X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-20117

Well Details

Well ID: 37-115-20117
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Dimock Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 149151
Farm/Lease Name: RATZEL 3V
License Status:
Spud Date:
Permit Date: 2009-03-06
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.736538
Longitude: -75.862843

For data sources see[1][2][3]

Well History

Date Event
2009-03-06 New Permit Application
2009-04-08 Drilling Completion
2009-07-19 Perforation
2009-08-15 Performed Stimulation
2009-09-17 NEWLY DRILLED
2009-11-03 Performed Spud Operation

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2009-08-15 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 CABOT OIL & GAS CORP 62274.00 126 0.00 0 0.00 0
2010 CABOT OIL & GAS CORP 94,831.50 338 0.00 0 0.00 0
2011 CABOT OIL & GAS CORP 36,036.00 363 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 32,327.58 353 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 24,140.37 365 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 24,248.18 254 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 26,613.81 300 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 20,109.61 357 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 20,365.43 360 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 20,887.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 12,034.00 207 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 158.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2010 CABOT OIL & GAS CORP Produced Fluid 162.48 Bbl REUSE OTHER THAN ROAD SPREADING
2010 CABOT OIL & GAS CORP Basic Sediment 1.90 Bbl LANDFILL 101534
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 95.10 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010 CABOT OIL & GAS CORP Drill Cuttings 47.80 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 101247
2010 CABOT OIL & GAS CORP Drill Cuttings 13.50 Tons LANDFILL NY # 50S08
2010 CABOT OIL & GAS CORP Drill Cuttings 77.80 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 8-4630-00010/00
2010 CABOT OIL & GAS CORP Drill Cuttings 77.80 Tons LANDFILL NY # 02S17
2010 CABOT OIL & GAS CORP Drill Cuttings 1.00 Tons LANDFILL 100955
2011 CABOT OIL & GAS CORP Basic Sediment 0.59 Bbl LANDFILL 101534
2011 CABOT OIL & GAS CORP Produced Fluid 133.87 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CABOT OIL & GAS CORP Produced Fluid 26.64 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 13.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 54.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 66.21 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 17.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2017 CABOT OIL & GAS CORP Produced Fluid 71.28 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 CABOT OIL & GAS CORP Servicing Fluid 1.02 Tons RESIDUAL WASTE PROCESSING FACILITY 301333
2018 CABOT OIL & GAS CORP Produced Fluid 85.64 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 29.21 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Synthetic Liner Materials 12.79 Tons LANDFILL 101247
2019 CABOT OIL & GAS CORP Produced Fluid 15.15 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Servicing Fluid 24.75 Tons LANDFILL 100933

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1845084 Primary Facility 2009-11-10 Follow-up Inspection No Violations Noted I inspected the well head for evidence of leakage. There was no standing water present in the cellar and no visible bubbling observed. The well is currently on-line.
1890859 Primary Facility 2010-06-08 Routine/Complete Inspection No Violations Noted
1973819 Primary Facility 2011-05-13 Routine/Complete Inspection No Violations Noted
2295294 Primary Facility 2014-07-16 Complaint Inspection No Violations Noted
2295355 Primary Facility 2014-07-21 Follow-up Inspection No Violations Noted
2295368 Primary Facility 2014-07-23 Follow-up Inspection No Violations Noted
2528779 Primary Facility 2016-10-12 Site Restoration No Violations Noted Inspection of the Ratzel P1 Well Pad in response to a submitted Notice of Termination request for the Erosion and Sedimentation Control Permit.

The site has been stabilized and vegetation was found to be greater than 70% uniform perennial growth. Temporary E&S BMPs have been removed from the site. No E&S problems were observed at the time of the inspection. Post Construction Stormwater Management BMPs appear to be installed properly according to the site restoration plans. The well pad is less than or equal to the size indicated on the site restoration plans.

Based on the site inspection, I recommend this notice of termination be APPROVED.

2791954 Primary Facility 2018-10-19 Routine/Complete Inspection No Violations Noted Arrived on location at 09:00. Weather: Clear ~ 35 degs. with slight breeze. Onsite to initiate 72 hr. pressure build up test "PBUT" on the annuli of the Ratzel 1H, 2H & 3V wells. Vac Truck had emptied well cellars to verify annuli vent connections. All wells (9 5/8"x 7") & (7"x 4 1/2") annuli have been isolated and were venting to onsite poly vent tanks. All wells (20"x 13 3/8") & (13 3/8"x 9 5/8") cemented annuli had open top casings in cellar. The 2H & 3V wells open casings tops were beneath the cement floor of cellars. (See individual well insp. pictures for cellar details).

- Upon arrival, I met with Cabot O&G Rep. Jeremy Rapp. Prior to shutting in wells annuli, initial gas screenings and flow checks were performed at the wells annuli using the Depts. Altair 5X gas meter, calibrated yesterday, and Cabots' RS-484 Alicat "Whisper" flow meter. Pre-shut in screenings showed gas and flow detected at the following annuli: - 2H: (7"x 4 1/2") = 100% CH4, 575 cf/d - 3V: (7"x 4 1/2") = 100% CH4, 18.5 cf/d

All wel

2795880 Primary Facility 2018-10-22 Routine/Complete Inspection Pending Arrived on location at: 08:45. Weather: Overcast ~ 38 degs. Onsite to conclude the 72-hr. pressure build up test ¿PBUT¿ being performed on the Ratzel 1H, 2H & 3V wells annuli.

- Upon arrival I met with Cabot O&G Reps. Jeremy Rapp and Selman and Associates Reps. Kaydee Oliver and Tyler Thomas. There was also a GDS Vac Truck and Operator onsite to add or remove water to cellar areas as needed. The ending PBUT pressures were checked by Cabot Rep. using a digital Crystal pressure gauge.Ending pressures are listed below: - 1H: (7"x 4 1/2") = 0.0 psi., No gas detected.; (9 5/8"x 7") = -2.2 psi., No gas detected. Cellar was full of water, no bubbling was noted. - 2H: (7"x 4 1/2") = 170.1 psi., Gas sample taken = 100% CH4; (9 5/8"x 7") = -3.1 psi., No gas detected. Cellar was full of water. No bubbling was noted. - 3V: (7"x 4 1/2") = 61.0 psi.*, Gas sample taken = 100% CH4; (9 5/8"x 7") = 24.2 psi.*, Gas sample taken = 100% CH4. Cellar was full of water, no bubbling noted. All shut-in annuli were opened back up, ven

For data sources see[8]