37-105-21922

Well Details

Well ID: 37-105-21922
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: Pike Township
Operator Name: JKLM ENERGY LLC
Well Pad ID: 154634
Farm/Lease Name: JUDSON HOLLOW 302-3HU
License Status:
Spud Date:
Permit Date: 2018-07-13
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.810819
Longitude: -77.697261

For data sources see[1][2][3]

Well History

Date Event
2018-07-13 New Permit Application
2018-10-11 Performed Spud Operation

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2019 JKLM ENERGY LLC 188,205.00 15 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2019 JKLM ENERGY LLC Produced Fluid 3,340.34 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 JKLM ENERGY LLC Other Oil & Gas Wastes 90.96 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 JKLM ENERGY LLC Produced Fluid 1,476.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 JKLM ENERGY LLC Produced Fluid 38.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 JKLM ENERGY LLC Produced Fluid 1,142.33 Bbl STORAGE PENDING DISPOSAL OR REUSE WMGR123NC038
2019 JKLM ENERGY LLC Synthetic Liner Materials 22.03 Tons LANDFILL 301358
2019 JKLM ENERGY LLC Produced Fluid 31.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 JKLM ENERGY LLC Produced Fluid 8,130.00 Bbl INJECTION DISPOSAL WELL 34-007-23262
2019 JKLM ENERGY LLC Drill Cuttings 782.61 Tons LANDFILL 301358
2019 JKLM ENERGY LLC Other Oil & Gas Wastes 27.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 JKLM ENERGY LLC Other Oil & Gas Wastes 917.34 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 JKLM ENERGY LLC Waste Water Treatment Sludge 61.21 Tons LANDFILL 301358
2019 JKLM ENERGY LLC Soil Contaminated by Oil & Gas Related Spills 28.08 Tons LANDFILL 301358
2019 JKLM ENERGY LLC Produced Fluid 5,396.66 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2781393 Primary Facility 2018-09-28 Preoperation Inspection No Violations Noted The DEP conducted a PRE-SPUD inspection of the JKLM Judson Hollow 302 well pad located in Pike Twp, Potter Co. on 9/28/2018 @ 1330 hours. The weather was 63 degrees, winds NE 9mph,humidity 78%. No personnel were onsite during this inspection.

The site consists of an access road, multi-well pad and associated E&S controls. At the time of this inspection the well pad slopes and topsoil stockpile appeared stabilized by heavy mulch and ~10% vegetative cover of Annual Rye grass. No water was observed in ST-2 off the northern corner of the pad. A small amount of water was observed in ST-1 off the southern side of the pad.

Operator is reminded, a 6" thick layer of compost shall added to the upslope side of any wood chip filter berm located in an HQ watershed. No compost was observed on the chip filter berms during today's inspection.

This inspection meets the requirements of This inspection meets the requirements of 58 Pa. C.S. 3258 (a.1) regarding a "pre-operational inspection".

No violations are noted at

2799239 Primary Facility 2018-11-06 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was conductor only. Pipe is 20" in diameter ad set at a depth of 120'. Conductor pipe was set on 10-11-18 (start) and 10-12-18 (finish) by Butches Rat Hole Service.
2822426 Primary Facility 2019-01-02 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of the JKLM Judson Hollow 302 well pad located in Pike Twp, Potter Co. on 1/2/2018 @1430 hours. The weather was 32 degrees, overcast, winds S @3mph, 78% humidity. Ron Burdick, JKLM Company Man and Jared Jacobini, DEP WQS was present onsite for the inspection. The Falcon rig is currently onsite drilling the vertical portion of 1 marcellus and 3 utica formation wells. At the time of our inspection the rig was at a depth of 300' on the 4HM well.

Puddles were observed in the NE corner of the pad with a field measured conductivity of 2.5 mS/cm. The conductivity decreased as moving away from the area. Fluid in containment had a field measured conductivity of 500uS/cm. The source of the high conductivity fluid could not be located. The Operator representative onsite stated recent truck deliveries were made in the snow and coudl have tracked ice melt onto the site resulting in deposits. The Operator stated he would have a vac truck remove the liquid immediately. No violations

2823051 Primary Facility 2019-01-07 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was vertical drilled only. The conductor casing that is 20" x 120' was set on 10-11-18 thru 10-12-18. The surface casing that is 13 3/8" x 479' was set in the hole on 1-4-19 thru 1-6-19. No violations were noted at this inspection.
2837542 Primary Facility 2019-02-06 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of the JKLM Judson Hollow 302 well pad located in Hector Twp, Potter Co. on 2/6/2019 @1145 hours. The weather was 34 degrees, rain, winds N @10 mph. Ron Burdick, JKLM was present onsite for the inspection.

The top-hole Falcon rig was in the process of preparing to skid over to begin drilling the 3HU well. This is the 3rd of 4 wells planned to be drilled on the pad. Mr. Burdick anticipated being onsite for another 3 weeks.

No violations are noted at this time. I departed the site at 1330.
2838630 Primary Facility 2019-02-05 Drilling/Alteration No Violations Noted At the time of this inspection this well has a conductor (20" outside diameter) and a surface casing (13 3/8" outside diameter) set in the well bore hole. These are the only casings in this wells bore hole at the time of this inspection. No violations noted at this inspection.