37-081-21744

Well Details

Well ID: 37-081-21744
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Cascade Township
Operator Name: ARD OPR LLC
Well Pad ID: 155230
Farm/Lease Name: ALDEN EVANS A-4H
License Status:
Spud Date:
Permit Date: 2018-05-15
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.435433
Longitude: -76.934681

For data sources see[1][2][3]

Well History

Date Event
2018-05-15 New Permit Application
2018-08-16 Performed Spud Operation

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2019 ARD OPR LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 ARD OPR LLC Produced Fluid 110.00 Bbl REUSE (AT WELL PAD)
2018 ARD OPR LLC Drill Cuttings 60.36 Tons LANDFILL 100955
2018 ARD OPR LLC Drill Cuttings 3,645.02 Tons LANDFILL 301358
2019 ARD OPR LLC Servicing Fluid 48.75 Bbl REUSE (AT WELL PAD)
2019 ARD OPR LLC Produced Fluid 0.75 Bbl REUSE (AT WELL PAD)
2019 ARD OPR LLC Other Oil & Gas Wastes 30.12 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2763010 Primary Facility 2018-08-09 Preoperation Inspection No Violations Noted Pre-Operational Inspection; 8/9/2018.

Perimeter E&S controls are installed and functioning properly. The site is being constructed with base-rocked limestone and geo-textile fabric. Overall, the site is in good condition and fulfills the pre-operational requirement. No violations noted.

2776122 Primary Facility 2018-09-12 Routine/Complete Inspection No Violations Noted Weather was 72 degrees f. and raining at time of inspection. Met with Alta representative Ian Andrews on location. Well was a spud conductor. There was a steel plate covering the casing. The mouse hole was also spud and covered with a steel plate at time of inspection. No violations were noted at time of inspection.
2783196 Primary Facility 2018-10-03 Routine/Complete Inspection No Violations Noted Weather was 62° and cloudy at time of inspection. Met with Alta representative R.D. Mann on location. Well was currently shut in with a night cap. Surface and intermediate casing were drilled and cemented. Wells will be completed after the Brooks 200H. Wells were under the catwalk. Conducted a walk around inspection. No violations were noted at time of inspection.
2792015 Primary Facility 2018-10-18 Routine/Complete Inspection No Violations Noted Weather was 37° and sunny at time of inspection. Met with Alta representative Bill Mitchell on location. Well was currently shut in with a night cap. Surface and intermediate casing were drilled and cemented. Wells were under the catwalk. Conducted a walk around inspection. No violations were noted at time of inspection.
2794399 Primary Facility 2018-10-25 Routine/Complete Inspection No Violations Noted Weather was 45° and partly cloudy at time of inspection. Met with Alta representative R.D. Mann on location. Well was currently shut in with a night cap. Surface and intermediate casing were drilled and cemented. Well was under rig mats. Conducted a walk around inspection. No violations were noted at time of inspection.
2799634 Primary Facility 2018-11-07 Routine/Complete Inspection No Violations Noted Weather was 45° and partly cloudy at time of inspection. Met with Alta representative R.D. Mann on location. Well was currently shut in with a night cap. Surface and intermediate casing were drilled and cemented. Well was under rig mats. Conducted a walk around inspection. No violations were noted at time of inspection.
2804546 Primary Facility 2018-11-19 Routine/Complete Inspection No Violations Noted Weather was 36° and cloudy at time of inspection. Met with Alta representative Bill Michell on location. Well had top hole casing set and cemented. Well was shut in with a night cap. The rig will move to this hole and complete it when they are done with the 3H. Well was covered by the rig at time of inspection. No violations were noted at time of inspection.
2807323 Primary Facility 2018-11-28 Routine/Complete Inspection No Violations Noted Weather was 34° and cloudy at time of inspection. Met with Alta representative R.D. Mann on location. At time of inspection rig was in the process of running in the hole to to begin drilling the curve for the production casing. They estimated to begin drilling the 8 3/4" hole at approximately 12pm. Discussed drilling the curve and lateral for this well. No violations were noted at time of inspection.
2807723 Primary Facility 2018-11-28 Drilling/Alteration Viol(s) Noted & Immediately Corrected The site currently has the FlexRig 225 on location. The rig recently finished drilling the 081-21744 well and will be moving off location soon. The rig manager was informed of a small hydraulic oil spill off containment. The Department recommended the site be cleaned up asap. The operator/rig manager cleaned up the hydraulic spill within the next few hours. The spill is believed to be less than one gallon because the contaminated soil and rock was equal to 1 barrel.

Violations noted but immediately corrected.

The 78.66 violation was entered in error due to the spill being less than 5 gallons.

2817427 Primary Facility 2018-12-19 Routine/Complete Inspection No Violations Noted Weather was 26° and sunny at time of inspection. Met with Alta representative Bill Mitchell on location. Rig had completed drilling the hole to TD. Rig was in the process of running their 5 1/2" 20# production casing in the hole at time of inspection. Rig was estimating to cement in the am on 12/20/18. Rig was floating casing to bottom with an airlock at 9252' from the bottom. They did not want to rupture the airlock early due to previous experience with the Brooks 200H where they felt that was the reason for not being able to get casing to bottom. This rig will move to the Mac Pad after completing this well. No violations were noted at time of inspection.
2826072 Primary Facility 2019-01-07 Routine/Complete Inspection No Violations Noted Weather was 30° and cloudy at time of inspection. There were no Alta representatives on location at time of inspection. Well recently had 3 strings of casing drilled and cemented to TD. Rig had moved off location to the Mac Pad. Well was shut in with a night cap to wait for stimulation. Well was covered with a steel grate at time of inspection. Well cellar was clean and 0% combustible gas was detected at time of inspection. The mouse hole was open and not yet filled with gravel. No violations were noted at time of inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2807723 834392 2018-11-28 2018-11-28 CSL 402(b) Environmental Health & Safety Hydraulic fluid on pad surface.
2807723 834393 2018-11-28 2018-11-28 78.66(a) Environmental Health & Safety Violation entered in error. Spill less than five gallons.
2807723 834394 2018-11-28 2018-11-28 78a54 Environmental Health & Safety Hydraulic fluid spilled to pad surface.

For data sources see[7]