If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 37-115-20526 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.917217,"lon":-75.832708,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Susquehanna | |
| Municipality: Franklin Township | |
| Operator Name: SWN PROD CO LLC | |
| Well Pad ID: 148544 | |
| Farm/Lease Name: HOLLENBECK 3H | |
| License Status: | |
| Spud Date: | |
| Permit Date: 2011-03-02 | |
| Well Type: GAS | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Conservation: No | |
| Latitude: 41.917217 | |
| Longitude: -75.832708 |
| Date | Event |
|---|---|
| 2011-03-02 | New Permit Application |
| 2011-03-11 | Performed Spud Operation |
| 2011-05-25 | Drilling Completion |
| 2011-12-18 | Perforation |
| 2011-12-18 | Performed Stimulation |
| 2012-04-30 | DEVIATED |
For data sources see[4]
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 2011-12-18 | 2011-12-18 | 5,751 | 3,645,532 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | WG-36 Gelling Agent | Halliburton Energy Services | Gel | |||||
| Guar gum | 9000-30-0 | 100.00 | 0.00154000 | |||||
| Water | Carrier/Base Fluid | Water | 100.00 | 87.04 | ||||
| Sand- Silica Sand | Halliburton Energy Services | Proppant | Quartz | 14808-60-7 | 100.00 | 12.76 | ||
| FR-66 Friction Reducer | Halliburton Energy Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.01 | ||
| Hydrochloric Acid | Halliburton Energy Services | Acid | Hydrochloric acid | 7647-01-0 | 30.00 | 0.13 | ||
| GBW-30 Breaker | Halliburton Energy Services | Breaker | ||||||
| Hemicellulase enzyme | 9012-54-8 | 15.00 | 0.00022000 | |||||
| Carbohydrates | 95.00 | 0.00139000 | ||||||
| Cla-Web | Halliburton Energy Services | Clay Control | ||||||
| Proprietary | 60.00 | 0.02 | ||||||
| BE-9M | Halliburton Energy Services | Biocide | ||||||
| Tri-n-butyl tetradecyl phosphonium chloride | 81741-28-8 | 10.00 | 0.00096000 | |||||
| Methanol | 67-56-1 | 30.00 | 0.00289000 | |||||
| SP Breaker | Halliburton Energy Services | Breaker | Sodium persulfate | 7775-27-1 | 100.00 | 0.00146000 | ||
| LP-65 | Halliburton Energy Services | Scale Inhibitor | Ammonium chloride | 12125-02-9 | 10.00 | 0.00374000 |
For data sources see[5]
| Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
|---|---|---|---|---|---|
| 2011-12-18 | 0 | 0 | 0 |
For data sources see[6]
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2011 | XPR RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2012 | XPR RESOURCES LLC | 82,144.54 | 182 | 0.00 | 0 | 0.00 | 0 |
| 2013 | XPR RESOURCES LLC | 245,146.51 | 328 | 0.00 | 0 | 0.00 | 0 |
| 2014 | XPR RESOURCES LLC | 179,253.57 | 364 | 0.00 | 0 | 0.00 | 0 |
| 2015 | SWN PROD CO LLC | 155,431.61 | 361 | 0.00 | 0 | 0.00 | 0 |
| 2016 | SWN PROD CO LLC | 175,042.00 | 365 | 0.00 | 0 | 0.00 | 0 |
| 2017 | SWN PROD CO LLC | 48,825.00 | 171 | 0.00 | 0 | 0.00 | 0 |
| 2018 | SWN PROD CO LLC | 24,490.00 | 271 | 0.00 | 0 | 0.00 | 0 |
| 2019 | SWN PROD CO LLC | 9,902.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
| Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|---|
| 2011 | XPR RESOURCES LLC | Drilling Fluid Waste | 174.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
| 2013 | XPR RESOURCES LLC | Produced Fluid | 490.83 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
| 2013 | XPR RESOURCES LLC | Produced Fluid | 1,300.57 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
| 2013 | XPR RESOURCES LLC | Produced Fluid | 1,664.90 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2013 | XPR RESOURCES LLC | Produced Fluid | 954.62 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
| 2013 | XPR RESOURCES LLC | Produced Fluid | 1,024.96 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
| 2013 | XPR RESOURCES LLC | Produced Fluid | 401.41 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
| 2013 | XPR RESOURCES LLC | Produced Fluid | 612.90 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC010 |
| 2014 | XPR RESOURCES LLC | Produced Fluid | 398.75 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
| 2014 | XPR RESOURCES LLC | Produced Fluid | 2,195.30 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
