37-115-20348

Well Details

Well ID: 37-115-20348
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Dimock Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 149136
Farm/Lease Name: R WARRINER 8
License Status:
Spud Date:
Permit Date: 2010-07-23
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.758753
Longitude: -75.964172

For data sources see[1][2][3]

Well History

Date Event
2010-07-23 New Permit Application
2011-07-20 Permit Renewal Application
2012-03-03 Performed Spud Operation
2012-04-05 New Permit Application
2012-05-01 Drilling Completion
2012-05-22 Perforation
2012-05-22 Performed Stimulation
2012-12-07 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-06-02 2012-06-02 6,602 4,975,362

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 PA Specific 100 mesh Sand Superior Well Services Sand - Bulk - Pennsylvania Quartz 14808-60-7 99.90 0.59
Alumina 1344-28-1 1.10 0.00651800
Titanium dioxide 13463-67-7 0.10 0.00059300
Ferric oxide 1309-37-1 0.10 0.00059300
WFR-3B Superior Well Services Friction Reducer 1,2-Propylene glycol 57-55-6 15.00 0.01
Ethoxylated C12-16 alcohols 68551-12-2 15.00 0.01
Distillates, petroleum, hydrotreated light 64742-47-8 50.00 0.05
Microparticle 1.00 0.00103000
Poly(oxy-1,2-ethanediyl), .alpha.,.alpha.'-[[(9Z)-9-octadecenylimino]di-2,1-ethanediyl]bis[.omega.-hydroxy
-
26635-93-8 5.00 0.00514900
Water 7732-18-5 40.00 0.04
1,2-Propylene glycol 57-55-6 40.00 0.04
Iron Acid 10M (12.6-18.0) Superior Well Services Acid Blend Hydrochloric acid 7647-01-0 15.80 0.20
Proprietary 1.20 0.01
Water 7732-18-5 84.10 1.06
PA Specific 40/70 mesh Sand Superior Well Services Sand - Bulk - Pennsylvania Titanium dioxide 13463-67-7 0.10 0.01
Quartz 14808-60-7 99.90 10.46
Alumina 1344-28-1 1.10 0.11
Ferric oxide 1309-37-1 0.10 0.01
Water Carrier/Base Fluid 100.00 87.27
KR-153SL Superior Well Services Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00547900
Water 7732-18-5 80.00 0.02
Super TSC LT Superior Well Services Paraffin & Scale Additive Proprietary 50.00 0.01
Water 7732-18-5 60.00 0.01
Proprietary 15.00 0.00367700
0.00367700
Proprietary 15.00
Acid Inhibitor 2 (AI-2) Superior Well Services Acid Corrosion Inhibitor Poly(oxy-1,2-ethanediyl), alpha-(nonylphenyl)-omega-hydroxy-

,
branched

68412-54-4 13.00 0.00013800
Water 7732-18-5 40.00 0.00042500
Isopropanol 67-63-0 15.00 0.00016000
Propargyl alcohol 107-19-7 20.00 0.00021300
Glycol Ethers 20.00 0.00021300
Tar bases, quinoline derivatives,
benzyl chloride-quaternized
72480-70-7 10.00 0.00010600

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-05-22 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2011 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 1,172,999.46 197 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 1,116,357.27 365 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 884,529.84 361 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 375,243.79 353 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 571,122.51 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 417,491.34 363 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 278,149.00 363 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 302,317.00 364 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CABOT OIL & GAS CORP Drill Cuttings 874.14 Tons LANDFILL NY STATE #32S11
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 19.62 Tons LANDFILL 101534
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 4.00 Tons LANDFILL 101571
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 0.33 Bbl LANDFILL 100081
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 448.82 Bbl LANDFILL NY STATE #32S11
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 2,493.93 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Basic Sediment 12.21 Bbl LANDFILL THR029
2012 CABOT OIL & GAS CORP Fracing Fluid Waste 7,170.25 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 16.21 Tons LANDFILL 100945
2012 CABOT OIL & GAS CORP Basic Sediment 5.57 Bbl LANDFILL 100081
2012 CABOT OIL & GAS CORP Produced Fluid 3,165.46 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Basic Sediment 14.09 Bbl LANDFILL 101534
2012 CABOT OIL & GAS CORP Produced Fluid 14.84 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2012 CABOT OIL & GAS CORP Drill Cuttings 468.71 Tons LANDFILL THR029
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 25.67 Bbl LANDFILL 101534
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 244.66 Bbl LANDFILL THR029
2013 CABOT OIL & GAS CORP Produced Fluid 368.11 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 304.10 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 10.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Produced Fluid 620.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 139.88 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 4.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 130.63 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 213.22 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 22.45 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Soil Contaminated by Oil 4.50 Tons LANDFILL THR029
2017 CABOT OIL & GAS CORP Produced Fluid 80.92 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Soil Contaminated by Oil & Gas Related Spills 4.50 Tons LANDFILL THR029
2017 CABOT OIL & GAS CORP Waste Water Treatment Sludge 0.83 Tons LANDFILL 301358
2018 CABOT OIL & GAS CORP Produced Fluid 125.02 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 44.15 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 176.02 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2045795 Primary Facility 2012-02-14 Routine/Complete Inspection No Violations Noted
2058794 Primary Facility 2012-04-10 Follow-up Inspection No Violations Noted While drilling out 9 5/8" discovered were wearing on casing from 650' to 1638'. Currently waiting on 7" casing to be delivered. Will be setting 7" at 5090' and cementing to @ 1700' (just below 9 5/8" shoe"). Will run 7" later tonight and cement. Then will drill out to TD and run 4 1/2" prod. string with non- rotating pipe rubbers 91 every third jt.). main reason running 7" is to provide an addition well control string and to protect 9 5/8".
2060163 Primary Facility 2012-04-17 Drilling/Alteration No Violations Noted Patterson 252. Co. Man provided cement reports for 13 3/8", 9 5/8" and 7" casing strings. drilling ahead at 6537' on SOBM. All cement reports indicate adequate returns to surface with no fall back reported. Drilers log on site and up to date. No groundwater reported and no shallow gas shows detected above background levels. Secondary containment in place and in good condition. Last well on pad at this time. Rig will move to next location upon completion of this well.
2152216 Primary Facility 2013-03-29 Routine/Partial Inspection No Violations Noted
2389952 Primary Facility 2015-07-14 Routine/Complete Inspection No Violations Noted
2487303 Primary Facility 2016-05-24 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:00 a.m., the cellar was full of water and overflowing onto the pad with no bubbling noticed, the (13x9) vent pipe was open and venting to a tank, the (9x7) vent pipe was open and venting to a tank, there was 572psi on the production casing. I took a walk around the location and everything looked OK.

