If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20187 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.733816,"lon":-75.876477,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Dimock Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: | |
Farm/Lease Name: GESFORD 9 | |
License Status: | |
Spud Date: | |
Permit Date: 2009-07-13 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 41.733816 | |
Longitude: -75.876477 |
Date | Event |
---|---|
2008-09-25 | Performed Spud Operation |
2009-07-13 | New Permit Application |
2009-08-23 | Drilling Completion |
2010-04-22 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | CABOT OIL & GAS CORP | 13904.00 | 105 | 0.00 | 0 | 0.00 | 0 |
2010 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1822383 | Primary Facility | 2009-08-21 | Follow-up Inspection | Violation(s) Noted | Spill of @100 gallons of diesel on pad. Day tank on air pak unit overflowed. Spill ocurred on 8/19/09 at approximately 9:00 am. GDS soaked up fuel with pads and scraped up soil. Resource env'l is overseeing sampling and reporting for GDS. |
1832152 | Primary Facility | 2009-08-27 | Routine/Complete Inspection | Violation(s) Noted | |
1833417 | Primary Facility | 2009-09-25 | Follow-up Inspection | No Violations Noted | An existing road was used to access the well site. The road and drill pad are stoned with limestone. At the time of inspection, there was no activity on site. Gas seepage was observed in the cellar of the well. Bubbling was observed coming to the surface around the 9-5/8 casing. Due to the amount of water in the cellar, it could not be determined a the time of inspection where the gas seepage was coming from. |
1835387 | Primary Facility | 2009-10-14 | Follow-up Inspection | No Violations Noted | At the time of inspection, there was no drilling activity on site. The inspection was completed as a follow up of a previous inspection performed on 9/25/09 where gas seepage was observed in the cellar of the well. During this inspection, bubbling was observed coming to the surface around the 16" conductor. There was several feet of water in the cellar of the well. Due to the amount of water in the cellar, it could not be determined where the gas seepage was coming from. |
1845068 | Primary Facility | 2009-11-10 | Follow-up Inspection | No Violations Noted | During this inspection, bubbling was observed coming to the surface around the 16" conductor. There was several feet of water in the cellar of the well. Due to the amount of water in the cellar, it could not be determined where the gas seepage was coming from. The well is currently on-line. |
1868937 | Primary Facility | 2010-03-08 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | |
1876537 | Primary Facility | 2010-04-13 | Follow-up Inspection | No Violations Noted | I inspected the well head for evidence of leakage. There was standing water present in the cellar. Visible bubbling was observed along the outside of conductor. The 9-5/8" vent was open. The well was shut in and taken offline. A new well head has been placed on the well. Gas readings were collected using a Model 60 gas meter. A reading of 38% Methane was detected when the gas probe was inserted into the 9-5/8" vent pipe riser. No other detections of were observed around the well head. There was no activity on location. The reserve pit is still open containing residual drill cuttings and fluid. There was approximately 6' of freeboard in the pit. |
1879763 | Primary Facility | 2010-04-21 | Drilling/Alteration | No Violations Noted | John Carford-co. man on site. Ran Temp/acoutsic log on gesford 3 and 9. GDS rig 15 on site and over Gesford 9. Crews reclaiming reserve pit. Mr. Crawrod stated plan tomorrow is to set plug on gesford 9 and run CBL. |
1879777 | Primary Facility | 2010-04-22 | Drilling/Alteration | No Violations Noted | Co. Man John Crawford on site. GDS Rig 15 over Gesford 9. Ran CBL this morning on Gesford 9. At time of inspection, Mr. Crawford was waiting on further instructions from Cabot as revisions were being made to plugging of wells. |
1879798 | Primary Facility | 2010-04-26 | Drilling/Alteration | No Violations Noted | Co. man on site John Crawford. I met with Doug Gosnell and MArk Howard. Set plug and pressured up to 1000lbs which held for 30 mins with no leak off. Perforated casing 860-862' with 4shots/ft for total of 8 holes using a 3 3/8" Tag Gun. Pressured up on perforated area to 1000lbs for 30 mins and had no leak off. Cement retainer set at 850'. TOH and shut in well. |
1881308 | Primary Facility | 2010-04-29 | Drilling/Alteration | No Violations Noted | no current activity on well. well is shut in. bubling present in cellar of well.. operator waiting on cement delivery and pumping services to continue plugging well. |
1881352 | Primary Facility | 2010-04-30 | Drilling/Alteration | No Violations Noted | No activity on this well currently. Bubbling still present in cellar. Plugging activities temporarily on hold while waiting for delivery of cement. |
1881360 | Primary Facility | 2010-05-03 | Drilling/Alteration | No Violations Noted | No activities on well according to Doug Gosnell of Cabot. |
1883142 | Primary Facility | 2010-05-05 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | At time of inspection there was no activity on well. Well is shut in. Plugging procedures have begun. Minor bubling was observed in cellar of well outside of conductor pipe. No one from Cabot was on site. |
