If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-105-21590 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.591943,"lon":-77.968124,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Potter | |
Municipality: Sylvania Township | |
Operator Name: PA GEN ENERGY CO LLC | |
Well Pad ID: 149059 | |
Farm/Lease Name: PINE HILL 2383 | |
License Status: Inactive | |
Spud Date: 2009-09-03 | |
Permit Date: 2009-07-31 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.591943 | |
Longitude: -77.968124 |
Date | Event |
---|---|
DEVIATED | |
2009-07-31 | New Permit Application |
2009-09-10 | Performed Spud Operation |
2009-10-06 | Drilling Completion |
2018-11-08 | Inactive Well Request Granted |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2019 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2009 | PA GEN ENERGY CO LLC | Drilling | 3,370.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0102784 |
2010 | PA GEN ENERGY CO LLC | Drilling Fluid Waste | 100.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2010 | PA GEN ENERGY CO LLC | Drilling Fluid Waste | 726.19 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2012 | PA GEN ENERGY CO LLC | Produced Fluid | 169.25 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 850.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 1,520.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 240.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 2,077.50 Bbl | REUSE (AT WELL PAD) | |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 53.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | PA GEN ENERGY CO LLC | Other Oil & Gas Wastes | 50.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 625.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2019 | PA GEN ENERGY CO LLC | Produced Fluid | 55.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | PA GEN ENERGY CO LLC | Other Oil & Gas Wastes | 12.50 Bbl | INJECTION DISPOSAL WELL | PAS2D215BWAR |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1852775 | Primary Facility | 2009-12-30 | Routine/Partial Inspection | Violation(s) Noted | E&S BMPs insufficient, Plan needs revised, no pollution prevention for pollutional substances, impoundment liner staked |
1875137 | Primary Facility | 2010-04-05 | Compliance Evaluation | Violation(s) Noted | Impondment had holes in liner and performed Alternative Waste Disposal without approval |
1897538 | Primary Facility | 2010-07-01 | Routine/Complete Inspection | No Violations Noted | |
2155311 | Primary Facility | 2013-04-10 | Routine/Partial Inspection | No Violations Noted | An inspection of the Pine Hill West Pad B in Sylvania Township, Potter County was conducted on April 10, 2013. The last self-inspection conducted on the behalf of PGE was on 4/3/2013 and no issues were noted. The 2383 well has been drilled, but is not being produced. The 2382 well has been spudded, but not drilled. The site was stabilized and no puddles screened exhibited elevated conductance. No violations were cited during this inspection. |
2593501 | Primary Facility | 2017-05-10 | Routine/Complete Inspection | No Violations Noted | On 5/10/17 at 1248 hrs I conducted a routine inspection at the Pine Hill well site. It was overcast and 60 degrees F. No one was present during my inspection.
The site includes an access road, the well pad and an impoundment. Two wells, the Pine Hill 2382 and 2383, have been drilled and were placed on inactive status on 12/11/13. Drilling of the wells was completed in November 2009; there have been no new well permits issued for the site since that time. It did not appear that the well pad had been restored and the site remains at full size (approximately 300 feet x 475 feet). Also, it did not appear that post-construction stormwater management (PCSM) BMPs have been installed. Interim restoration of the well site should be completed as per 25 Pa Code Section 78a.65(a)(1). On 8/13/15, PGE submitted a Restoration Compliance Report to the Department. The Plan/Schedule for the Pine Hill 2382 site stated that an updated PCSM plan would be submitted to the Department for review and approval within two months. To |
2730903 | Primary Facility | 2018-05-14 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was in Regulatory Inactive Status. |
2740778 | Primary Facility | 2018-06-05 | Routine/Complete Inspection | No Violations Noted | The Department of Environmental Protection conducted a routine inspection of the Pennsylvania General Energy – Pine Hill 2382 (Pine Hill Sylvania Pad B) located in Sylvania Twp., Potter Co. on 6/5/2018 @ 1100 hours. The weather was 65 degrees and overcast.
