| Well ID: 37-081-21192 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.312447,"lon":-76.889386,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Lycoming | |
| Municipality: Upper Fairfield Township | |
| Operator Name: INFLECTION ENERGY (PA) LLC | |
| Well Pad ID: 145466 | |
| Farm/Lease Name: NATURE BOY SOUTH YODER 2H | |
| License Status: Active | |
| Spud Date: 2013-08-07 | |
| Permit Date: 2013-06-21 | |
| Well Type: GAS | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Conservation: No | |
| Latitude: 41.312447 | |
| Longitude: -76.889386 |
| Date | Event |
|---|---|
| 2013-06-21 | New Permit Application |
| 2013-07-19 | Performed Spud Operation |
| 2013-11-18 | Drilling Completion |
| 2013-12-23 | Perforation |
| 2013-12-23 | Performed Stage 1 of Stimulation |
| 2013-12-24 | Perforation |
| 2013-12-24 | Performed Stage 2 of Stimulation |
| 2013-12-24 | Performed Stage 3 of Stimulation |
| 2013-12-24 | Performed Stage 4 of Stimulation |
| 2013-12-25 | Perforation |
| 2013-12-25 | Performed Stage 5 of Stimulation |
| 2013-12-26 | Perforation |
| 2013-12-26 | Performed Stage 10 of Stimulation |
| 2013-12-26 | Performed Stage 6 of Stimulation |
| 2013-12-26 | Performed Stage 7 of Stimulation |
| 2013-12-26 | Performed Stage 8 of Stimulation |
| 2013-12-26 | Performed Stage 9 of Stimulation |
| 2013-12-27 | Perforation |
| 2013-12-27 | Performed Stage 11 of Stimulation |
| 2013-12-27 | Performed Stage 12 of Stimulation |
| 2013-12-27 | Performed Stage 13 of Stimulation |
| 2013-12-27 | Performed Stage 14 of Stimulation |
| 2013-12-27 | Performed Stage 15 of Stimulation |
| 2013-12-28 | Perforation |
| 2013-12-28 | Performed Stage 16 of Stimulation |
| 2013-12-28 | Performed Stage 17 of Stimulation |
| 2018-03-14 | MOD |
| 2018-05-16 | Deviated |
For data sources see[4]
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 2013-12-23 | 2013-12-28 | 8,583 | 5,796,130 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | WFRA-405e | U.S. Well Services | Friction Reducer | Petroleum Distillates | 64742-47-8 | 20 | 0.01052 | 0 |
| Sodium Chloride | 7647-14-5 | 20 | 0.01315 | 0 | ||||
| SI-1100 | U.S. Well Services | Scale Inhibitor | Copolymer of Maleic and Acrylic acid | 26677-99-6 | 10 | 0.00915 | 0 | |
| 2-Phosphonobutane 1,2,4 tricarboxylic salt | 37971-36-1 | 10 | 0.00213 | 0 | ||||
| DI Water | 7732-18-5 | 80 | 0.01323 | 0 | ||||
| hexamethylenediamine tetra (methylene phosphonic acid) | 38820-59-6 | 10 | 0.00207 | 0 | ||||
| bis (hexamethylene) tramine penta (methylene phosphonic acid) - phosphate acid |
40623-75-4 | 10 | 0.0019 | 0 | ||||
| Ethylene Glycol | 107-21-1 | 40 | 0.00747 | 0 | ||||
| Acrylic polymer | 52255-49-9 | 5 | 0.00083 | 0 | ||||
| Potassium salt of diethylene triamine penta (methylene phosphonic acid) |
15827-60-8 | 10 | 0.00223 | 0 | ||||
| Sand | U.S. Well Services | Proppant | Crystalline silica, quartz | 14808-60-7 | 100 | 11.0769 | 0 | |
| WFRA-405 | U.S. Well Services | Friction Reducer | Anionic Polycrylamide | 62649-23-4 | 40 | 0.00138 | 0 | |
| Water | 7732-18-5 | 40 | 0.00138 | 0 | ||||
| Ethoxylate Alcohol | 68551-12-2 | 5 | 0.00017 | 0 | ||||
| Petroleum Distillates | 64742-47-8 | 22 | 0.00061 | 0 | ||||
| Ammonium Chloride | 12125-02-9 | 5 | 0.00017 | 0 | ||||
| LGC-15 | U.S. Well Services | Gelling Agents | Surfactant | 68439-51-0 | 3 | 0.00056 | 0 | |
| Suspending agent (solid) | 14808-60-7 | 3 | 0.00007000 | 0 | ||||
| Petroleum Distillates | 64742-47-8 | 60 | 0.00878 | 0 | ||||
| Guar Gum | 9000-30-0 | 50 | 0.00109 | 0 | ||||
| K-BAC 1020 | U.S. Well Services | Anti-Bacterial Agent | 2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 20 | 0.00899 | 0 | |
| Polyethylene Glycol | 25322-68-3 | 50 | 0.01027 | 0 | ||||
| Water | 7732-18-5 | 20 | 0.00367 | 0 | ||||
| AP One | U.S. Well Services | Gel Breakers | Ammonium Persulfate | 7727-54-0 | 100 | 0.00043 | 0 | |
| Water | Inflection Energy | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 88.6496 | 0 | |
| AI-301 | U.S. Well Services | Acid Corrosion Inhibitors | Diethylene Glycol | 111-46-6 | 30 | 0.0002 | 0 | |
| Methenamine | 100-97-0 | 20 | 0.00015 | 0 | ||||
| Hydrogen Chloride | 7647-01-0 | 10 | 0.00007000 | 0 | ||||
| Coco Amine | 61791-14-8 | 5 | 0.00003000 | 0 | ||||
| Polyethylene polyamine | 68603-67-8 | 10 | 0.00006000 | 0 | ||||
| HCL Acid (12.5%-18%) | U.S. Well Services | Bulk Acid | Water | 7732-18-5 | 87.5 | 0.1271 | 0 | |
| Hydrogen Chloride | 7647-01-0 | 18 | 0.05287 | 0 |
For data sources see[5]
| Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
|---|---|---|---|---|---|
