification number is 2244547. |
2505862 | Primary Facility | 2016-07-29 | Routine/Complete Inspection | No Violations Noted | |
2513588 | Primary Facility | 2016-08-23 | Drilling/Alteration | No Violations Noted | |
2518583 | Primary Facility | 2016-09-12 | Routine/Complete Inspection | No Violations Noted | |
2525592 | Primary Facility | 2016-10-04 | Routine/Complete Inspection | No Violations Noted | |
2566035 | Primary Facility | 2017-02-22 | Routine/Complete Inspection | No Violations Noted | The Department (Eric Rooney and I) stopped at the well site after finding that the road seemed to have been collecting sediment from vehicles leaving the site earlier in the day as we were en route to a meeting. At the time of our inspection, it was noted that it appeared as though the access road had recently been maintained. Additionally, it appeared as though sediment was no longer leaving the site in the amount it was prior. |
2568349 | Primary Facility | 2017-02-24 | Follow-up Inspection | No Violations Noted | The Department returned to the site to conduct a Follow-Up Inspection concerning the sediment being deposited on State Route 29. Ken Wilson (EHS Foreman -Cabot Completions) was on site and walked along the access road and SR 29 with me. I also met with Larry Fulmer (Frac Superintendent). We walked along the road and found that the sediment mentioned in the Department's 2/22/2017 inspection is still present. Mr. Wilson explained that they have added rock to an area adjacent to the access road and that they have been adding stone to the access road which has built it up.
While on site I explained that any sediment that originated from their site should be collected and returned to within their limits of disturbance (LOD) and stabilized. I requested that they come up with a plan to remove the sediment in a timely and safe manner. Mr. Wilson also explained that they will be relocating a small pile of sediment adjacent to their access road, near the base of the road, and stabilizing it. |
2570099 | Primary Facility | 2017-03-08 | Routine/Complete Inspection | No Violations Noted | I conducted a Follow-Up Inspection in response to Steve Watson's (Cabot) email dated 2/27/17 concerning the clean up of sediment accumulations along SR 29. Photos attached to the email were dated 2/24/17. |
2659484 | Primary Facility | 2017-11-13 | Routine/Complete Inspection | No Violations Noted | Arrived on location at: 10:00. Weather: Winter mix, Cold, ~ 35 degs. A total of (9) wells have been drilled on this pad, the Kropa, T. 1H, 3H, 4H, 5H, 6H, 7H, 8H, 9H and 10H. All wells were in production at time of inspection. All wells (13x9) and (9x5) annuli were open and venting, plumbed to a common vent tank. The 5H, 6H, 7H, 8H, 9H and 10H wells (20x13) annuli were also open and venting, plumbed to a common vent tank. A Gas check performed at the common annular vent tank showed 100% LEL, 100% CH4. -All wells Prod. casing, Static and Differential pressures were being monitored by wireless sending units to onsite Total Flow Control Unit "TFCU". (See individual well insp. reports for pressures.) - TFCU readings were taken off control panel at ~ 10:45. (SP= static press., CP= prod. casing press., DP= differential press.) - 4H: SP= 542 psi, CP= 645 psi., DP= 114 psi. - Overall, wells and pad were found in good condition. No obvious concerns noted at time of inspection. No violations noted. Left location at 11 |
2659877 | Primary Facility | 2017-11-13 | Routine/Complete Inspection | No Violations Noted | |
2834526 | Primary Facility | 2019-01-23 | Routine/Complete Inspection | No Violations Noted | I arrived on site at 1449 to conduct a site restoration inspection in response to a post-drilling site restoration report received from the Operator. The weather was ~38 degrees F and cloudy with moderate freezing rain. There was no activity onsite at the time of inspection. The pad surface was plowed but extremely icy.
Vegetative stabilization requirements were unable to be assessed due to snow cover. Another inspection will have to be conducted when the snow melts in order to determine whether the site meets the post-drilling restoration requirements. No violations were noted. Please contact me with any questions. |
For data sources see[9]