37-115-20008

Well Details

Well ID: 37-115-20008
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Dimock Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 148440
Farm/Lease Name: GREENWOOD 1
License Status: ACTIVE
Spud Date:
Permit Date: 2007-07-31
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 41.751108
Longitude: -75.868132

For data sources see[1][2][3]

Well History

Date Event
2007-07-31 New Permit Application
2007-09-25 Performed Spud Operation
2007-10-12 Drilling Completion
2007-11-09 Perforation
2007-11-09 Performed Stimulation
2008-02-01 NEWLY DRILLED
2010-10-01 REWORKED

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2007-11-09 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2007 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2008 CABOT OIL & GAS CORP 22203.00 15 0.00 0 0.00 0
2009 CABOT OIL & GAS CORP 157714.00 365 0.00 0 0.00 0
2010 CABOT OIL & GAS CORP 60,734.08 181 0.00 0 0.00 0
2011 CABOT OIL & GAS CORP 50,791.90 365 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 27,777.89 353 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 39,348.46 365 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 38,460.19 276 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 17,222.87 356 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 29,962.86 365 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 23,562.66 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 23,109.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 18,274.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 158.90 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2010 CABOT OIL & GAS CORP Produced Fluid 106.09 Bbl REUSE OTHER THAN ROAD SPREADING
2010 CABOT OIL & GAS CORP Basic Sediment 1.85 Bbl LANDFILL 101534
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 95.60 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010 CABOT OIL & GAS CORP Drill Cuttings 48.10 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 101247
2010 CABOT OIL & GAS CORP Drill Cuttings 13.60 Tons LANDFILL NY # 50S08
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 119.05 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0026034
2010 CABOT OIL & GAS CORP Drill Cuttings 78.30 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 8-4630-00010/00
2010 CABOT OIL & GAS CORP Drill Cuttings 78.30 Tons LANDFILL NY # 02S17
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 3,404.76 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2010 CABOT OIL & GAS CORP Drill Cuttings 1.00 Tons LANDFILL 100955
2011 CABOT OIL & GAS CORP Drilling Fluid Waste 80.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CABOT OIL & GAS CORP Drill Cuttings 0.23 Tons LANDFILL 101534
2011 CABOT OIL & GAS CORP Basic Sediment 0.82 Bbl LANDFILL 101534
2011 CABOT OIL & GAS CORP Produced Fluid 67.94 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CABOT OIL & GAS CORP Drill Cuttings 11.64 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE PAD014286009
2012 CABOT OIL & GAS CORP Servicing Fluid 75.00 Bbl LANDFILL 100945
2012 CABOT OIL & GAS CORP Produced Fluid 97.15 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Basic Sediment 0.41 Bbl LANDFILL THR029
2012 CABOT OIL & GAS CORP Basic Sediment 0.40 Bbl LANDFILL 101534
2012 CABOT OIL & GAS CORP Produced Fluid 14.84 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2012 CABOT OIL & GAS CORP Servicing Fluid 0.52 Bbl LANDFILL 100081
2012 CABOT OIL & GAS CORP Servicing Fluid 309.89 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Servicing Fluid 3.30 Bbl LANDFILL 101534
2013 CABOT OIL & GAS CORP Produced Fluid 146.17 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 20.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 68.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 7.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2015 CABOT OIL & GAS CORP Produced Fluid 60.42 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 4.25 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 10.71 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 28.38 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 6.97 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 15.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 16.53 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 23.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 17.56 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1656333 Primary Facility 2007-09-27 Drilling/Alteration No Violations Noted
1656338 Primary Facility 2007-09-26 Drilling/Alteration No Violations Noted
1656342 Primary Facility 2007-09-25 Drilling/Alteration No Violations Noted
1662428 Primary Facility 2007-10-31 Routine/Complete Inspection No Violations Noted
1665467 Primary Facility 2007-11-01 Drilling/Alteration Violation(s) Noted
1671567 Primary Facility 2007-12-12 Site Restoration No Violations Noted
1689289 Primary Facility 2008-02-28 Routine/Complete Inspection No Violations Noted
