37-115-20699

Well Details

Well ID: 37-115-20699
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Liberty Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 145762
Farm/Lease Name: SADECKI 1 4H
License Status:
Spud Date:
Permit Date: 2011-10-20
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.930764
Longitude: -75.831317

For data sources see[1][2][3]

Well History

Date Event
2011-10-20 New Permit Application
2012-02-10 Performed Spud Operation
2012-03-05 Drilling Completion
2012-04-11 Perforation
2012-04-11 Performed Stimulation
2012-08-17 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-04-16 2012-04-16 5,775 3,738,503

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand- Silica Sand Halliburton Energy Services Proppant Quartz 14808-60-7 100.00 14.12
GBW-30 Breaker Halliburton Energy Services Breaker Carbohydrates 95.00 0.00154000
Hemicellulase enzyme 9012-54-8 15.00 0.00024000
Cla-Web Halliburton Energy Services Clay Control
Proprietary 60.00 0.02
BE-9M Halliburton Energy Services Biocide Methanol 67-56-1 30.00 0.00622000
Tri-n-butyl tetradecyl phosphonium chloride 81741-28-8 10.00 0.00207000
Hydrochloric Acid Halliburton Energy Services Acid Hydrochloric acid 7647-01-0 30.00 0.12
SP Breaker Halliburton Energy Services Breaker Sodium persulfate 7775-27-1 100.00 0.00163000
Water Carrier/Base Fluid Water 100.00 85.68
LP-65 Halliburton Energy Services Scale Inhibitor Ammonium chloride 12125-02-9 10.00 0.00394000
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.01
WG-36 Gelling Agent Halliburton Energy Services Gel
Guar gum 9000-30-0 100.00 0.00187000

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-04-11 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 XPR RESOURCES LLC 152,365.84 95 0.00 0 0.00 0
2013 XPR RESOURCES LLC 489,285.27 354 0.00 0 0.00 0
2014 XPR RESOURCES LLC 377,346.12 365 0.00 0 0.00 0
2015 SWN PROD CO LLC 313,098.04 365 0.00 0 0.00 0
2016 SWN PROD CO LLC 315,246.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 88,961.00 124 0.00 0 0.00 0
2018 SWN PROD CO LLC 165,124.00 275 0.00 0 0.00 0
2019 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 XPR RESOURCES LLC Drilling Fluid Waste 1,061.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC006
2012 XPR RESOURCES LLC Produced Fluid 337.34 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2012 XPR RESOURCES LLC Drilling Fluid Waste 60.43 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 301333
2012 XPR RESOURCES LLC Drill Cuttings 552.79 Tons LANDFILL 100933
2012 XPR RESOURCES LLC Fracing Fluid Waste 2,107.12 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2013 XPR RESOURCES LLC Produced Fluid 501.93 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013 XPR RESOURCES LLC Produced Fluid 100.21 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 XPR RESOURCES LLC Produced Fluid 1,458.96 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2013 XPR RESOURCES LLC Produced Fluid 2,329.45 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 XPR RESOURCES LLC Produced Fluid 1,242.99 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 XPR RESOURCES LLC Produced Fluid 803.35 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 XPR RESOURCES LLC Produced Fluid 396.90 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC010
2013 XPR RESOURCES LLC Produced Fluid 855.14 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2013 XPR RESOURCES LLC Produced Fluid 316.79 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2014 XPR RESOURCES LLC Produced Fluid 238.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 XPR RESOURCES LLC Produced Fluid 3,293.74 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 XPR RESOURCES LLC Produced Fluid 640.31 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 XPR RESOURCES LLC Produced Fluid 2,127.49 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SOUTHWESTERN ENERGY PROD CO Produced Fluid 5,443.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 2,157.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 SWN PROD CO LLC Produced Fluid 2,232.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 141.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 2,732.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 670.00 Bbl REUSE (AT WELL PAD)
2017 SWN PROD CO LLC Produced Fluid 270.00 Bbl REUSE OTHER THAN ROAD SPREADING
2018 SWN PROD CO LLC Other Oil & Gas Wastes 50.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 656.00 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 950.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 2,090.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 304.15 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Other Oil & Gas Wastes 21.74 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2049669 Primary Facility 2012-03-06 Drilling/Alteration No Violations Noted H&P 272. Drilling ahead at depth 5485' on SOBM. 20" set at 120' and cemented to surface. 13 3/8" set at 480' - cement fell back to 80'. Did a 15 bbl top job. 9 5/8" set at 1655' and cemented with 10 bbl cement returns. Drillers log on site and up to date. Secondary containment in place and in good condition. Freeboard in opentops at acceptable levels. No shallow water reported and no significant shallow gas reported. No violations observed.
2343176 Primary Facility 2014-12-17 Routine/Partial Inspection No Violations Noted The Department was on site at the Sadecki well site located at 2899 Franklin Hill Road Hallstead, PA 18822 to conduct a Routine Partial Inspection. The E&S Inspection Log indicated that Casidy Strickland conducted an inspection on 12/12/14 and stated that the site was in good condition. The inspection previous was dated 12/02/14. Operator, please be advised that your inspection frequency does not meet the minimum requirements in 102.4(b)(5)(x). At the time of the inspeciton, the well site was partially snow covered. No obvious E&S issues were found. The site appears to meet temporary stabilization requirements.
2365047 Primary Facility 2015-04-28 Routine/Complete Inspection No Violations Noted
2423054 Primary Facility 2015-11-06 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:55, the cellar was full of gravel, the vent pipe was open and set up with a Taylor plug with a 2000psi pressure gauge which had about 70psi on it, there was no gas detected at the perimeter of the cellar, there was 373psi on the production casing and 265psi on the production line. I took a walk around the location, everything looked OK.
2508842 Primary Facility 2016-05-04 Routine/Complete Inspection No Violations Noted Inspection of the Sadecki well pad in conjunction with the Sadecki Lateral Pipeline - Line 425 notice of termination inspection. There were no issues observed on the well pad at the time of the inspection.
2518355 Primary Facility 2016-09-12 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 9:55a.m., the cellar was full of gravel and no gas was detected. The vent pipe was open and set up with a Taylor plug to check for pressure and a 2000psi pressure gauge that was showing about 90psi on it, there was 274psi on the production casing and 176psi on the production line. I took a walk around the location and everything looked OK.

I left the site at 10:20a.m.

2612748 Primary Facility 2017-07-06 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:45p.m.

The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge and a 2000psi pressure gauge with about 100psi on it. There was 678psi on the production casing and 162psi on the production line. The well was not producing at time of inspection, the main valve going into the GPU was closed. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:15p.m.

2715004 Primary Facility 2018-04-05 Routine/Complete Inspection No Violations Noted At time of inspection.

The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The (9x5) annulus was set up with a 2000psi pressure gauge with 115psi on it. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2783684 Primary Facility 2018-10-03 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was temporarily shut in because of a slope failure on the gas line connecting to the well pad. There were representatives from the Department and SWN to assess the situation and plan for repairs. The Sadecki pad is the only one connected to this section of the gas line, no other pads were shut in. The cellar was full of gravel with water on top and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]

References