If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20171 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.726375,"lon":-75.902975,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Dimock Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 148590 | |
Farm/Lease Name: J GRIMSLEY 2H SE | |
License Status: | |
Spud Date: | |
Permit Date: 2009-05-06 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.726375 | |
Longitude: -75.902975 |
Date | Event |
---|---|
2009-05-06 | New Permit Application |
2009-07-20 | Performed Spud Operation |
2009-09-17 | Drilling Completion |
2009-11-18 | Perforation |
2009-11-18 | Performed Stimulation |
2010-10-01 | DEVIATED |
For data sources see[4]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2009-11-18 | 0 | 0 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | CABOT OIL & GAS CORP | 1,445,442.00 | 260 | 0.00 | 0 | 0.00 | 0 |
2011 | CABOT OIL & GAS CORP | 1,067,492.04 | 360 | 0.00 | 0 | 0.00 | 0 |
2012 | CABOT OIL & GAS CORP | 802,174.07 | 361 | 0.00 | 0 | 0.00 | 0 |
2013 | CABOT OIL & GAS CORP | 566,157.95 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CABOT OIL & GAS CORP | 552,606.13 | 359 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 331,806.17 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 449,861.78 | 359 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 370,263.69 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 278,536.00 | 334 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 293,087.00 | 359 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | CABOT OIL & GAS CORP | Basic Sediment | 2.59 Bbl | LANDFILL | 101534 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 233.50 Tons | LANDFILL | THR029 |
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 218.90 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2010 | CABOT OIL & GAS CORP | Produced Fluid | 439.08 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2010 | CABOT OIL & GAS CORP | Spent Lubricant | 117.30 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 101247 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 107.90 Tons | LANDFILL | NY # 02S17 |
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 131.80 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 1.40 Tons | LANDFILL | 100955 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 22.70 Tons | LANDFILL | 101534 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 107.90 Tons | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 8-4630-00010/00 |
2011 | CABOT OIL & GAS CORP | Basic Sediment | 2.04 Bbl | LANDFILL | 101534 |
2011 | CABOT OIL & GAS CORP | Produced Fluid | 411.71 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 0.28 Tons | LANDFILL | 101534 |
2011 | CABOT OIL & GAS CORP | Basic Sediment | 0.56 Bbl | LANDFILL | 100081 |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 0.63 Bbl | LANDFILL | THR029 |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 0.88 Bbl | LANDFILL | 100081 |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 1.82 Bbl | LANDFILL | 101534 |
2012 | CABOT OIL & GAS CORP | Produced Fluid | 29.68 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE001 |
2012 | CABOT OIL & GAS CORP | Produced Fluid | 323.56 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 61.12 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 101.74 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE002 |
2014 | CABOT OIL & GAS CORP | Produced Fluid | 194.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2014 | CABOT OIL & GAS CORP | Produced Fluid | 155.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 128.22 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 48.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 99.22 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 107.13 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 47.66 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 88.07 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018 | CABOT OIL & GAS CORP | Servicing Fluid | 1.01 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 51.09 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Soil Contaminated by Oil & Gas Related Spills | 0.10 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2018 | CABOT OIL & GAS CORP | Soil Contaminated by Oil | 0.10 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 114.96 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1825890 | Primary Facility | 2009-08-26 | Drilling/Alteration | Violation(s) Noted | : At the time of inspection, I met with the Company Man at the site. Drilling depth at the time of drilling was 3768¿. Drilling was being performed with mud using an 8-3/4¿ bit. All E/S controls appeared to be in place and functioning properly. The pit liner in the reserve pit appeared to be in good condition. Freeboard in the pit was approximately 8¿. |
1844997 | Primary Facility | 2009-10-19 | Follow-up Inspection | No Violations Noted | : Well installation is completed. Cellar of well has water in it. There were no visible signs of gas leaking around the well head. No bubbling observed in cellar. |
1855946 | Primary Facility | 2010-01-08 | Drilling/Alteration | No Violations Noted | I arrived on site at 10:30 am. I met with John Crawford ¿Completions. Mr. Crawford indicated they were in the process of fishing out lost tools in the hole which included a motor, mill, and two sets of jars. Boots and Coots Well Control was on site with snubbing unit and trying to fish out the tools. The lost tools were at 6975¿ in the vertical portion of well. |
1890371 | Primary Facility | 2010-05-24 | Routine/Complete Inspection | No Violations Noted | |
1957016 | Primary Facility | 2011-03-14 | Routine/Complete Inspection | Violation(s) Noted | |
1971621 | Primary Facility | 2011-05-03 | Follow-up Inspection | No Violations Noted | |
2109738 | Primary Facility | 2012-10-19 | Incident- Response to Accident or Event | No Violations Noted | Specifics associated with this inspection report can be referred to in the J Grimsley (1) 10-19-12 inspection report. Permit number is 115-20095. |
2172535 | Primary Facility | 2013-05-29 | Routine/Partial Inspection | No Violations Noted | |
2530993 | Primary Facility | 2016-10-20 | Site Restoration | No Violations Noted | Inspection of the Grimsley J P1 in response to a submitted Notice of Termination request for the Erosion and Sedimentation Control Permit. EPS, Jon Sassi, was also present on this inspection.