| 2014 | XPR RESOURCES LLC | Produced Fluid | 612.95 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
| 2014 | XPR RESOURCES LLC | Produced Fluid | 981.14 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2015 | SOUTHWESTERN ENERGY PROD CO | Produced Fluid | 3,163.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016 | SWN PROD CO LLC | Produced Fluid | 1,050.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
| 2016 | SWN PROD CO LLC | Produced Fluid | 1,531.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 13.75 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2017 | SWN PROD CO LLC | Produced Fluid | 550.25 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2017 | SWN PROD CO LLC | Produced Fluid | 137.50 Bbl | REUSE (AT WELL PAD) | |
| 2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 40.00 Bbl | REUSE (AT WELL PAD) | |
| 2018 | SWN PROD CO LLC | Produced Fluid | 1,128.25 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 50.36 Bbl | SURFACE IMPOUNDMENT | 826342 |
| 2018 | SWN PROD CO LLC | Produced Fluid | 716.50 Bbl | REUSE (AT WELL PAD) | |
| 2018 | SWN PROD CO LLC | Produced Fluid | 415.75 Bbl | SURFACE IMPOUNDMENT | 826342 |
| 2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 194.40 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2019 | SWN PROD CO LLC | Produced Fluid | 57.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC035 |
| 2019 | SWN PROD CO LLC | Produced Fluid | 793.25 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 5.44 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2019 | SWN PROD CO LLC | Produced Fluid | 30.00 Bbl | REUSE (AT WELL PAD) | |
| 2019 | SWN PROD CO LLC | Produced Fluid | 451.50 Bbl | SURFACE IMPOUNDMENT | 826342 |
For data sources see[8]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 1974888 | Primary Facility | 2011-05-11 | Drilling/Alteration | No Violations Noted | Depth of drilling = 431'. Surface casing (13 3/8") set at 431'. Set with 383 sks of 15.2 lb cement with 1.36 Y. Reported 40 bbls return. 20" conductor set at 140'. Bumped plug at 21:15 on 5/10/11. Walked site with Rig mgr. David Phillips. Discussed fixing and maintaining secondary containment. Commented on flare stack height. Height was approximately 8' high which appeared to be low and potentially unsafe. Looked at area of previous spill near sand trap under shakers. Appears spill has been adequately cleaned at this time and this violation has been corrected. Fill slope also stabilized. Inspected cellar for bubbling - none observed. |
| 1987226 | Primary Facility | 2011-07-07 | Follow-up Inspection | Pending | Drilling complete. Inspected cellar. Fluid above 9 5/8" & conductor. Observed steady stream of bubbling along inside wall of conductor on eastern side. Cannot see source of bubbling due to level of fluid. Further investigation required. Gas well completions report ultimately reviewed 3/2/12. Integrity evaluation of gas well done during GMI investigation found no viols. GMI closed 4/24/13 via non-impact determ ltr. |
| 1987346 | Primary Facility | 2011-07-07 | Routine/Complete Inspection | No Violations Noted | |
| 1989187 | Primary Facility | 2011-07-20 | Follow-up Inspection | Violation(s) Noted | Follow up on evidence of bubbling around well head. Observed bubbling in between 9 5/8" and 13 3/8" casing. Minor bubbling outside of 13 3/8" casing. Tagged TOC in 9 5/8 annulus at @ 3' below top of casing. TOP cement tagged at @ 12' below casing on 13 3/8" annulus. Violations for defective cement and no well tag cited. Gas well completions report ultimately reviewed 3/2/12. Integrity evaluation of gas well done during GMI investigation found no viols. GMI closed 4/24/13 via non-impact determ ltr. |
| 2005445 | Primary Facility | 2011-09-15 | Routine/Complete Inspection | No Violations Noted | |
| 2006739 | Primary Facility | 2011-09-22 | Routine/Complete Inspection | No Violations Noted | |
| 2007688 | Primary Facility | 2011-09-23 | Follow-up Inspection | No Violations Noted | |