PGE had set the conductor for the Pine Hill Sylvania, Pad B 2740 well (API#105-21910) on the previous day. Cement was observed at the surface surrounding the conductor pipe. Two existing wells were observed onsite 105-21589 and 105-21590, that are listed as in Regulatory Inactive Status (RIS). John Boardman stated PGE plans to bring a Patterson rig to the site in July to drill the lateral portion of the 2740 well. Waste Management was onsite removing the cuttings, from the top hole portion of the well, that were stockpiled in a waste container adjacent to the well. Onsite PGE representative Cory Dean stated they were in the process of resurfacing the pad. Stone was observed stockpiled along the northern side of the pad. Recent earth disturbance activities |
2745515 | Primary Facility | 2018-06-25 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection the status of this well was Regulatory Inactive Status. |
2762320 | Primary Facility | 2018-08-08 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this wells status was Regulatory Inactive Status. No violations were noted at the time of this inspection. |
2825809 | Primary Facility | 2019-01-11 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was in Regulatory Inactive Status. An inactive extension was granted for this well and this extension will expire on 12-11-19. The annual inactive casing pressure test on this well was conducted on 1-8-19. Results submitted for the testing of this well were noted that the casing pressure was 2350 psi (pounds per square inch). The annular vents are not vented to surface at the well and are hard piped (plumbed) from the well to a production/ waste tank on the pad. Results of the vent testing submitted were 0 psi on the vents. No violations were noted at this inspection. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1852775 | 578718 | 12/30/2009 | 2009-12-30 | 102.4INADPLN - E&S Plan not adequate | Administrative | See Insp ID 1875137 done 4/5/2010, past 102,4INADPLN viol corrected. |
1852775 | 578719 | 12/30/2009 | 2009-12-30 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | See Insp ID 1875137 done 4/5/2010, past 102.4 viol corrected. |
1852775 | 578720 | 12/30/2009 | 2009-12-30 | 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table | Administrative | See Insp ID 1875137 done 4/5/2010, past 78.56PITCNST viol corrected. |
1852775 | 578721 | 12/30/2009 | 2009-12-30 | 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used | Administrative | See Insp ID 1875137 done 4/5/2010, past CSL 691.402(a) danger of pollution to waters created viol corrected. |
1852775 | 578835 | 12/30/2009 | 2009-12-30 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | See Insp ID 1875137 done 4/5/2010, past 78.56(a)(1) pollutional substances not contained in lined pit/tank or series of same viol corrected. |
1852775 | 578836 | 12/30/2009 | 2009-12-30 | 91.34A - Failure to take all necessary measures to prevent spill. Inadequate diking, potential pollution | Environmental Health & Safety | See Insp ID 1875137 done 4/5/2010, past 91.34A viol corrected. |
1875137 | 584601 | 04/05/2010 | 2010-04-05 | 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table | Administrative | See Insp ID 1897538 done 7/1/10, past viols closed. |
1875137 | 584602 | 04/05/2010 | 2010-04-05 | 78.62 - Improper encapsulation of waste | Administrative | See Insp ID 1897538 done 7/1/10, past viols closed. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
578718 | 253918 | NOV - Notice of Violation | Comply/Closed | 2010-04-05 | |||
578719 | 253918 | NOV - Notice of Violation | Comply/Closed | 2010-04-05 | |||
578720 | 253918 | NOV - Notice of Violation | Comply/Closed | 2010-04-05 | |||
578721 | 253918 | NOV - Notice of Violation | Comply/Closed | 2010-04-05 | |||
578835 | 253918 | NOV - Notice of Violation | Comply/Closed | 2010-04-05 | |||
578836 | 253918 | NOV - Notice of Violation | Comply/Closed | 2010-04-05 | |||
584601 | 256639 | NOV - Notice of Violation | Comply/Closed | 2010-07-01 | |||
584602 | 256639 | NOV - Notice of Violation | Comply/Closed | 2010-07-01 |