| 2013-12-23 | 1 | White Sand | 0 | 8,460 | 7,406 |
| 2013-12-24 | 2 | White Sand | 0 | 8,201 | 7,242 |
| 2013-12-24 | 3 | White Sand | 0 | 8,546 | 7,077 |
| 2013-12-24 | 4 | White Sand | 0 | 8,643 | 7,306 |
| 2013-12-25 | 5 | White Sand | 0 | 8,231 | 8,218 |
| 2013-12-26 | 6 | White Sand | 0 | 7,884 | 7,321 |
| 2013-12-26 | 7 | White Sand | 0 | 8,496 | 6,806 |
| 2013-12-26 | 8 | White Sand | 0 | 8,584 | 6,934 |
| 2013-12-26 | 9 | White Sand | 0 | 8,484 | 7,191 |
| 2013-12-26 | 10 | White Sand | 0 | 8,244 | 8,122 |
| 2013-12-27 | 11 | White Sand | 0 | 7,826 | 6,402 |
| 2013-12-27 | 12 | White Sand | 0 | 7,773 | 6,001 |
| 2013-12-27 | 13 | White Sand | 0 | 7,979 | 5,558 |
| 2013-12-27 | 14 | White Sand | 0 | 8,270 | 6,123 |
| 2013-12-27 | 15 | White Sand | 0 | 7,747 | 5,651 |
| 2013-12-28 | 16 | White Sand | 0 | 7,899 | 5,886 |
| 2013-12-28 | 17 | White Sand | 0 | 7,118 | 4,907 |
For data sources see[6]
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2013 | INFLECTION ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2014 | INFLECTION ENERGY (PA) LLC | 1,111,251.00 | 328 | 0.00 | 0 | 0.00 | 0 |
| 2015 | INFLECTION ENERGY (PA) LLC | 714,636.06 | 357 | 0.00 | 0 | 0.00 | 0 |
| 2016 | INFLECTION ENERGY (PA) LLC | 637,970.05 | 360 | 0.00 | 0 | 0.00 | 0 |
| 2017 | INFLECTION ENERGY (PA) LLC | 645,686.00 | 364 | 0.00 | 0 | 0.00 | 0 |
| 2018 | INFLECTION ENERGY (PA) LLC | 485,273.00 | 353 | 0.00 | 0 | 0.00 | 0 |
| 2019 | INFLECTION ENERGY (PA) LLC | 410,453.92 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
| Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|---|
| 2013 | INFLECTION ENERGY LLC | Drilling Fluid Waste | 863.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
| 2014 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 2,816.66 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014 | INFLECTION ENERGY LLC | Drilling Fluid Waste | 863.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
| 2015 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 1,275.90 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 1,070.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 40.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2016 | INFLECTION ENERGY (PA) LLC | Waste Water Treatment Sludge | 4.83 Tons | LANDFILL | 301626 |
| 2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 113.15 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
| 2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 172.68 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
| 2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 582.71 Bbl | REUSE (AT WELL PAD) | |
| 2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 386.95 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 56.14 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
| 2017 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 684.92 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2018 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 644.57 Bbl | REUSE (AT WELL PAD) | |
| 2018 | INFLECTION ENERGY (PA) LLC | Other Oil & Gas Wastes | 292.93 Bbl | REUSE (AT WELL PAD) | |
| 2018 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 37.74 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2019 | INFLECTION ENERGY (PA) LLC | Synthetic Liner Materials | 4.41 Tons | ||
| 2019 | INFLECTION ENERGY (PA) LLC | Other Oil & Gas Wastes | 2.57 Tons | LANDFILL | 100955 |
| 2019 | INFLECTION ENERGY (PA) LLC | Synthetic Liner Materials | 1.26 Tons | LANDFILL | 100955 |
| 2019 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 3.52 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2019 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 89.48 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2019 | INFLECTION ENERGY (PA) LLC | Synthetic Liner Materials | 4.41 Tons | BENEFICIAL REUSE ?PERMIT | |
| 2019 | INFLECTION ENERGY (PA) LLC | Other Oil & Gas Wastes | 57.14 Bbl | REUSE (AT WELL PAD) | |
| 2019 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 404.10 Bbl | REUSE (AT WELL PAD) | |
| 2019 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 20.00 Bbl | RESIDUAL WASTE TRANSFER FACILITY | WMGR123NC039 |
| 2019 | INFLECTION ENERGY (PA) LLC | Produced Fluid | 60.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
| 2019 | INFLECTION ENERGY (PA) LLC | Other Oil & Gas Wastes | 18.57 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
For data sources see[8]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 2230432 | Primary Facility | 2013-12-18 | Routine/Complete Inspection | No Violations Noted | |
| 2266785 | Primary Facility | 2014-04-11 | Drilling/Alteration | No Violations Noted | |