| 2053521 | Primary Facility | 2012-03-20 | Routine/Complete Inspection | Pending | Inspected current status and condition of well. Well has been completed and fracced. Well is not online. Observed minor bubbling on 9 x 13 3/8" annulus at the surface. No other bubbling oberved at the time of this inspection. A Mercer service rig is on site and a small crew of workers. DEP will follow up with Operator on condition of well. Gas well completions report ultimately reviewed 3/2/12. Integrity evaluation of gas well done during GMI investigation found no viols. GMI closed 4/24/13 via non-impact determ ltr. |
| 2066945 | Primary Facility | 2012-05-10 | Drilling/Alteration | No Violations Noted | At time of inspection- Service Rig set up on 1H - preparing wells for production. Inspected cellar - intermittent bubbling observed on outside of 9 5/8" casing. (minor bubbling about every second). Well is shut in - not online yet. Pipleine crews working nearby at time of inspection. |
| 2278322 | Primary Facility | 2014-06-12 | Site Restoration | Pending | Well Site Restoration Report (8000-PM-OOGM0075) submitted with missing information. |
| 2363002 | Primary Facility | 2015-04-20 | Routine/Complete Inspection | No Violations Noted | |
| 2434497 | Primary Facility | 2015-12-14 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 11:50 a.m., the cellar was full of gravel, the vent pipe was open and set up with a Taylor plug, there was no gas detected at the perimeter of the cellar, there was 358psi on the production casing and 287psi on the production line. I took a walk around the location and everything looked OK. |
| 2508878 | Primary Facility | 2016-05-24 | Routine/Complete Inspection | No Violations Noted | Inspection of the Hollenbeck well pad in conjunction with the Snake Creek Gathering Pipeline notice of termination inspection. There were no issues observed on the well pad at the time of the inspection. |
| 2528988 | Primary Facility | 2016-10-18 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 13:35p.m., the cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The vent pipe was open and set up with a Taylor plug to check for pressure, the valve on the vent line going to the tank was closed. There was 285psi on the production casing and 277psi on the production line. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 14:15p.m. |
| 2619622 | Primary Facility | 2017-07-25 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 14:55p.m.
The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge, the valve going to the production tank was closed. There was 410psi on the production casing and 210psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 15:35p.m. |
| 2726965 | Primary Facility | 2018-04-27 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
| 2825824 | Primary Facility | 2019-01-11 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was shut in at the GPU by a pneumatic valve. The cellar was full of gravel and I was unable to check for gas at the perimeter of the cellar do too the gravel being frozen. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
| 2845375 | Primary Facility | 2019-02-27 | Routine/Complete Inspection | No Violations Noted | I performed a site inspection of the Hollenbeck well pad on February 27, 2019. The weather was light snow and temperature in the mid 20s.
The well pad was compact and fenced in along the roadside. There was no activity on site during the inspection. The access driveway and well pad surface was frozen hard. The slopes surrounding the site were all very well covered with last years vegetation in abundance. There were no noted areas of slope failure or slumping. All wells were properly labeled. There were no erosional issues noted. There were no violations noted at the time of inspections. |
| Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
|---|---|---|---|---|---|---|
| 1989187 | 615754 | 07/20/2011 | 2011-07-20 | 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | Administrative | Gas well completions report ultimately reviewed 3/2/12. Integrity evaluation of gas well done during GMI investigation found no viols. GMI closed 4/24/13 via non-impact determ ltr. |
| 1989187 | 615755 | 07/20/2011 | 2011-07-20 | 201TAG - Failure to install, in a permanent manner, the permit number on a completed well | Administrative |
For data sources see[9]