37-115-20590

Well Details

Well ID: 37-115-20590
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Bridgewater Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 148222
Farm/Lease Name: DERIANCHO 4
License Status:
Spud Date:
Permit Date: 2011-05-31
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.799497
Longitude: -75.852414

For data sources see[1][2][3]

Well History

Date Event
2011-05-31 New Permit Application
2011-06-20 Performed Spud Operation
2011-10-10 Drilling Completion
2011-11-06 Perforation
2011-11-06 Performed Stimulation
2012-06-22 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-01-02 2012-01-02 6,824 7,352,898

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 AI-2 Superior Well Services Corrosion Inhibitor Isopropanol 67-63-0 30.00 0.00029000
Proprietary Component 7.00 0.00007000
Propargyl alcohol 107-19-7 30.00 0.00029000
2-Butoxyethanol 111-76-2 30.00 0.00029000
LSG-1 Liquid Slurry Gel Superior Well Services Gelling Agent Iso-Alkanes/n-Alkanes 60.00 0.00016000
Polysaccharide Blend 60.00 0.00016000
XL-8 Superior Well Services Crosslinking Agent Proprietary Component 7.00 0.00001000
Ethylene glycol 107-21-1 30.00 0.00004000
15 HCl Superior Well Services Acid Package Hydrochloric acid 7647-01-0 15.00 0.08
EB-4L Superior Well Services Gel Breaker Ethylene glycol 107-21-1 30.00 0.00
KR-153SL Superior Well Services Biocide Ethylene glycol 107-21-1 1.00 0.00028000
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00550000
Diethylene glycol 111-46-6 3.50 0.00096000
Polyethylene glycol 25322-68-3 50.00 0.01
Sand (Proppant) Proppant 100.00 11.54
Super TSC Superior Well Services Scale Control Anionic polymer 15.00 0.00380000
2-Phosphonobutane-1,2,4-tricarboxylic acid, potassium salt 93858-78-7 15.00 0.00380000
1,2-Propylene glycol 57-55-6 40.00 0.01
Anionic copolymer 15.00 0.00380000
Water Carrier/Base Fluid 100.00 88.26
WFR-3B Superior Well Services Friction Reducer Poly(oxy-1,2-ethanediyl), .alpha.,.alpha.'-[[(9Z)-9-octadecenylimino]di-2,1-ethanediyl]bis[.omega.-hydroxy
-
26635-93-8 5.00 0.00382000
1,2-Propylene glycol 57-55-6 15.00 0.01
Distillates, petroleum, hydrotreated light 64742-47-8 50.00 0.03
Ethoxylated alcohol blend 15.00 0.01

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2011-11-06 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 2,868,239.52 330 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 2,033,094.64 365 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 1,423,071.68 359 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 855,415.16 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 1,002,676.82 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 777,876.69 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 706,859.00 344 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 643,319.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CABOT OIL & GAS CORP Drilling Fluid Waste 1,043.67 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CABOT OIL & GAS CORP Drill Cuttings 0.76 Tons LANDFILL 101534
2011 CABOT OIL & GAS CORP Drill Cuttings 41.42 Tons LANDFILL 101247
2011 CABOT OIL & GAS CORP Drill Cuttings 1,408.20 Tons LANDFILL THR029
2011 CABOT OIL & GAS CORP Drill Cuttings 0.44 Tons LANDFILL 100081
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 2.16 Tons LANDFILL 101534
2012 CABOT OIL & GAS CORP Basic Sediment 21.17 Bbl LANDFILL 101534
2012 CABOT OIL & GAS CORP Produced Fluid 3,726.23 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Basic Sediment 7.71 Bbl LANDFILL THR029
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 31.95 Tons LANDFILL 100081
2012 CABOT OIL & GAS CORP Fracing Fluid Waste 10,405.59 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 28.51 Tons LANDFILL 100945
2012 CABOT OIL & GAS CORP Basic Sediment 16.81 Bbl LANDFILL 100081
2012 CABOT OIL & GAS CORP Produced Fluid 29.68 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 593.59 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 42.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 549.05 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 914.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 365.74 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 28.34 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 181.97 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 166.53 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 168.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 92.62 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 CABOT OIL & GAS CORP Produced Fluid 300.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 200.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 202.62 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2005259 Primary Facility 2011-09-21 Drilling/Alteration No Violations Noted H&P 371. Just set 13 3/8". Bumped plud at 3:30 am. Will drill 9 5/8" on water then air to KOP, then drill alteral on SOBM. Walked site with company man. Secondary containment in place and good condition. Asked Company Man to pump out spill pan under fuel tank manifold. 13 3/8" set at 575' with 28 bbls cement returns reported.
2368094 Primary Facility 2015-05-07 Routine/Complete Inspection No Violations Noted
2440245 Primary Facility 2016-01-13 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:50 p.m., the cellar was full of ice and snow, the (13x9) vent pipe was open and venting to a tank, the (9x5) vent pipe was open and venting to a tank, there was 705psi on the production casing. I took a walk around the location and everything looked OK.

I left the site at 13:15 p.m.

2440750 Primary Facility 2015-09-08 Routine/Complete Inspection No Violations Noted Inspection in conjunction with the notice of termination inspection of the Vandermark Pipeline. No issued observed at the time of the inspection.
2540527 Primary Facility 2016-11-30 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:45p.m., the cellar was about three quarters full of water with no bubbling noticed. The (13x9) vent pipe was open and venting into a small poly tank, the (9x5) vent pipe was open and venting into a small poly tank. There was 555psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 13:20p.m.

2627713 Primary Facility 2017-08-18 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 14:05p.m.

The cellar was full of water with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. All the annulus vent pipes were connected to one pipe going into the same tank. There was 502psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:35p.m.

2714138 Primary Facility 2018-04-03 Routine/Complete Inspection No Violations Noted I inspected the Deriancho well pad for RTNC inspection. The well pad was approximately 80,000 sq. ft. The cut slope and well pad had greater than 70% perennial vegetative cover. There were no temporary BMPs remaining on site. There were two wells associated with this site:

115-20484 115-20590.

There were no erosional issues noted.

There were no violations observed.

2737965 Primary Facility 2018-06-05 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 1' below grade in the cellar and there was no bubbling noticed. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2833669 Primary Facility 2019-01-30 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of snow and ice, I was unable to check for gas. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 1/2/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]