If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20275 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.75885,"lon":-75.964072,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Dimock Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 149136 | |
Farm/Lease Name: R WARRINER 4 | |
License Status: | |
Spud Date: | |
Permit Date: 2010-03-22 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.758850 | |
Longitude: -75.964072 |
Date | Event |
---|---|
2010-03-22 | New Permit Application |
2011-03-21 | Permit Renewal Application |
2012-03-01 | Performed Spud Operation |
2012-03-31 | Drilling Completion |
2012-05-19 | Perforation |
2012-05-19 | Performed Stimulation |
2012-12-07 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-06-02 | 2012-06-02 | 6,614 | 3,839,724 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Super TSC LT | Superior Well Services | Paraffin & Scale Additive | Proprietary | 15.00 | 0.00362300 | ||
Water | 7732-18-5 | 60.00 | 0.01 | |||||
Proprietary | 50.00 | 0.01 | ||||||
Acid Inhibitor 2 (AI-2) | Superior Well Services | Acid Corrosion Inhibitor | Water | 7732-18-5 | 40.00 | 0.00040700 | ||
Isopropanol | 67-63-0 | 15.00 | 0.00015300 | |||||
Poly(oxy-1,2-ethanediyl), alpha-(nonylphenyl)-omega-hydroxy-
, |
68412-54-4 | 13.00 | 0.00013200 | |||||
Tar bases, quinoline derivatives, benzyl chloride-quaternized |
72480-70-7 | 10.00 | 0.00010200 | |||||
Glycol Ethers | 20.00 | 0.00020400 | ||||||
Propargyl alcohol | 107-19-7 | 20.00 | 0.00020400 | |||||
WFR-3B | Superior Well Services | Friction Reducer | 0.02 | |||||
Ethoxylated C12-16 alcohols | 68551-12-2 | 15.00 | 0.01 | |||||
1,2-Propylene glycol | 57-55-6 | 40.00 | ||||||
Poly(oxy-1,2-ethanediyl), .alpha.,.alpha.'-[[(9Z)-9-octadecenylimino]di-2,1-ethanediyl]bis[.omega.-hydroxy - |
26635-93-8 | 5.00 | 0.00360100 | |||||
Microparticle | 1.00 | 0.00072000 | ||||||
1,2-Propylene glycol | 57-55-6 | 15.00 | 0.01 | |||||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 50.00 | 0.03 | |||||
Water | 7732-18-5 | 40.00 | 0.02 | |||||
XL-8 | Superior Well Services | Crosslinker | Boric acid | 10043-35-3 | 7.00 | 0.00038000 | ||
Proprietary | ||||||||
Ethylene glycol | 107-21-1 | 30.00 | 0.00162700 | |||||
PA Specific 100 mesh Sand | Superior Well Services | Sand - Bulk - Pennsylvania | Titanium dioxide | 13463-67-7 | 0.10 | 0.00064000 | ||
Ferric oxide | 1309-37-1 | 0.10 | 0.00064000 | |||||
Alumina | 1344-28-1 | 1.10 | 0.00703600 | |||||
Quartz | 14808-60-7 | 99.90 | 0.63 | |||||
Water | Carrier/Base Fluid | 100.00 | 87.90 | |||||
Iron Acid 10M (12.6-18.0) | Superior Well Services | Acid Blend | Water | 7732-18-5 | 84.10 | 0.50 | ||
Hydrochloric acid | 7647-01-0 | 15.80 | 0.09 | |||||
Proprietary | 1.20 | 0.00726900 | ||||||
PA Specific 40/70 mesh Sand | Superior Well Services | Sand - Bulk - Pennsylvania | Ferric oxide | 1309-37-1 | 0.10 | 0.01 | ||
Alumina | 1344-28-1 | 1.10 | 0.11 | |||||
Titanium dioxide | 13463-67-7 | 0.10 | 0.01 | |||||
Quartz | 14808-60-7 | 99.90 | 10.48 | |||||
KR-153SL | Superior Well Services | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00548000 | ||
Water | 7732-18-5 | 80.00 | 0.02 | |||||
LSG-100L | Superior Well Services | Gelling Agents | Ethoxylated propoxylated C12-14 alcohols | 68439-51-0 | 2.00 | 0.00045700 | ||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 60.00 | 0.01 | |||||
Quartz | 14808-60-7 | 2.00 | 0.00045700 | |||||
Guar gum | 9000-30-0 | 50.00 | 0.01 | |||||
OB-2 | Superior Well Services | Gel Breakers | Peroxydisulfuric acid, diammonium salt | 7727-54-0 | 100.00 | 0.00158100 | ||
Silica, amorphous | 7631-86-9 | 10.00 | 0.00015800 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2012-05-19 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CABOT OIL & GAS CORP | 1,399,662.55 | 197 | 0.00 | 0 | 0.00 | 0 |
