37-115-20275

Well Details

Well ID: 37-115-20275
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Dimock Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 149136
Farm/Lease Name: R WARRINER 4
License Status:
Spud Date:
Permit Date: 2010-03-22
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.758850
Longitude: -75.964072

For data sources see[1][2][3]

Well History

Date Event
2010-03-22 New Permit Application
2011-03-21 Permit Renewal Application
2012-03-01 Performed Spud Operation
2012-03-31 Drilling Completion
2012-05-19 Perforation
2012-05-19 Performed Stimulation
2012-12-07 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-06-02 2012-06-02 6,614 3,839,724

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Super TSC LT Superior Well Services Paraffin & Scale Additive Proprietary 15.00 0.00362300
Water 7732-18-5 60.00 0.01
Proprietary 50.00 0.01
Acid Inhibitor 2 (AI-2) Superior Well Services Acid Corrosion Inhibitor Water 7732-18-5 40.00 0.00040700
Isopropanol 67-63-0 15.00 0.00015300
Poly(oxy-1,2-ethanediyl), alpha-(nonylphenyl)-omega-hydroxy-

,
branched

68412-54-4 13.00 0.00013200
Tar bases, quinoline derivatives,
benzyl chloride-quaternized
72480-70-7 10.00 0.00010200
Glycol Ethers 20.00 0.00020400
Propargyl alcohol 107-19-7 20.00 0.00020400
WFR-3B Superior Well Services Friction Reducer 0.02
Ethoxylated C12-16 alcohols 68551-12-2 15.00 0.01
1,2-Propylene glycol 57-55-6 40.00
Poly(oxy-1,2-ethanediyl), .alpha.,.alpha.'-[[(9Z)-9-octadecenylimino]di-2,1-ethanediyl]bis[.omega.-hydroxy
-
26635-93-8 5.00 0.00360100
Microparticle 1.00 0.00072000
1,2-Propylene glycol 57-55-6 15.00 0.01
Distillates, petroleum, hydrotreated light 64742-47-8 50.00 0.03
Water 7732-18-5 40.00 0.02
XL-8 Superior Well Services Crosslinker Boric acid 10043-35-3 7.00 0.00038000
Proprietary
Ethylene glycol 107-21-1 30.00 0.00162700
PA Specific 100 mesh Sand Superior Well Services Sand - Bulk - Pennsylvania Titanium dioxide 13463-67-7 0.10 0.00064000
Ferric oxide 1309-37-1 0.10 0.00064000
Alumina 1344-28-1 1.10 0.00703600
Quartz 14808-60-7 99.90 0.63
Water Carrier/Base Fluid 100.00 87.90
Iron Acid 10M (12.6-18.0) Superior Well Services Acid Blend Water 7732-18-5 84.10 0.50
Hydrochloric acid 7647-01-0 15.80 0.09
Proprietary 1.20 0.00726900
PA Specific 40/70 mesh Sand Superior Well Services Sand - Bulk - Pennsylvania Ferric oxide 1309-37-1 0.10 0.01
Alumina 1344-28-1 1.10 0.11
Titanium dioxide 13463-67-7 0.10 0.01
Quartz 14808-60-7 99.90 10.48
KR-153SL Superior Well Services Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00548000
Water 7732-18-5 80.00 0.02
LSG-100L Superior Well Services Gelling Agents Ethoxylated propoxylated C12-14 alcohols 68439-51-0 2.00 0.00045700
Distillates, petroleum, hydrotreated light 64742-47-8 60.00 0.01
Quartz 14808-60-7 2.00 0.00045700
Guar gum 9000-30-0 50.00 0.01
OB-2 Superior Well Services Gel Breakers Peroxydisulfuric acid, diammonium salt 7727-54-0 100.00 0.00158100
Silica, amorphous 7631-86-9 10.00 0.00015800

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-05-19 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2011 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 1,399,662.55 197 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 1,367,009.73 365 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 1,039,531.17 357 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 538,298.20 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 663,503.49 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 507,383.65 363 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 376,011.00 364 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 370,718.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CABOT OIL & GAS CORP Drill Cuttings 679.64 Tons LANDFILL NY STATE #32S11
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 13.98 Tons LANDFILL 101534
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 6.00 Tons LANDFILL 101571
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 1.26 Bbl LANDFILL 100081
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 1,187.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Basic Sediment 11.78 Bbl LANDFILL THR029
2012 CABOT OIL & GAS CORP Fracing Fluid Waste 5,099.60 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Basic Sediment 3.26 Bbl LANDFILL 100081
2012 CABOT OIL & GAS CORP Drill Cuttings 89.35 Tons LANDFILL 101247
2012 CABOT OIL & GAS CORP Produced Fluid 2,533.14 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Basic Sediment 10.16 Bbl LANDFILL 101534
2012 CABOT OIL & GAS CORP Produced Fluid 14.84 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2012 CABOT OIL & GAS CORP Drill Cuttings 113.99 Tons LANDFILL THR029
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 13.33 Bbl LANDFILL 101534
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 957.59 Bbl LANDFILL THR029
2013 CABOT OIL & GAS CORP Produced Fluid 358.68 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 414.76 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 10.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Produced Fluid 624.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 154.12 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 4.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 140.37 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 204.28 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 27.55 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Soil Contaminated by Oil 4.50 Tons LANDFILL THR029
2017 CABOT OIL & GAS CORP Produced Fluid 66.08 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Soil Contaminated by Oil & Gas Related Spills 4.50 Tons LANDFILL THR029
2017 CABOT OIL & GAS CORP Waste Water Treatment Sludge 0.76 Tons LANDFILL 301358
2018 CABOT OIL & GAS CORP Produced Fluid 208.98 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 53.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 171.98 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2045790 Primary Facility 2012-02-14 Routine/Complete Inspection No Violations Noted
2053626 Primary Facility 2012-03-21 Drilling/Alteration No Violations Noted Patterson 252. Driling on fluid. Testing BOP's. 250 low 5000 high. Annular 250 hi, 3500 low. (5 mins). Casing test - 30 mins @ 1000 psi. 13 3/8" casing test @ 200 psi/15 mins. Drillers log on site and up to date. Walked site. Secondary containment in place - plastic and mats on entire location. Observed leak on hammer union under gas buster. Crews fixed immediately and cleaned up fluid on containment. No violations observed.
2152215 Primary Facility 2013-03-29 Routine/Partial Inspection No Violations Noted
2389954 Primary Facility 2015-07-14 Routine/Complete Inspection No Violations Noted
2487302 Primary Facility 2016-04-24 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:00 a.m., the cellar was full of water and overflowing onto the pad with no bubbling noticed, the (13x9) vent pipe was open and venting to a tank, the (9x5) vent pipe was open and venting to a tank, there was 581psi on the production casing. I took a walk around the location and everything looked OK.

