37-115-20567

Well Details

Well ID: 37-115-20567
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Springville Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 150750
Farm/Lease Name: JOHN LOPATOFSKY 1V
License Status:
Spud Date:
Permit Date: 2011-05-11
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 41.653575
Longitude: -75.867589

For data sources see[1][2][3]

Well History

Date Event
2011-05-11 New Permit Application
2011-07-09 Performed Spud Operation
2011-08-19 Drilling Completion
2011-10-09 Perforation
2011-10-09 Performed Stimulation
2012-02-06 NEWLY DRILLED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-10-10 2011-10-10 8,786 682,836

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) Proppant 100.00 12.42
FRW-200 Frac Tech Services (FTS) Friction Reducer No hazardous ingredients 100.00 0.10
Water Carrier/Base Fluid 100.00 87.41
CS-500 SI Frac Tech Services (FTS) Scale Inhibitor No hazardous ingredients 100.00 0.04
ICI-3240 Frac Tech Services (FTS) Antibacterial Agent Sodium hydroxide 1310-73-2 4.00 0.00150000
Tetrahydro-3,5-dimethyl,2H-1,3,5-thiadiazine-2-thione 533-74-4 24.00 0.00898000

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2011-10-09 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 90,105.00 140 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 91,049.00 341 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 6,187.25 98 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 11,390.95 352 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 11,322.58 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 28,477.94 279 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 8,606.00 177 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 8,092.00 168 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CABOT OIL & GAS CORP Drilling Fluid Waste 1,508.95 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CABOT OIL & GAS CORP Drill Cuttings 0.83 Tons LANDFILL 101534
2011 CABOT OIL & GAS CORP Drill Cuttings 423.24 Tons LANDFILL 101247
2011 CABOT OIL & GAS CORP Drill Cuttings 59.85 Tons LANDFILL 101615
2011 CABOT OIL & GAS CORP Drill Cuttings 1,370.25 Tons LANDFILL THR029
2011 CABOT OIL & GAS CORP Drill Cuttings 3.31 Tons LANDFILL 100081
2011 CABOT OIL & GAS CORP Fracing Fluid Waste 3,520.54 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CABOT OIL & GAS CORP Fracturing Fluid Waste 11.11 Tons LANDFILL 100081
2012 CABOT OIL & GAS CORP Produced Fluid 269.64 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Basic Sediment 2.70 Bbl LANDFILL THR029
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 2.13 Tons LANDFILL 100081
2012 CABOT OIL & GAS CORP Fracing Fluid Waste 469.93 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CABOT OIL & GAS CORP Produced Fluid 149.60 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 116.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 1,779.43 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 583.52 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 17.49 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 43.74 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 2.06 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 0.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1989205 Primary Facility 2011-07-20 Drilling/Alteration No Violations Noted Pioneer 63. Call from operator there is a presence of bubbling near wall of tin-horn. Only conductor set. Had 35u of gas at 92'. Observed intermittent bubbles coming up to surface on western wall of tin-horn. Will revisit site tomorrow with gas meter to determine if gas. Conductor and cellar floor cemented.
1989208 Primary Facility 2011-07-21 Follow-up Inspection No Violations Noted Pioneer 63. Follow up on presence of bubbling in cellar on west wall of tin-horn. At time of inspection, bubbling has ceased. Plan to start drilling later today. Operator will monitor cellar conditions and report to DEP any changes in conditions.
2000263 Primary Facility 2011-08-03 Drilling/Alteration No Violations Noted Pioneer 63. Drilling depth 7520'. Cored from 7295 to 7520'. Proposed depth 8665'. Inspected cellar - no bubbling observed. TOH - first core. Walked around location - secondary containment in place and in good condition. Mentioned to Company Man ti inspect drum storage container on backside of pad. Appears to be leaking. It's on containment...DEP will follow up. Conductor set at 90'. 13 3/8" set at 465' (30bbls return), 9 5/8" set at 1505' (50 bbl returns).
2000359 Primary Facility 2011-08-17 Drilling/Alteration No Violations Noted Pioneer 63. BJ on site to flush out stack. Hooked up incorrectly to A-section and collapsed sectionand collapsed 9 5/8" casing. Operator removing well head and will assess damage. If possible, will cut off section of bad casing. If necessary, will washover 9 5/8" casing and remove top joint of pipe.
2006590 Primary Facility 2011-07-21 Routine/Complete Inspection No Violations Noted
2006925 Primary Facility 2011-08-24 Routine/Complete Inspection No Violations Noted
2006990 Primary Facility 2011-08-01 Routine/Complete Inspection No Violations Noted
2007010 Primary Facility 2011-08-25 Follow-up Inspection Violation(s) Noted NERO EC&B Act 2 ROL granted 12/1/11, MBC data clean-up 3/27/15.
2282165 Primary Facility 2014-06-23 Incident- Response to Accident or Event No Violations Noted Arrived at the site at 13:05 in response to a (7) gallon spill of a hydrochloric acid. Cabot contacted the Department at 5:30 PM on 6-18-14 to report they lost (7) gallons of hydrochloric acid on the Pad and it has been neutralized and cleaned up. Hydraulic fracturing operations were in progress during the inspection. Halliburton is the subcontractor at the location conducting the operations. A Halliburton truck containing hydrochloric acid, which is used during well stimulation procedures, lost acid out of a hatch on top of the truck while en route to move the truck from near the access road of the Pad to the truck storage area. Apparently, as the truck stopped, acid sloshed back and forth in the truck, eventually escaping either an open, loose or not completely closed hatch on the top of the truck. The acid flowed down the side of the truck to the ground the surface of the Well Pad.
2530968 Primary Facility 2016-10-20 Site Restoration No Violations Noted Inspection of the Lopatofski J P1 in response to a submitted Notice of Termination request for the Erosion and Sedimentation Control Permit. EPS, Jon Sassi, was also present on this inspection.

The site has been stabilized and vegetation was found to be greater than 70% uniform perennial growth. Temporary E&S BMPs have been removed from the site. No E&S problems were observed at the time of the inspection. Post Construction Stormwater Management BMPs appear to be installed properly according to the site restoration plans. The well pad is less than or equal to the size indicated on the site restoration plans.

Based on the site inspection, I recommend this notice of termination be APPROVED.

Jon and I also conducted a general inspection of the pad. Signs and labeling appeared to be correct. The mailbox contained the required items. There were no apparent issues with containment. Conductivity readings of water on the pad were of no concern.

2583323 Primary Facility 2017-04-04 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a Routine Complete Inspection of the well site. The E&S Inspection Log showed that Paul Hoven conducted the final E&S Inspection on 2/14/17, it was a post rain event inspection. The site appears to be stable. Being that the ESCGP for this site has been terminated, please remove the E&S Controls.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2007010 621315 08/25/2011 2011-08-25 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative NERO EC&B Act 2 ROL granted 12/1/11, MBC data clean-up 3/27/15.
2007010 621316 08/25/2011 2011-08-25 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used Administrative 402 NERO EC&B Act 2 ROL granted 12/1/11, MBC data clean-up 3/27/15.
2007010 621317 08/25/2011 2011-08-25 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety 6018.610 NERO EC&B Act 2 ROL granted 12/1/11, MBC data clean-up 3/27/15.

For data sources see[9]