1723948 Primary Facility 2008-06-18 Routine/Complete Inspection No Violations Noted
1729817 Primary Facility 2008-08-20 Routine/Complete Inspection No Violations Noted
1733048 Primary Facility 2008-09-03 Site Restoration No Violations Noted
1764280 Primary Facility 2009-01-20 Routine/Complete Inspection No Violations Noted
1764287 Primary Facility 2009-01-21 Routine/Complete Inspection No Violations Noted
1765550 Primary Facility 2009-01-21 Routine/Complete Inspection No Violations Noted
1774908 Primary Facility 2009-02-18 Administrative/File Review Violation(s) Noted
1799972 Primary Facility 2009-05-01 Routine/Complete Inspection No Violations Noted
1833448 Primary Facility 2009-09-25 Follow-up Inspection No Violations Noted An existing road was used to access the well site. The road and drill pad are stoned with limestone. The Site ID sign and E/S Plan were present at the entrance of the access road.
1845085 Primary Facility 2009-11-10 Follow-up Inspection No Violations Noted I inspected the well head for evidence of leakage. There was standing water present around the well. No bubbling was observed.
1956786 Primary Facility 2011-03-05 Routine/Complete Inspection No Violations Noted
1980738 Primary Facility 2011-06-13 Follow-up Inspection Violation(s) Noted On site to collect gas readings and isotopic samples. Observed oil sheen in cellar water. Oil has been dumped into ratholes of other three wells on site. See inspection report for full details.
2005228 Primary Facility 2011-09-19 Follow-up Inspection Pending Operator has digital gauges on both 9x5 and 9 x 7 annuli. Readings at time of inspection: 9x5 had no pressure. 9x7 currently reading 44psi. In the process of 30 day shut in.
2007186 Primary Facility 2011-09-27 Follow-up Inspection Pending Follow up on status of 30 day Pressure Recording. 9 x 7" annulus = 65 lbs. 7 x 4 1/2" = 0 lbs.
2007604 Primary Facility 2011-09-02 Routine/Complete Inspection Violation(s) Noted
2009282 Primary Facility 2011-10-03 Follow-up Inspection Pending Digital pressure gauges on well annuli. Operator currently in process of 30-day shut in pressure monitoring program. Pressure readings at time of inspection : 9" x 7"=78.86 psi, 7 "x 4 1/2" = -23.00 psi (0 psi - negative reading likely due to cold ambient air temps). Monitoring being completed as part of ongoing gas migration investigation.
2028178 Primary Facility 2011-12-08 Routine/Complete Inspection Outstanding Violations - No Viols Req'd Well online. Cellar full of water. no bubbling observed. Pipeline crews working on site. Vents are open - venting to Brine Tanks. inspection performed as part of ongoing gas migration investigation.
2033531 Primary Facility 2011-12-05 Incident- Response to Accident or Event No Violations Noted
2053594 Primary Facility 2012-03-20 Drilling/Alteration No Violations Noted Stone service Rig on site. Jim Reistly is Co. Man. Objective is to squeeze cement into 7 x 8 3/4" annular space # 354 ' KB.
2139932 Primary Facility 2013-02-14 Follow-up Inspection No Violations Noted On site to collect pressure reading and isotopic gas sample from annulus of well. DEP reps on site = Steve Watson, Eric Rooney, and Gene Rickard. DEP met with John Smelko of Cabot. Selman reps on site to assist with collection of gas readings and gas sampling. Cabot shut in annuli on well at @9am. A digital pressure gauge was installed on the 7 5/8" x 4 1/2" annulus. Pressure indicated was 13.3 psi. Gauge was removed, and open flow was screened using Model 60 gas meter. Model 60 reading = >5% combustible gas. DEP and Cabot collected samples for isotopic analysis. The pressure gauge was installed on the 9 5/8" x 7" annulus. Pressure reading was 0 psi. Model 60 reading = >5% combustible gas. DEP and Cabot collected samples for isotopic analysis. After completion of sampling, Cabot re-connected vent lines and locked vents open.
2481911 Primary Facility 2016-04-27 Routine/Partial Inspection No Violations Noted The Department was on site at the Greenwood, R. Pad 1 to conduct a Routine Partial Inspection. The E&S Inspection Log indicated that Mike Brilla (TEC) conducted a Post Rain Event Inspection on 4/27/16. It appears as though the landowner has made a road to the left of the access road gate to circumvent said gate. Also, it seems as if the landowner has been working areas on the well site. There is a large area within the well pad surface that looks like wood chips have been strewn across it and sections of plastic packaging are intermixed.

The perimeter ditch does not appear to meet temporary stabilization requirements. The Department requests that the operator investigate the area and deploy a method of erosion control that is consistent with your plan. The production tanks were stained during the inspection. One of the tanks has more staining than the other. The Department requests that the operator inspect the tanks to find the origin of the staining.