2013 | CABOT OIL & GAS CORP | 1,367,009.73 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CABOT OIL & GAS CORP | 1,039,531.17 | 357 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 538,298.20 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 663,503.49 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 507,383.65 | 363 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 376,011.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 370,718.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | CABOT OIL & GAS CORP | Drill Cuttings | 679.64 Tons | LANDFILL | NY STATE #32S11 |
2012 | CABOT OIL & GAS CORP | Fracturing Fluid Waste | 13.98 Tons | LANDFILL | 101534 |
2012 | CABOT OIL & GAS CORP | Fracturing Fluid Waste | 6.00 Tons | LANDFILL | 101571 |
2012 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 1.26 Bbl | LANDFILL | 100081 |
2012 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 1,187.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 11.78 Bbl | LANDFILL | THR029 |
2012 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 5,099.60 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 3.26 Bbl | LANDFILL | 100081 |
2012 | CABOT OIL & GAS CORP | Drill Cuttings | 89.35 Tons | LANDFILL | 101247 |
2012 | CABOT OIL & GAS CORP | Produced Fluid | 2,533.14 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 10.16 Bbl | LANDFILL | 101534 |
2012 | CABOT OIL & GAS CORP | Produced Fluid | 14.84 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE001 |
2012 | CABOT OIL & GAS CORP | Drill Cuttings | 113.99 Tons | LANDFILL | THR029 |
2012 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 13.33 Bbl | LANDFILL | 101534 |
2012 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 957.59 Bbl | LANDFILL | THR029 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 358.68 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 414.76 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 10.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2014 | CABOT OIL & GAS CORP | Produced Fluid | 624.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 154.12 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 4.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 140.37 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 204.28 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 27.55 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Soil Contaminated by Oil | 4.50 Tons | LANDFILL | THR029 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 66.08 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CABOT OIL & GAS CORP | Soil Contaminated by Oil & Gas Related Spills | 4.50 Tons | LANDFILL | THR029 |
2017 | CABOT OIL & GAS CORP | Waste Water Treatment Sludge | 0.76 Tons | LANDFILL | 301358 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 208.98 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 53.85 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 171.98 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2045790 | Primary Facility | 2012-02-14 | Routine/Complete Inspection | No Violations Noted | |
2053626 | Primary Facility | 2012-03-21 | Drilling/Alteration | No Violations Noted | Patterson 252. Driling on fluid. Testing BOP's. 250 low 5000 high. Annular 250 hi, 3500 low. (5 mins). Casing test - 30 mins @ 1000 psi. 13 3/8" casing test @ 200 psi/15 mins. Drillers log on site and up to date. Walked site. Secondary containment in place - plastic and mats on entire location. Observed leak on hammer union under gas buster. Crews fixed immediately and cleaned up fluid on containment. No violations observed. |
2152215 | Primary Facility | 2013-03-29 | Routine/Partial Inspection | No Violations Noted | |
2389954 | Primary Facility | 2015-07-14 | Routine/Complete Inspection | No Violations Noted | |
2487302 | Primary Facility | 2016-04-24 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 11:00 a.m., the cellar was full of water and overflowing onto the pad with no bubbling noticed, the (13x9) vent pipe was open and venting to a tank, the (9x5) vent pipe was open and venting to a tank, there was 581psi on the production casing. I took a walk around the location and everything looked OK.