1883225 | Primary Facility | 2010-05-06 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | At the time of inspection I met with Mark Howard of Boots and Coots on site. The well is shut. Currently there is no activity on this well. There is a 300 lb gauge on the 13 3/8" casing which continues to show 0 pressure. There was apporximately 6" of standing water in the cellar. Intermittent bubbling was observed coming to surface around the outside of the conductor. |
1883297 | Primary Facility | 2010-05-10 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | At the time of inspection I met with Mark Howard of Boots and Coots on site. The well is shut in. Currently there is no activity on this well. There was approximately 1-2" of standing water in the cellar. Minor bubbling was observed coming to surface around the outside of the conductor. The bubbling was continuous. |
1886414 | Primary Facility | 2010-05-24 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | At the time of inspection I met with Mark Howard of Boots and Coots who has been overseeing plugging activities for Cabot. Mr. Howard summarized the recent activities. The 7" and 9 5/8" casings were mechanically cut at 300'. An injection rate could not be established at this depth, and therefore no cement was squeezed into the formation. Cement was spotted at 300', and top of cement was tagged at 200' in the 7" casing. The top of the 7" casing was cut approximately 6' below the top of the 9 5/8" casing. The cut section of 7" casing (@ 11') was pulled. The remaining open sections of casings were then filled to surface with gravel. A metal plate was welded on top of the 9 5/8" casing with a 2" port. A 2" riser with a bull plug and needle valve was screwed into the metal plate. A section of 4 1/2" casing was welded to the well extending approximately 4' above surface. A metal plate containing the well permit number was welded to the top of the 4 1/2" riser. |
1886583 | Primary Facility | 2010-05-18 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Crew trying to pull section of 7" casing cut at 425'. A mechanical cut was made on the 7" and 9 5/8" casings at 425'. Crew could not pull the 7" out of the hole while I was on site. Plan is to TIH with mechanical cutter and re-cut casing. |
1887834 | Primary Facility | 2010-05-27 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | At the time of inspection, there was no activity on site. All drilling equipment has been mobilized off location. The cellar of the well had approximately 2¿ of standing water in the western portion of the hole. Minor ¿constant bubbling was observed in between the 13 3/8¿ conductor and 9 5/8¿ casing. The bubbling appeared on the eastern side of the well head in an area where the 9 5/8¿ butted up against the 13 3/8¿ conductor. A 100 lb pressure gauge installed on the 2¿ riser connected to the 9 5/8¿ casing showed 0 psi at the time of inspection. DEP collected a video of the conditions of the wellhead during this inspection. |
1887835 | Primary Facility | 2010-05-28 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | At the time of inspection I met with Bill Shreve of Cabot. Upon inspection, the bubbling observed the previous day in between the 13 3/8¿ conductor and 9 5/8¿ casing was no longer present. A soapy water mixture was introduced around the well head and casings. There was no bubbling observed in between the casings or outside the conductor during the time of this inspection. DEP collected a video of the conditions of the well head at the time of inspection. |
1890918 | Primary Facility | 2010-06-08 | Routine/Complete Inspection | No Violations Noted | |
1891355 | Primary Facility | 2010-06-11 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Cellar had 3-4' of standing water. GDS on site with pump truck to pump down water. While pumping down, observed minor bubbling coming from in between 9 5/8" and 13 3/8" casings. Crews on site installing protective barrier around well. |
1917659 | Primary Facility | 2010-10-04 | Routine/Complete Inspection | No Violations Noted | Inspected well for evidence of gas seepage around well head. Well has been plugged. Monument with API# in place. Celllar is open and full of water. No evidence of gas observed at time of inspection. No activity on site. |
1959377 | Primary Facility | 2011-03-22 | Routine/Complete Inspection | No Violations Noted | |
2481736 | Primary Facility | 2016-04-26 | Routine/Partial Inspection | No Violations Noted | The Department was on site at the Gesford, K. Pad 3 to conduct a Routine Partial Inspection. The E&S Inspection Log indicated that Mike Brilla (TEC) conducted a PCSM inspection on 3/7/16. At the time of the inspection, the site appeared to meet temporary stabilization requirements. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1822383 | 569899 | 08/21/2009 | 2009-08-21 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | SWMA 6018.301 Management of residual waste
Act ROL granted on 11/24/2009. |
1822383 | 572621 | 08/21/2009 | 2009-08-21 | 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used | Administrative | CSL 402 Potential Pollution
Act ROL granted on 11/24/2009 |
1832152 | 572624 | 08/27/2009 | 2009-08-27 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | SWMA 6018.301 Management of residual waste |
1832152 | 572625 | 08/27/2009 | 2009-08-27 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | CSL 402 Potential Pollution |
For data sources see[6]