X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-113-20338

Well Details

Well ID: 37-113-20338
Loading map...
Country: United States
State: Pennsylvania
County: Sullivan
Municipality: Elkland Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 149302
Farm/Lease Name: SIGNORE NORTH UNIT 5H
License Status:
Spud Date:
Permit Date: 2015-04-06
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.548647
Longitude: -76.649406

For data sources see[1][2][3]

Well History

Date Event
2015-04-06 New Permit Application
2016-01-28 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2016-09-26 2016-10-06 7,290 8,023,810 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 EC6486A Nalco Champion Scale Inhibitor Listed Below
Unislick ST-50 CESI Chemical Friction Reducer Listed Below
Sand Sargent/Unimin Proppant Listed Below
Formaldehyde 50-00-0 1 0.00001000 1
Alcohols, C12-16, ethoxylated 68551-12-2 5 0.00323 2481
Ethanol, 2,2',2"-nitrilotris-,
tris(dihydrogen phosphate) (ester), sodium salt
68171-29-9 30 0.00159 1221
Crystallilne silica 14808-60-7 100 12.5932 9,680,100.0
Ammonium acetate 631-61-8 13 0.00839 6451
Water 7732-18-5 100 87.109 66,958,700.0
Acetophenone 98-86-2 1 0.00001000 1
Glutaraldehyde 111-30-8 5 0.00122 940
Alcohols, C12-14, ethoxylated 68439-50-9 5 0.00323 2481
Thiourea 62-56-6 1 0.00001000 1
Quaternary ammonium compound 68424-85-1 10 0.00245 1880
Water 7732-18-5 40 0.00212 1628
Ethoxylated (C10-16) alcohols 68002-97-1 35 0.00006000 46
Methanol 67-56-1 5 0.00001000 7
Hydrochloric acid 7647-01-0 15 0.03049 23438
Alcohols, (C10-16), ethoxylated 68002-97-1 5 0.00323 2481
Ethanol 64-17-5 5 0.00122 940
Diethylene glycol mono-n-butyl ether 112-34-5 60 0.0001 78
Water 7732-18-5 80 0.01957 15041
Ethylene glycol 107-21-1 30 0.00159 1221
Water 7732-18-5 85 0.17278 132814
Distillate, petroleum, hydrotreated, light 64742-47-8 30 0.01937 14886
Bactron K-139 Nalco Champion Biocide Listed Below
Unihib G GeoSafe Acid Inhibitor Listed Below
Water Chief Oil & Gas Carrier/Base Fluid Listed Below
Hydrochloric Acid (15%) PVS Acidizing Listed Below

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 CHIEF OIL & GAS LLC 948,960.16 76 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 1,975,134.16 299 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 1,140,921.48 357 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 943,453.69 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2016 CHIEF OIL & GAS LLC Drilling Fluid Waste 260.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016 CHIEF OIL & GAS LLC Soil Contaminated by Oil 91.13 Tons LANDFILL 301358
2016 CHIEF OIL & GAS LLC Fracturing Fluid Waste 120.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016 CHIEF OIL & GAS LLC Fracturing Fluid Waste 10,000.31 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHIEF OIL & GAS LLC Soil Contaminated by Oil & Gas Related Spills 91.13 Tons LANDFILL 301358
2016 CHIEF OIL & GAS LLC Produced Fluid 15,085.42 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHIEF OIL & GAS LLC Drill Cuttings 1,658.71 Tons LANDFILL 301358
2017 CHIEF OIL & GAS LLC Produced Fluid 2,309.57 Bbl STORAGE PENDING DISPOSAL OR REUSE
2017 CHIEF OIL & GAS LLC Produced Fluid 2,874.35 Bbl REUSE (AT WELL PAD)
2017 CHIEF OIL & GAS LLC Produced Fluid 350.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 CHIEF OIL & GAS LLC Produced Fluid 2,506.80 Bbl REUSE (AT WELL PAD)
2019 CHIEF OIL & GAS LLC Produced Fluid 2,838.03 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2451642 Primary Facility 2016-02-18 Routine/Complete Inspection No Violations Noted Routine inspection conducted to assess general conditions on site. No Chief representatives were present.

Site vegetated with >70% vegetative cover, and temporary erosion and sediment control BMPs have been removed. No ESCGP was issued for this site as the total area of disturbance is less than 5 acres. No evidence of accelerated erosion or sedimentation was observed.