| 2444843 | Primary Facility | 2016-01-26 | Routine/Complete Inspection | No Violations Noted | |
| 2475904 | Primary Facility | 2016-04-07 | Routine/Complete Inspection | No Violations Noted | Inspection to evaluate the FWI de-watering plan submitted on 3/29/2016. Plan indicates water will be discharged to the well pad surface then flow off the pad down a rock lined ditch and discharge into a small vegetated area down the slope. Erosion is a concern at several locations on the site. Along the access road and cut slope, the steep slopes are eroding. The fill slope is not stabilized and it is evident topsoil has been lost at the surface. Water flowing off the pad surface and down the fill slope has caused erosion down the fill slope east of the rock-lined ditch. The site is not permanently stabilized and has rather extensive erosion. It appears that the proposed discharge area does not meet Pa Code § 78.60(5) because the discharge area is not an undisturbed, vegetated area capable of absorbing the water. Also, the erosion caused by water flowing off the well pad raises the concern that Pa Code § 78.53 will not be met during the discharge. The Department does not recommend that the discharge |
| 2489721 | Primary Facility | 2016-06-02 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 6/2/2016.
I entered the site off Tallman Hollow Road at 09:02 and began the inspection. At the time of the inspection, the Nature Boy East Yoder 1H (081-20920), Nature Boy East Unit 2H (081-20921), Nature Boy East Yoder 1V (081-21080), Nature Boy East Yoder 2V (081-21081), Nature Boy East Yoder 3V (081-21082), Nature Boy South Yoder 1H (081-21191), and Nature Boy South Yoder 2H (081-21192) were all in production. A contractor was onsite scarifying, seeding, and stabilizing areas onsite which lacked vegetative cover or showed signs of erosion. The contractor was also re-grading the well pad so that water flows into the rock-lined ditch as designed and not over the fill slope. A sprinkler was set up on the north side of the well pad and had been watering a small section of the cut slope as indicated in the dewatering plan for the Fresh Water Impoundment. No Violations Noted. |
| 2605771 | Primary Facility | 2017-06-20 | Administrative/File Review | Violation(s) Noted | Administrative Inspection entered for the purpose of entering an Enforcement Record (NOV).
VIOLS closed (CRCTD) 3/14/2018 upon issuance of permit modification. |
| 2643325 | Primary Facility | 2017-10-03 | Routine/Complete Inspection | No Violations Noted | Arrived at 15:00. Weather: sunny,nice. 7 producing wells onsite. Note: well labeled Nature Boy East Yoder 3V/5H3H. Routine inspection. No violations observed at this time. |
| 2699733 | Primary Facility | 2018-03-01 | Routine/Complete Inspection | No Violations Noted | Weather was 47° and cloudy with a slight wind at time of inspection. Well has a digital gauge attached to the tubing and the production casing. The gauge on the tubing read 302 psi and the gauge on the casing read 438 psi at time of inspection. There were three anulus vents plumbed to surface. Two of the annulus vents were labeled 20 and 13 and the third annulus vent was unlabeled. There was 0% combustible gas discovered on any of the vents at time of inspection. No violations were noted at time of inspection. |
| 2776883 | Primary Facility | 2018-09-19 | Routine/Complete Inspection | No Violations Noted | Seven wells staged for production phase. Seven each water separators within containment. Dump lines wrapped in insulating blanket. No leaks detected from production equipment. No violations noted. |
| Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
|---|---|---|---|---|---|---|
| 2605771 | 788473 | 2017-06-20 | 2018-03-14 | OGA3211(F1) | Administrative | Well was intentionally drilled at a Surface Hole Location (SHL) other than the approved SHL on the well permit, resulting in the actual SHL being approximately 66 feet from the permitted SHL. |
| 2605771 | 788474 | 2017-06-20 | 2018-03-14 | 78a12 | Administrative | The well was not drilled in accordance with the approved well permit. The actual SHL is approximately 66 feet from the permitted SHL. The maximum True Vertical Depth (TVD) reported in the deviation survey (8,140 feet) exceeds the permitted anticipated TVD (7,906 feet) by 234 feet. The Bottom Hole |
| Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
|---|---|---|---|---|---|---|---|
| 788473 | 354437 | NOV - Notice of Violation | 2018-03-14 | ||||
| 788474 | 354437 | NOV - Notice of Violation | 2018-03-14 |
For data sources see[9]