I contacted Steve Watson of Cabot Oil & Gas to let him know about the cellar and suggest it be vacced out. I left the site at 11:35 a.m.

2490579 Primary Facility 2016-05-31 Site Restoration No Violations Noted Inspection of the Warriner R P4 Well Pad in response to a submitted Notice of Termination request for the Erosion and Sedimentation Control Permit.

The site has been stabilized and vegetation was found to be greater than 70% uniform perennial growth. Temporary E&S BMPs have been removed from the site. No E&S problems were observed at the time of the inspection. The restored pad size is consistent with the PCSM/Site Restoration Plan. Post construction storm water management devices were in place according to approved plans and appear to be functioning properly.

Based on the site inspection, I recommend this notice of termination be APPROVED.

2544177 Primary Facility 2016-12-09 Incident- Response to Accident or Event Pending Steve Watson, Environmental Health and Safety Specialist of Cabot Oil and Gas contacted me on 12/8/16 at 4:17 PM to report a spill of production fluid that occurred on 12/8/16 at 3:30 PM. He stated the following during our phone conversation. "A well tender was performing routine maintenance on the well. He was adding soap sticks into the well to flow the wells back. He opened a valve on the well to dump production fluid into a production fluid tank. The fluid went into the tank and overflowed out of a hatch on the top of the tank onto the pad surface. The tank is a double walled tank with no containment around it on the pad surface. The spill volume is unknown at this point, but more than (5) gallons of the fluid were spilled to the pad surface, so the spill is considered a reportable volume. There is a (30) foot area of staining on the pad surface near the tank. We will cover the spill area until Resource Environmental gets here at 8AM tomorrow, 12/9/16, to delineate the extent of the contaminatio
2545541 Primary Facility 2016-12-19 Administrative/File Review Viol(s) Noted & Immediately Corrected This administrative inspection has been created to document a production fill spill in the range of (10-20) gallons to the pad surface that occurred on 12-8-16 as documented in the Department's 12-9-16 inspection report. Cabot submitted a Remediation Summary Report prepared by Resource Environmental of Montrose, PA to the Department on 12-15-16. The report contains a site map of the release area and perimeter of excavation, (5) test pit locations dug for soil conductivity screening, conductivity readings measured after the final excavation and a remediation summary report containing a description of the incident, remedial action and waste disposal information. The description of the incident in the report states that the following. The spill of (10-20) gallons occurred on 12-8-16. An unanticipated surge of production fluid flowed through the dump line to the production fluid tanks when a well tender was performing maintenance. The spill impacted the immediate area of the production fluid tanks. The re
2660799 Primary Facility 2017-11-15 Routine/Complete Inspection No Violations Noted Arrived on location at: 13:30. Weather: Clear, mild ~ 44 degs. (2) wells have been drilled on this pad, the Warriner, R. 4H and 8H. Both wells were in production at time of inspection. Both wells (13x9) and (9x5) annuli were open and venting, plumbed to a common vent tank. The (5/P) annular vent was shut in to SCADA pressure monitor sending signal to readout mounted by GPU. A Gas check performed at the common annular vent tank showed 5% LEL, 0% CH4. -All wells Prod. casing, Static and Differential pressures were being monitored by wireless sending units to onsite Total Flow Control Unit "TFCU". (See individual well insp. reports for pressures.) - TFCU readings were taken off LED readouts mounted by GPUs at ~ 14:00. (SP= static press., CP= prod. casing press., DP= differential press.) - 4H: SP= 447 psi, CP= 432 psi., DP= 365 psi. - Overall, wells and pad were found in good condition. No obvious concerns noted at time of inspection. No violations noted. Left location at 14:30.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2545541 774696 2016-12-19 2016-12-19 CSL 402(b) Environmental Health & Safety
2545541 774697 2016-12-19 2016-12-19 78.57(a) Environmental Health & Safety
2545541 774698 2016-12-19 2016-12-19 SWMA 301 Environmental Health & Safety

For data sources see[9]

References