37-115-20526

Well Details

Well ID: 37-115-20526
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Franklin Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 148544
Farm/Lease Name: HOLLENBECK 3H
License Status:
Spud Date:
Permit Date: 2011-03-02
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.917217
Longitude: -75.832708

For data sources see[1][2][3]

Well History

Date Event
2011-03-02 New Permit Application
2011-03-11 Performed Spud Operation
2011-05-25 Drilling Completion
2011-12-18 Perforation
2011-12-18 Performed Stimulation
2012-04-30 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-12-18 2011-12-18 5,751 3,645,532

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 WG-36 Gelling Agent Halliburton Energy Services Gel
Guar gum 9000-30-0 100.00 0.00154000
Water Carrier/Base Fluid Water 100.00 87.04
Sand- Silica Sand Halliburton Energy Services Proppant Quartz 14808-60-7 100.00 12.76
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.01
Hydrochloric Acid Halliburton Energy Services Acid Hydrochloric acid 7647-01-0 30.00 0.13
GBW-30 Breaker Halliburton Energy Services Breaker
Hemicellulase enzyme 9012-54-8 15.00 0.00022000
Carbohydrates 95.00 0.00139000
Cla-Web Halliburton Energy Services Clay Control
Proprietary 60.00 0.02
BE-9M Halliburton Energy Services Biocide
Tri-n-butyl tetradecyl phosphonium chloride 81741-28-8 10.00 0.00096000
Methanol 67-56-1 30.00 0.00289000
SP Breaker Halliburton Energy Services Breaker Sodium persulfate 7775-27-1 100.00 0.00146000
LP-65 Halliburton Energy Services Scale Inhibitor Ammonium chloride 12125-02-9 10.00 0.00374000

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2011-12-18 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 XPR RESOURCES LLC 82,144.54 182 0.00 0 0.00 0
2013 XPR RESOURCES LLC 245,146.51 328 0.00 0 0.00 0
2014 XPR RESOURCES LLC 179,253.57 364 0.00 0 0.00 0
2015 SWN PROD CO LLC 155,431.61 361 0.00 0 0.00 0
2016 SWN PROD CO LLC 175,042.00 365 0.00 0 0.00 0
2017 SWN PROD CO LLC 48,825.00 171 0.00 0 0.00 0
2018 SWN PROD CO LLC 24,490.00 271 0.00 0 0.00 0
2019 SWN PROD CO LLC 9,902.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 XPR RESOURCES LLC Drilling Fluid Waste 174.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2013 XPR RESOURCES LLC Produced Fluid 490.83 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013 XPR RESOURCES LLC Produced Fluid 1,300.57 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2013 XPR RESOURCES LLC Produced Fluid 1,664.90 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 XPR RESOURCES LLC Produced Fluid 954.62 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2013 XPR RESOURCES LLC Produced Fluid 1,024.96 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 XPR RESOURCES LLC Produced Fluid 401.41 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 XPR RESOURCES LLC Produced Fluid 612.90 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC010
2014 XPR RESOURCES LLC Produced Fluid 398.75 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 XPR RESOURCES LLC Produced Fluid 2,195.30 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 XPR RESOURCES LLC Produced Fluid 612.95 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 XPR RESOURCES LLC Produced Fluid 981.14 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SOUTHWESTERN ENERGY PROD CO Produced Fluid 3,163.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 1,050.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 SWN PROD CO LLC Produced Fluid 1,531.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 13.75 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 550.25 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 137.50 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes 40.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 1,128.25 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 50.36 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 716.50 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 415.75 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Other Oil & Gas Wastes 194.40 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 57.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Produced Fluid 793.25 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Other Oil & Gas Wastes 5.44 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 30.00 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Produced Fluid 451.50 Bbl SURFACE IMPOUNDMENT 826342