2528903 Primary Facility 2016-10-17 Follow-up Inspection No Violations Noted
2642431 Primary Facility 2017-10-02 Site Restoration No Violations Noted I inspected the site for notice of termination (NOT) on October 2, 2017. The site was surrounded by active agriculture (field corn). The access road leading in was in good shape with no rutting and the site was well vegetated on the cut and fill slopes. The pad surface was solid and stable as well. There were no erosional issues noted.

I recommend APPROVAL of this NOT.

There were no violations observed.

2774797 Primary Facility 2018-09-11 Routine/Complete Inspection No Violations Noted Arrived on location at 09:00. Weather: ~ 65 degs., light rain, slight breeze. Onsite to initiate 72 hr. pressure build up test "PBUT" on the annuli of the Greenwood 1V, 6H, 7H & 8H wells. All wells, back side of production casing annuli have been isolated and were venting to onsite poly vent tanks. The 6H, 7H & 8H wells (16"x 9 5/8") cemented annuli had open top 16" casings in cellar *. The 1V wells (9 5/8"x 7") cemented annulus was beneath water level in cellar, no bubbling was noted at time of inspection.

- Upon arrival I met with Cabot O&G Reps. Jeremy Rapp and Sully Rutledge. Prior to shutting in wells annuli, initial gas screenings and flow checks were performed at the 1V (7"x 4 1/2") and 6H, 7H & 8H (9 5/8"x 5 1/2") annuli using the Depts. Altair 5X gas meter, calibrated this morning, and Cabots' RS-484 Alicat "Whisper" flow meter. Pre-shut in screenings showed: - 1V: (7"x 4 1/2") = 100% CH4, 9.2 cf/d; (9 5/8"x 7") open casing top in cellar, No bubbling noted. - 6H: (9 5/8"x 5 1/2") = 100% CH4, 15.2 cf

2775651 Primary Facility 2018-09-14 Routine/Complete Inspection No Violations Noted Arrived on location at 09:00. Weather: ~ 65 degs., light rain, slight breeze. Onsite to initiate 72 hr. pressure build up test "PBUT" on the annuli of the Greenwood 1V, 6H, 7H & 8H wells. All wells, back side of production casing annuli have been isolated and were venting to onsite poly vent tanks. The 6H, 7H & 8H wells (16"x 9 5/8") cemented annuli had open top 16" casings in cellar *. The 1V wells (9 5/8"x 7") cemented annulus was beneath water level in cellar, no bubbling was noted at time of inspection.

- Upon arrival I met with Cabot O&G Reps. Jeremy Rapp and Sully Rutledge. Prior to shutting in wells annuli, initial gas screenings and flow checks were performed at the 1V (7"x 4 1/2") and 6H, 7H & 8H (9 5/8"x 5 1/2") annuli using the Depts. Altair 5X gas meter, calibrated this morning, and Cabots' RS-484 Alicat "Whisper" flow meter. Pre-shut in screenings showed: - 1V: (7"x 4 1/2") = 100% CH4, 9.2 cf/d; (9 5/8"x 7") open casing top in cellar, No bubbling noted. - 6H: (9 5/8"x 5 1/2") = 100% CH4, 15.2 cf

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1665467 527463 11/01/2007 2007-11-01 102.4NOPLAN - No E&S plan developed, plan not on site Administrative
1774908 558001 02/18/2009 2009-02-18 212WELLRCD - Failure to submit well record within 30 days of completion of drilling Administrative
1980738 613560 06/13/2011 2011-06-13 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative violation of 78.56 (a). failure to contain a pollutional substance in a pit or tank.
1980738 613561 06/13/2011 2011-06-13 402CSL B - Failure to meet requirements of permit, rules and regulations, or order of DEP. Environmental Health & Safety vilation of CSL 402. Potential pollution.
1980738 613562 06/13/2011 2011-06-13 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety Unpermitted discharge of residual waste
2007604 621392 09/02/2011 2011-09-02 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used Administrative 402
2007604 621393 09/02/2011 2011-09-02 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
527463 227675 NOV - Notice of Violation Comply/Closed 2007-12-12
558001 244244 NOV - Notice of Violation Superseded 2010-04-15
558001 252129 COA - Consent Order and Agreement Superseded 2010-04-15 $120,000.00 $120,000.00
613560 272559 NOV - Notice of Violation
613561 272559 NOV - Notice of Violation
613562 272559 NOV - Notice of Violation

For data sources see[8]