37-115-20608

Well Details

Well ID: 37-115-20608
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Lathrop Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 148676
Farm/Lease Name: KERR UNIT B 1H
License Status:
Spud Date:
Permit Date: 2011-07-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.677194
Longitude: -75.835547

For data sources see[1][2][3]

Well History

Date Event
2011-07-28 New Permit Application
2011-09-20 Performed Spud Operation
2011-10-27 Drilling Completion
2013-01-29 Perforation
2013-01-29 Performed Stimulation
2013-05-24 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-02-22 2012-02-22 7,455 937,482
2 2013-01-26 2013-01-26 7,455 3,917,172

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FRW-18 BJ Services Company Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 0.07
Scale Inhibitor - Gyptron T-390 Champion Technologies Scale Inhibitor Methanol 67-56-1 0.00800000
Fresh Water Base Fluid
Fresh Water 100.00 77.98
Biocide - Bactron K 139 Champion Technologies Biocide
Glutaraldehyde 111-30-8 0.03
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1
benzyl-C12-16 alkyldimethyl,chlorides
Ethanol 64-17-5
Hydrochloric Acid 15 BJ Services Company Acid Hydrochloric acid 7647-01-0 0.64
Water 7732-18-5 75.00
Sand (Proppant) BJ Services Company Propping Agent Quartz 14808-60-7 99.90 21.27
2 Gyptron T-390 Champion Technologies Scale Inhibitor
Methanol

67-56-1 10.00
0.01
Biocide - Bactron K 139 Champion Technologies Biocide Ethanol 64-17-5 5.00
Glutaraldehyde 111-30-8 5.00 0.04
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 10.00
FRW-66 Halliburton Energy Services Friction Reducer Hydrotreated Light Distillate
64742-47-8
0.08
Gyptron T-390 Champion Technologies Halliburton Energy Services Scale Inhibitor
Water Base Fluid Fresh Water 100.00 75.00
Hydrochloric Acid 28 Halliburton Energy Services Acid Water

7732-18-5 85
Hydrochloric acid 7647-01-0 0.50
Sand (Proppant) Halliburton Energy Services Propping Agent Quartz 14808-60-7 99.90 25.00

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2013-01-29 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 116,385.00 33 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 2,400,835.00 313 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 2,034,866.00 359 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 1,283,578.89 362 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 1,031,177.48 316 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 799,340.52 364 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 633,456.80 282 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 558,963.96 307 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHIEF OIL & GAS LLC Drill Cuttings 1,651.01 Tons LANDFILL 301626
2012 CHIEF OIL & GAS LLC Fracing Fluid Waste 5,118.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHIEF OIL & GAS LLC Produced Fluid 225.70 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Fracing Fluid Waste 937.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Produced Fluid 2,665.30 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Fracturing Fluid Waste 5.33 Tons RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC006
2014 CHIEF OIL & GAS LLC Produced Fluid 97.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHIEF OIL & GAS LLC Produced Fluid 200.91 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHIEF OIL & GAS LLC Fracturing Fluid Waste 40.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016 CHIEF OIL & GAS LLC Produced Fluid 389.51 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHIEF OIL & GAS LLC Produced Fluid 71.02 Bbl REUSE (AT WELL PAD)
2017 CHIEF OIL & GAS LLC Produced Fluid 15.34 Bbl REUSE OTHER THAN ROAD SPREADING
2018 CHIEF OIL & GAS LLC Produced Fluid 73.33 Bbl REUSE (AT WELL PAD)
2018 CHIEF OIL & GAS LLC Produced Fluid 216.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 CHIEF OIL & GAS LLC Produced Fluid 150.47 Bbl REUSE (AT WELL PAD)
2019 CHIEF OIL & GAS LLC Synthetic Liner Materials 4.17 Tons LANDFILL 301358

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2011524 Primary Facility 2011-10-13 Drilling/Alteration No Violations Noted DEP on site at 14:30. Patterson Rig 251. Checked drillers log - needs to be updated with gas/water show data. Walked site - secondary containment in place and in good condition. Cement reports show good returns on both 13 3/8" and 9 5/8".
2018697 Primary Facility 2011-11-07 Routine/Complete Inspection Pending DEP on site 14:00. Crews on site cleaning up pad. Patterson 251 moving to Squire Unit B. Walked site. Crews picking up mats and moving rest of equipment off location. Inspected cellar - can hear gas venting through one of the vents. Cupped hand over vent - pressure buildup exists. Can not determine which annulus it is. REquest Operator to identify and report to DEP with findings.
2020622 Primary Facility 2011-11-09 Routine/Complete Inspection No Violations Noted
2031194 Primary Facility 2012-01-03 Follow-up Inspection Pending DEP -Steve Watson, Kevin Costello and Andrea Schmid on site 11 am. Meth with Rich Adams and other Chief personnel to investigate backside pressures on well. While on site, Operator installed 100 lb gauge on 9 x 13" annulus, and 100 lb gauge on 9 x 5" annulus. No noticeable increase in pressure on 9 x 13" while on site. Operator going to monitor 9 x 13" for 24 hours to see if any buildup. After 21 mins...SIP on 9 x 5" was 28 psi. Operator will continue venting 9 x 5" to poly tank. Once 24 hr shut in test complete, Operator will report data to DEP. Inspection results Pending at this time.
2310439 Primary Facility 2014-10-02 Drilling/Alteration No Violations Noted
2445793 Primary Facility 2016-01-25 Routine/Complete Inspection No Violations Noted Routine inspection of the Kerr Unit B Well Pad prior to the start of fracking activities of the 2H and 3H wells. I was accompanied by Jon Sassi, DEP Environmental Protection Specialist. During the inspection we met Water Foreman, Ralph Larsen, and Company Man, Bret Fowler, both of Chief. The Department received stimulation notices for both wells on January 22, 2016. At the time of the inspection, fracking continues on the Kerr Unit 4H well.

The site is stable with no observable E & S issues at the time of the inspection. Post Construction Stormwater Management BMPs are installed and appear to functioning properly. Containment was in place around the water and brine tanks, etc, and crews were at work constructing the remaining containment and building the heater houses for the water and brine tanks.

2473919 Primary Facility 2016-03-24 Routine/Complete Inspection No Violations Noted Routine inspection of the Kerr Unit B Well Pad in conjunction with the Notice of Termination inspection of the Kerr B Lateral pipeline. Crews were removing containment and equipment from the recent fracking of the 2H and 3H wells. Much of the surface of the pad was still covered but no issues were observed. The Department will visit the pad at a later date for a more detailed post-frack inspection of the pad.
2715941 Primary Facility 2018-04-06 Site Restoration No Violations Noted This inspection was conducted to confirm Chief's assessment that the project meets the minimum requirements for permit termination. The one infiltration berm for this pad has been installed. The Department’s determination is that the site meets the requirements for permit termination. I recommend the NOT be approved.