The site has been stabilized and vegetation was found to be greater than 70% uniform perennial growth. Temporary E&S BMPs have been removed from the site. No E&S problems were observed at the time of the inspection. Post Construction Stormwater Management BMPs appear to be installed properly according to the site restoration plans. The well pad is less than or equal to the size indicated on the site restoration plans. Based on the site inspection, I recommend this notice of termination be APPROVED. Jon and I also conducted a general inspection of the pad. Signs and labeling appeared to be correct. The mailbox contained the required items. There were no apparent issues with containment. Conductivity readings of water on the pad were of no concern. |
2712759 | Primary Facility | 2018-03-30 | Routine/Complete Inspection | No Violations Noted | There was no activity at the site. There are no violations noted. If you have any questions, please contact me. |
2788902 | Primary Facility | 2018-10-01 | Routine/Complete Inspection | Pending | Arrived on location at 09:00. Weather: ~ 65 degs., Overcast with slight breeze. Onsite to initiate 72 hr. pressure build up test "PBUT" on the annuli of the Grimsley 1V & 2H wells. GDS Vac Truck was onsite to empty well cellars to verify annuli vent connections. Both wells, (9 5/8"x 5 1/2") annuli have been isolated and were venting to onsite poly vent tanks. Both wells (16"x 9 5/8") cemented annuli had open top 16" casings in cellar. No bubbling was noted in well cellars prior to pump out.
- Upon arrival, I was accompanied by DEP Geologist, Eric Rooney and Cabot O&G Reps. Ben Whitaker and Keenan Small. Prior to shutting in wells annuli, initial gas screenings and flow checks were performed at the 1V & 2H annuli using the Depts. Altair 5X gas meter, calibrated this morning, and Cabots' RS-484 Alicat "Whisper" flow meter. Pre-shut in screenings showed: - 1V: (9 5/8"x 5 1/2") = 100% CH4, 100.3 cf/d - 2H: (9 5/8"x 5 1/2") = 100% CH4, 187.0 cf/d - Both wells (9 5/8"x 5 1/2") annuli were shut in to start 72 hr P |
2788908 | Primary Facility | 2018-10-04 | Routine/Complete Inspection | Pending | Arrived on location at 08:45. Onsite to conclude 72 hr PBUT being performed on the Grimsley 1V & 2H wells (9 5/8"x 5 1/2") annuli. I was accompanied by D.E.P. Reps. Eric Rooney, Geologist and Ulyana Trenovich, OGI. Cabot O&G Reps. Ben Whitaker and Keenan Small and Selman and Associate Reps. Kadee Oliver and Tyler Thomas.
Ending pressure readings were checked at ~ 09:00 and are listed below: - Grimsley 1V: (9 5/8"x 5 1/2") = 49.0 psi. Samples collected at ~ 09:10. - Grimsley2H: (9 5/8"x 5 1/2") = 269.4.0 psi. Samples collected at ~ 09:20. Water levels in both well cellars was full at time of inspection. Bubbling was noted in the Grimsley 1V cellar. A GDS vacuum truck was on location to pump out well cellars. The 1V cellar water level was pumped down revealing origin of bubbling at top seam of 9 5/8" casing fitting. (See pic #1 for 1V) Water level was pumped down further showing no further bubbling noted beneath this casing seam. (See pic #2 for 1V). A gas sample was collected over the bubbling area at ~ 09:1 |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1825890 | 570859 | 08/26/2009 | 2009-08-26 | 78.122 - Drillers Log not on site | Administrative | generated drillers log. |
1957016 | 606509 | 03/14/2011 | 2011-03-14 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
1957016 | 606510 | 03/14/2011 | 2011-03-14 | 78.53* - Failure to implement and maintain BMPs in accordance with Chapter 102. | Administrative |
For data sources see[8]