Drilling is currently underway. Containment was in place under the drill rig and appurtenant equipment. Containment was also being used for pumps and generators that were not within the drilling mat area. No evidence of leaks or spills was observed. At the time of inspection, the pad surface was very muddy. However, all of the mud was contained on the pad.

No voilations were cited during this inspection.

2460843 Primary Facility 2016-03-02 Routine/Complete Inspection No Violations Noted Routine inspection conducted to assess general conditions on site. No Chief representatives were present.

Drilling activity is still underway. Site containment was in place and all equipment, chemicals, and fuels on site were located within the containment. No evidence of spills was observed outside of the containment on the pad surface. Some containments were partially filled with water; the water should be removed to provide maximum containment capacity.

No violations were cited during this inspection.

2462526 Primary Facility 2016-03-07 Drilling/Alteration No Violations Noted Arrived at 13:00. Weather: sunny and warm. Patterson 254 onsite, met with Company Man Paul Rico. Drilling depth was 685’for the Signore North Unit 5H at the time of my inspection. Drilling was stopped following BOP testing. Surface cement job had 14 bbls returned to surface. Drilling the surface hole had damaged the bit.
2467829 Primary Facility 2016-03-21 Drilling/Alteration No Violations Noted Arrived at 12:10. Weather: windy and cold. Patterson 254 onsite, met with Company Man Billy Swanson. At the time of my inspection the well had been TD’ed to 15712. Previously while drilling the lateral at 9692’ MD the rig encountered the Onondaga Formation limestone as evidenced by drill cuttings and rock hardness. This appeared to be due to an up-faulting of the Onondaga. In response, the rig pulled back and sidetracked at 8811’MD. From the sidetrack drilling had gone well according to Swanson. Clean-up of a previous SOBM spill was on-going during my inspection. The spill began with a leaking stripper rubber. Once that was fixed, there was a leak in the mud hose. Fine drops of SOBM were sprayed into the field to the west of the pad. Left location @ 13:00.
2529571 Primary Facility 2016-10-20 Routine/Complete Inspection No Violations Noted Routine inspection to assess site conditions during flowback operations.

Screened electrical conductivity in puddls on the well pad surface. Readings ranged from 242 uS/cm to 879 uS/cm. No evidence of any spills such as staining, sheens, or odors were observed.

An area of erosion has started near the southeast corner of the well pad. This appears to be the low corner of the pad, and it appears the flow has concentrated and eroded pad material down the fill slope. None of the eroded material has left the limit-of-disturbance for the site. Merle Wade of Chief was on site and informed of this finding.

No violations were cited during this inspection.

2534933 Primary Facility 2016-11-02 Routine/Complete Inspection No Violations Noted Arrived @ 11:17. Routine inspection of unconventional gas pad following stimulation and flow back. The site was wet following heavy rain, a worker onsite was vaccing up standing water. Flow back equipment was onsite. The Signore North Unit 4H and Signore North Unit 5H were in production. The 1H was not in production at the time of my inspection. Left location @ 11:30.
2599050 Primary Facility 2017-05-26 Routine/Complete Inspection No Violations Noted Three wells in production phase. Three separators within containment. No leaks from production equipment. Site has very steep fill slopes and requires further stabilization to prevent further erosion.
2791419 Primary Facility 2018-10-18 Administrative/File Review Violation(s) Noted Administrative Inspection created to cite a violation against a well in which Chief entered the wellbore less than eight hours after cementing the casing. This inspection/violation is part of a CACP found under Enforcement Record ID #368514.
2812137 Primary Facility 2018-12-06 Routine/Complete Inspection No Violations Noted Arrived onsite for a routine inspection at 12:57; the weather was ~30°F and windy.

There were 3 properly tagged Marcellus wells staged for production. The well cellars were filled with ice. There were 3 GPUs onsite and in secondary containment. The secondary containment onsite was about 25% filled with ice.

The pad area was reduced in size and the site was greater than 70% vegetative cover. No E&S issues were observed.

No violations noted at the time of inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2791419 831077 2018-10-18 2018-10-18 78a85(c)4 Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
831077 368514 CACP - Consent Assessment of Civil Penalty COMP - Completed 2018-10-18 2018-10-18 $220,000.00 $220,000.00

For data sources see[8]

References