I contacted Steve Watson of Cabot Oil & Gas to let him know about the cellar and suggest it be vacced out. I left the site at 11:35 a.m.

2490581 Primary Facility 2016-05-31 Site Restoration No Violations Noted Inspection of the Warriner R P4 Well Pad in response to a submitted Notice of Termination request for the Erosion and Sedimentation Control Permit.

The site has been stabilized and vegetation was found to be greater than 70% uniform perennial growth. Temporary E&S BMPs have been removed from the site. No E&S problems were observed at the time of the inspection. The restored pad size is consistent with the PCSM/Site Restoration Plan. Post construction storm water management devices were in place according to approved plans and appear to be functioning properly.

Based on the site inspection, I recommend this notice of termination be APPROVED.

2544179 Primary Facility 2016-12-09 Incident- Response to Accident or Event No Violations Noted Steve Watson, Environmental Health and Safety Specialist of Cabot Oil and Gas contacted me on 12/8/16 at 4:17 PM to report a spill of production fluid that occurred on 12/8/16 at 3:30 PM. He stated the following during our phone conversation. "A well tender was performing routine maintenance on the well. He was adding soap sticks into the well to flow the wells back. He opened a valve on the well to dump production fluid into a production fluid tank. The fluid went into the tank and overflowed out of a hatch on the top of the tank onto the pad surface. The tank is a double walled tank with no containment around it on the pad surface. The spill volume is unknown at this point, but more than (5) gallons of the fluid were spilled to the pad surface, so the spill is considered a reportable volume. There is a (30) foot area of staining on the pad surface near the tank. We will cover the spill area until Resource Environmental gets here at 8AM tomorrow, 12/9/16, to delineate the extent of the contaminatio
2545543 Primary Facility 2016-12-19 Administrative/File Review No Violations Noted This administrative inspection has been created to document a production fill spill in the range of (10-20) gallons to the pad surface that occurred on 12-8-16 as documented in the Department's 12-9-16 inspection report. Cabot submitted a Remediation Summary Report prepared by Resource Environmental of Montrose, PA to the Department on 12-15-16. The report contains a site map of the release area and perimeter of excavation, (5) test pit locations dug for soil conductivity screening, conductivity readings measured after the final excavation and a remediation summary report containing a description of the incident, remedial action and waste disposal information. The description of the incident in the report states that the following. The spill of (10-20) gallons occurred on 12-8-16. An unanticipated surge of production fluid flowed through the dump line to the production fluid tanks when a well tender was performing maintenance. The spill impacted the immediate area of the production fluid tanks. The re
2660797 Primary Facility 2017-11-15 Routine/Complete Inspection No Violations Noted Arrived on location at: 13:30. Weather: Clear, mild ~ 44 degs. (2) wells have been drilled on this pad, the Warriner, R. 4H and 8H. Both wells were in production at time of inspection. Both wells (13x9) and (9x5) annuli were open and venting, plumbed to a common vent tank. The (5/P) annular vent was shut in to SCADA pressure monitor sending signal to readout mounted by GPU. A Gas check performed at the common annular vent tank showed 5% LEL, 0% CH4. -All wells Prod. casing, Static and Differential pressures were being monitored by wireless sending units to onsite Total Flow Control Unit "TFCU". (See individual well insp. reports for pressures.) - TFCU readings were taken off LED readouts mounted by GPUs at ~ 14:00. (SP= static press., CP= prod. casing press., DP= differential press.) - 8H: SP= 444 psi, CP= 430 psi., DP= 266 psi. - Overall, wells and pad were found in good condition. No obvious concerns noted at time of inspection. No violations noted. Left location at 14:30.

For data sources see[9]