37-115-20722

Well Details

Well ID: 37-115-20722
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Brooklyn Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 148309
Farm/Lease Name: F LIPPINCOTT 2H
License Status:
Spud Date:
Permit Date: 2011-11-18
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.732897
Longitude: -75.822142

For data sources see[1][2][3]

Well History

Date Event
2011-11-18 New Permit Application
2012-09-06 Performed Spud Operation
2013-01-14 Drilling Completion
2013-03-12 Perforation
2013-03-12 Performed Stimulation
2013-05-28 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-03-02 2013-03-11 7,210 6,859,780 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FE-100L FTSI Iron control Water 7732-18-5 60 0.00103 0
Citric acid 77-92-9 55 0.00095 0
CI-150 FTSI Acid Corrosion Inhibitor Dimethylformamide 68-12-2 10 0.0001 0
Fatty Acid Salt Proprietary 0.1 0.00001000 0
Alkylene Oxide Block Polymer Proprietary 10 0.0001 0
Organic amine resin salt Proprietary 30 0.00029 0
Isopropanol 67-63-0 30 0.00029 0
Fatty Acid Proprietary 0.1 0.00001000 0
Diethylene glycol 111-46-6 1 0.00001000 0
Quaternary ammonium compound Proprietary 10 0.0001 0
Water 7732-18-5 5 0.00005000 0
Aromatic aldehyde Proprietary 10 0.0001 0
Aliphatic alcohol Proprietary 0.1 0.00001000 0
Ethylene Glycol 107-21-1 30 0.00029 0
CS-500 SI FTSI Scale inhibitor Water 7732-18-5 55 0.01629 0
Ethylene glycol 107-21-1 10 0.00296 0
Sodium Polyacrylate 9003-04-7 5 0.00148 0
Sodium chloride 7647-14-5 6 0.00178 0
Water Operator Carrier Water 7732-18-5 100 88.1409 0
BIO-3240 FTSI Biocide Water 7732-18-5 55 0.01648 0
Dazomet (Tetrahydro-3, 5-dimethyl-2H-1,
3, 5-thiadiazine-2-thione.
533-74-4 24 0.00719 0
Sodium Hydroxide 1310-73-2 23 0.00689 0
Hydrochloric Acid (HCl) FTSI Acid Hydrogen Chloride 7647-01-0 15 0.08158 0
Water 7732-18-5 85 0.4623 0
FRW-200 FTSI Friction reducer Alkyloxypolyethyleneoxyethanol 84133-50-6 1 0.00094 0
Proprietary Component Proprietary 1.5 0.00141 0
Surfactant Proprietary 7 0.0066 0
Sorbitan Monooleate 1338-43-8 3 0.00283 0
Sorbitol Tetraoleate 61723-83-9 2 0.00188 0
Alcohols (C12-C16), ethoxylated 68551-12-2 4 0.00377 0
Petroleum distillate hydrotreated light 64742-47-8 26 0.0245 0
Alcohols (C12-C14), ethoxylated 68439-50-9 4 0.00377 0
Ammonium Chloride 12125-02-9 12 0.01131 0
Alcohols (C10-C16), ethoxylated 68002-97-1 4 0.00377 0
Acrylamide 79-06-1 0.1 0.00009000 0
Copolymer of acrylamide and sodium acrylate 25987-30-8 33 0.0311 0
Acrylamide P/W acrylic acid, ammonium salt 26100-47-0 25 0.02356 0
Polyethylene glycol monooleate 9004-96-0 3 0.00283 0
Ammonium Acrylate 10604-69-0 0.5 0.00047 0
Water 7732-18-5 48 0.04523 0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2013-03-12 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 3,094,953.96 281 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 2,133,383.62 365 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 1,063,103.26 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 1,231,587.92 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 818,686.63 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 704,525.00 355 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 564,907.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CABOT OIL & GAS CORP Drill Cuttings 110.92 Tons LANDFILL 101247
2013 CABOT OIL & GAS CORP Fracing Fluid Waste 11,827.95 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Fracing Fluid Waste 2,477.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 974.12 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Drill Cuttings 741.88 Tons LANDFILL 101247
2013 CABOT OIL & GAS CORP Drilling Fluid Waste 1,328.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 26.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 5,210.60 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 1,034.66 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 365.56 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 2.93 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 113.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 150.59 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 88.04 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 145.69 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 212.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 52.07 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 CABOT OIL & GAS CORP Synthetic Liner Materials 1.45 Tons LANDFILL 101247
2019 CABOT OIL & GAS CORP Produced Fluid 272.98 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Waste Water Treatment Sludge 0.42 Tons REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2143079 Primary Facility 2012-12-12 Drilling/Alteration No Violations Noted H&P 371 on site. Currently drilling ahead intermediate section of Lippincott 1H. Will be running 9 5/8 Casing tomorrow. Secondary containment in place and in good condition. Will be drilling 2H and 3H on this pad also. No violations observed at this time. Conductor has been set. (94').
2349232 Primary Facility 2015-03-04 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a routine complete inspection of the Lippincott well pad.
2375802 Primary Facility 2015-06-03 Routine/Complete Inspection No Violations Noted
2477628 Primary Facility 2016-04-22 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:50 p.m., the cellar was about a quarter full of water with no bubbling noticed, the (13x9) vent pipe was open and venting to a tank, the (9x5) vent pipe was open and venting to a tank, there was 646psi on the production casing. I took a walk around the location and noticed that the perimeter of the site had been worked on and the vegetation was good, everything else looked OK.

I left the site at 13:20 p.m.

2508887 Primary Facility 2016-06-15 Routine/Complete Inspection No Violations Noted Inspection of the Lippincott well pad in conjunction with the Lippincott 1,2,3,4 Pipeline notice of termination inspection. There were no issues observed on the well pad at the time of the inspection.
2528868 Primary Facility 2016-10-17 Site Restoration No Violations Noted Inspection of the Lippencott F P1 Well Pad in response to a submitted Notice of Termination request for the Erosion and Sedimentation Control Permit.

The site has been stabilized and vegetation was found to be greater than 70% uniform perennial growth. Temporary E&S BMPs have been removed from the site. No E&S problems were observed at the time of the inspection. Post Construction Stormwater Management BMPs appear to be installed properly according to the site restoration plans. The well pad is less than or equal to the size indicated on the site restoration plans.

Based on the site inspection, I recommend this notice of termination be APPROVED.

2639149 Primary Facility 2017-08-08 Routine/Complete Inspection No Violations Noted Today,s inspection, 8/8/17 was conducted as a routine inspection. Entire site is stable. No erosional issues observed. No violations noted.

For data sources see[9]

References