I contacted Steve Watson of Cabot Oil & Gas to let him know about the cellar and suggest it be vacced out. I left the site at 11:35 a.m. |
2490579 | Primary Facility | 2016-05-31 | Site Restoration | No Violations Noted | Inspection of the Warriner R P4 Well Pad in response to a submitted Notice of Termination request for the Erosion and Sedimentation Control Permit.
The site has been stabilized and vegetation was found to be greater than 70% uniform perennial growth. Temporary E&S BMPs have been removed from the site. No E&S problems were observed at the time of the inspection. The restored pad size is consistent with the PCSM/Site Restoration Plan. Post construction storm water management devices were in place according to approved plans and appear to be functioning properly. Based on the site inspection, I recommend this notice of termination be APPROVED. |
2544177 | Primary Facility | 2016-12-09 | Incident- Response to Accident or Event | Pending | Steve Watson, Environmental Health and Safety Specialist of Cabot Oil and Gas contacted me on 12/8/16 at 4:17 PM to report a spill of production fluid that occurred on 12/8/16 at 3:30 PM. He stated the following during our phone conversation. "A well tender was performing routine maintenance on the well. He was adding soap sticks into the well to flow the wells back. He opened a valve on the well to dump production fluid into a production fluid tank. The fluid went into the tank and overflowed out of a hatch on the top of the tank onto the pad surface. The tank is a double walled tank with no containment around it on the pad surface. The spill volume is unknown at this point, but more than (5) gallons of the fluid were spilled to the pad surface, so the spill is considered a reportable volume. There is a (30) foot area of staining on the pad surface near the tank. We will cover the spill area until Resource Environmental gets here at 8AM tomorrow, 12/9/16, to delineate the extent of the contaminatio |
2545541 | Primary Facility | 2016-12-19 | Administrative/File Review | Viol(s) Noted & Immediately Corrected | This administrative inspection has been created to document a production fill spill in the range of (10-20) gallons to the pad surface that occurred on 12-8-16 as documented in the Department's 12-9-16 inspection report. Cabot submitted a Remediation Summary Report prepared by Resource Environmental of Montrose, PA to the Department on 12-15-16. The report contains a site map of the release area and perimeter of excavation, (5) test pit locations dug for soil conductivity screening, conductivity readings measured after the final excavation and a remediation summary report containing a description of the incident, remedial action and waste disposal information. The description of the incident in the report states that the following. The spill of (10-20) gallons occurred on 12-8-16. An unanticipated surge of production fluid flowed through the dump line to the production fluid tanks when a well tender was performing maintenance. The spill impacted the immediate area of the production fluid tanks. The re |
2660799 | Primary Facility | 2017-11-15 | Routine/Complete Inspection | No Violations Noted | Arrived on location at: 13:30. Weather: Clear, mild ~ 44 degs. (2) wells have been drilled on this pad, the Warriner, R. 4H and 8H. Both wells were in production at time of inspection. Both wells (13x9) and (9x5) annuli were open and venting, plumbed to a common vent tank. The (5/P) annular vent was shut in to SCADA pressure monitor sending signal to readout mounted by GPU. A Gas check performed at the common annular vent tank showed 5% LEL, 0% CH4. -All wells Prod. casing, Static and Differential pressures were being monitored by wireless sending units to onsite Total Flow Control Unit "TFCU". (See individual well insp. reports for pressures.) - TFCU readings were taken off LED readouts mounted by GPUs at ~ 14:00. (SP= static press., CP= prod. casing press., DP= differential press.) - 4H: SP= 447 psi, CP= 432 psi., DP= 365 psi. - Overall, wells and pad were found in good condition. No obvious concerns noted at time of inspection. No violations noted. Left location at 14:30. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2545541 | 774696 | 2016-12-19 | 2016-12-19 | CSL 402(b) | Environmental Health & Safety | |
2545541 | 774697 | 2016-12-19 | 2016-12-19 | 78.57(a) | Environmental Health & Safety | |
2545541 | 774698 | 2016-12-19 | 2016-12-19 | SWMA 301 | Environmental Health & Safety |
For data sources see[9]