X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-083-51945

Well Details

Well ID: 37-083-51945
Loading map...
Country: United States
State: Pennsylvania
County: McKean
Municipality: Hamilton Township
Operator Name: SNYDER BROS INC
Well Pad ID:
Farm/Lease Name: LOT 3 48
License Status: ACTIVE
Spud Date:
Permit Date: 2007-01-03
Well Type: OIL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.843341
Longitude: -78.869895

For data sources see[1][2][3]

Well History

Date Event
2007-01-03 New Permit Application
2007-11-29 Performed Spud Operation
2007-12-04 Drilling Completion
2009-02-06 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2008 SNYDER BROS INC 103.56 245 41.61 245 0.00 0
2010 SNYDER BROS INC 0.00 0 0.00 0 0.00 0
2011 SNYDER BROS INC 965.43 331 258.81 331 0.00 0
2012 SNYDER BROS INC 1,962.58 366 395.87 366 0.00 0
2013 SNYDER BROS INC 1,514.76 361 314.81 361 0.00 0
2014 SNYDER BROS INC 1,422.55 365 205.87 365 0.00 0
2015 SNYDER BROS INC 839.82 354 96.33 354 0.00 0
2016 SNYDER BROS INC 712.56 362 81.38 362 0.00 0
2017 SNYDER BROS INC 563.32 365 67.60 364 0.00 0
2018 SNYDER BROS INC 404.97 361 66.54 361 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 SNYDER BROS INC Produced Fluid 6.30 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011 SNYDER BROS INC Produced Fluid 50.65 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0023213
2012 SNYDER BROS INC Produced Fluid 74.91 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0023213
2012 SNYDER BROS INC Produced Fluid 29.01 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2013 SNYDER BROS INC Produced Fluid 20.09 Bbl CENT WASTE TRT FAC NPDES PA0102784
2013 SNYDER BROS INC Produced Fluid 71.04 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0023213
2013 SNYDER BROS INC Produced Fluid 20.09 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0102784
2014 SNYDER BROS INC Produced Fluid 47.72 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0023213
2014 SNYDER BROS INC Produced Fluid 14.04 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0102784
2014 SNYDER BROS INC Produced Fluid 14.04 Bbl CENT WASTE TRT FAC NPDES PA0102784
2016 SNYDER BROS INC Produced Fluid 7.89 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2016 SNYDER BROS INC Produced Fluid 19.47 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0023213
2016 SNYDER BROS INC Produced Fluid 0.79 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SNYDER BROS INC Produced Fluid 26.40 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 SNYDER BROS INC Produced Fluid 5.88 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0023213
2018 SNYDER BROS INC Produced Fluid 24.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SNYDER BROS INC Produced Fluid 5.51 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0023213
2019 SNYDER BROS INC Produced Fluid 15.63 Bbl REUSE AT A CONVENTIONAL WELL SITE IN PA
2019 SNYDER BROS INC Produced Fluid 15.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE BT-008

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1674760 Primary Facility 2007-12-20 Routine/Complete Inspection No Violations Noted
1889817 Primary Facility 2010-06-04 Complaint Inspection Violation(s) Noted
2132744 Primary Facility 2013-01-23 Routine/Complete Inspection No Violations Noted
2770880 Primary Facility 2018-09-05 Complaint Inspection No Violations Noted I received a complaint of a leaking well and gas venting from a tank.

This well had a small leak at the well head and I met Snyder brothers employee who tightened the fitting that was leaking and stopped the leak. The complaint also showed a video of gas escaping from the top of a tank. There are no houses or inhabitants anywhere near this facility. I walked around the perimeter of the tank battery and could smell some gas but it was not detectable on my gas meter and no gas was detected at the well after tightening the fitting. I contacted the complainant with my findings. The regulation, 78.74 says " the venting of gas is to the atmosphere from a well is prohibited when the venting produces a hazard to the public health and safety". There is no threat to public health or safety at this time. - Invalid Complaint Id. - 336678

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1889817 588899 06/04/2010 2010-06-04 401 CSL - Discharge of pollultional material to waters of Commonwealth. Environmental Health & Safety
1889817 591482 06/04/2010 2010-06-04 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
588899 260382 NOV - Notice of Violation Comply/Closed 2010-06-09
591482 260382 NOV - Notice of Violation Comply/Closed 2010-06-09

For data sources see[7]

References