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1974888 Primary Facility 2011-05-11 Drilling/Alteration No Violations Noted Depth of drilling = 431'. Surface casing (13 3/8") set at 431'. Set with 383 sks of 15.2 lb cement with 1.36 Y. Reported 40 bbls return. 20" conductor set at 140'. Bumped plug at 21:15 on 5/10/11. Walked site with Rig mgr. David Phillips. Discussed fixing and maintaining secondary containment. Commented on flare stack height. Height was approximately 8' high which appeared to be low and potentially unsafe. Looked at area of previous spill near sand trap under shakers. Appears spill has been adequately cleaned at this time and this violation has been corrected. Fill slope also stabilized. Inspected cellar for bubbling - none observed.
1987226 Primary Facility 2011-07-07 Follow-up Inspection Pending Drilling complete. Inspected cellar. Fluid above 9 5/8" & conductor. Observed steady stream of bubbling along inside wall of conductor on eastern side. Cannot see source of bubbling due to level of fluid. Further investigation required. Gas well completions report ultimately reviewed 3/2/12. Integrity evaluation of gas well done during GMI investigation found no viols. GMI closed 4/24/13 via non-impact determ ltr.
1987346 Primary Facility 2011-07-07 Routine/Complete Inspection No Violations Noted
1989187 Primary Facility 2011-07-20 Follow-up Inspection Violation(s) Noted Follow up on evidence of bubbling around well head. Observed bubbling in between 9 5/8" and 13 3/8" casing. Minor bubbling outside of 13 3/8" casing. Tagged TOC in 9 5/8 annulus at @ 3' below top of casing. TOP cement tagged at @ 12' below casing on 13 3/8" annulus. Violations for defective cement and no well tag cited. Gas well completions report ultimately reviewed 3/2/12. Integrity evaluation of gas well done during GMI investigation found no viols. GMI closed 4/24/13 via non-impact determ ltr.
2005445 Primary Facility 2011-09-15 Routine/Complete Inspection No Violations Noted
2006739 Primary Facility 2011-09-22 Routine/Complete Inspection No Violations Noted
2007688 Primary Facility 2011-09-23 Follow-up Inspection No Violations Noted
2053521 Primary Facility 2012-03-20 Routine/Complete Inspection Pending Inspected current status and condition of well. Well has been completed and fracced. Well is not online. Observed minor bubbling on 9 x 13 3/8" annulus at the surface. No other bubbling oberved at the time of this inspection. A Mercer service rig is on site and a small crew of workers. DEP will follow up with Operator on condition of well. Gas well completions report ultimately reviewed 3/2/12. Integrity evaluation of gas well done during GMI investigation found no viols. GMI closed 4/24/13 via non-impact determ ltr.
2066945 Primary Facility 2012-05-10 Drilling/Alteration No Violations Noted At time of inspection- Service Rig set up on 1H - preparing wells for production. Inspected cellar - intermittent bubbling observed on outside of 9 5/8" casing. (minor bubbling about every second). Well is shut in - not online yet. Pipleine crews working nearby at time of inspection.
2278322 Primary Facility 2014-06-12 Site Restoration Pending Well Site Restoration Report (8000-PM-OOGM0075) submitted with missing information.
2363002 Primary Facility 2015-04-20 Routine/Complete Inspection No Violations Noted
2434497 Primary Facility 2015-12-14 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:50 a.m., the cellar was full of gravel, the vent pipe was open and set up with a Taylor plug, there was no gas detected at the perimeter of the cellar, there was 358psi on the production casing and 287psi on the production line. I took a walk around the location and everything looked OK.
2508878 Primary Facility 2016-05-24 Routine/Complete Inspection No Violations Noted Inspection of the Hollenbeck well pad in conjunction with the Snake Creek Gathering Pipeline notice of termination inspection. There were no issues observed on the well pad at the time of the inspection.
2528988 Primary Facility 2016-10-18 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:35p.m., the cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The vent pipe was open and set up with a Taylor plug to check for pressure, the valve on the vent line going to the tank was closed. There was 285psi on the production casing and 277psi on the production line. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 14:15p.m.

2619622 Primary Facility 2017-07-25 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 14:55p.m.

The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge, the valve going to the production tank was closed. There was 410psi on the production casing and 210psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 15:35p.m.

2726965 Primary Facility 2018-04-27 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2825824 Primary Facility 2019-01-11 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was shut in at the GPU by a pneumatic valve. The cellar was full of gravel and I was unable to check for gas at the perimeter of the cellar do too the gravel being frozen. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2845375 Primary Facility 2019-02-27 Routine/Complete Inspection No Violations Noted I performed a site inspection of the Hollenbeck well pad on February 27, 2019. The weather was light snow and temperature in the mid 20s.

The well pad was compact and fenced in along the roadside. There was no activity on site during the inspection. The access driveway and well pad surface was frozen hard.

The slopes surrounding the site were all very well covered with last years vegetation in abundance. There were no noted areas of slope failure or slumping.

All wells were properly labeled.

There were no erosional issues noted.

There were no violations noted at the time of inspections.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1989187 615754 07/20/2011 2011-07-20 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days Administrative Gas well completions report ultimately reviewed 3/2/12. Integrity evaluation of gas well done during GMI investigation found no viols. GMI closed 4/24/13 via non-impact determ ltr.
1989187 615755 07/20/2011 2011-07-20 201TAG - Failure to install, in a permanent manner, the permit number on a completed well Administrative

For data sources see[9]

References