Well Details

Well ID: 37-081-21126
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Lewis Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 144838
Farm/Lease Name: DCNR 100 101H 51142
License Status:
Spud Date:
Permit Date: 2013-03-21
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.438744
Longitude: -77.030350

For data sources see[1][2][3]

Well History

Date Event
2013-03-21 New Permit Application
2013-04-10 Performed Spud Operation
2013-06-26 New Permit Application
2013-09-27 Drilling Completion
2014-02-16 Perforation
2014-12-31 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-03-14 2014-04-01 8,709 9,148,480 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Proppant 30/50 Ottawa Trican Proppant Crystalline silica (quartz) 14808-60-7 100 5.07182 0
Sl-7 Trican Scale Inhibitor Ethylene glycol 107-21-1 30 0.00810796 0
MBC 516 Trican Biocide Ethanol 64-17-5 2.8 0.00024516 0
Didecyl dimethyl ammonium chloride 7173-51-5 8.3 0.00072673 0
N-alkyl dimethyl benzyl ammonium chloride 68424-85-1 5.5 0.00048157 0
Glutaraldehyde 111-30-8 27 0.00236406 0
7.5% HydroChloric Acid Trican Acid Hydrochloric Acid HCl 7647-01-0 7.5 0.0906282 0
Water Seneca Resources Carrier/Base Fluid Water 7732-18-5 100 88.9135 0
FEAC 20 Trican Iron Control Acetic acid 64-19-7 50 0.00092104 0
Citric acid 77-92-9 30 0.00055263 0
Proppant 40/70 Ottawa Trican Proppant Crystalline silica (quartz) 14808-60-7 100 5.09102 0
FR-15 Trican Friction Reducer Distillates (petroleum), Hydrotreated Light 64742-47-8 25 0.0197207 0
Proprietary Amide Proprietary 2.5 0.00197207 0
AL-7NR Trican Corrosion Inhibitor Prop-2-yn-1-ol 107-19-7 1 0.00002600 0
Proppant 80/100 Oklahoma Trican Proppant Silica 14808-60-7 100 0.79792 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2014 SENECA RESOURCES CO LLC 1,797,457.00 149 0.00 0 0.00 0
2015 SENECA RESOURCES CO LLC 1,969,039.07 287 0.00 0 0.00 0
2016 SENECA RESOURCES CO LLC 1,413,283.24 363 0.00 0 0.00 0
2017 SENECA RESOURCES CO LLC 1,397,802.41 338 0.00 0 0.00 0
2018 SENECA RESOURCES CO LLC 944,573.82 363 0.00 0 0.00 0
2019 SENECA RESOURCES CO LLC 701,152.44 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 SENECA RESOURCES CO LLC Drill Cuttings 1,275.40 Tons RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR097R017
2013 SENECA RESOURCES CO LLC Drill Cuttings 851.73 Tons LANDFILL 301358
2014 SENECA RESOURCES CO LLC Produced Fluid 47.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC012
2014 SENECA RESOURCES CO LLC Produced Fluid 742.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2014 SENECA RESOURCES CO LLC Produced Fluid 10.00 Bbl INJECTION DISPOSAL WELL 34-133-21076
2014 SENECA RESOURCES CO LLC Produced Fluid 14,490.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SENECA RESOURCES CO LLC Produced Fluid 162.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 SENECA RESOURCES CO LLC Servicing Fluid 15.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 SENECA RESOURCES CO LLC Produced Fluid 40.00 Bbl INJECTION DISPOSAL WELL 34-133-20114
2015 SENECA RESOURCES CO LLC Produced Fluid 8.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2015 SENECA RESOURCES CO LLC Produced Fluid 1,483.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Produced Fluid 108.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2016 SENECA RESOURCES CO LLC Produced Fluid 616.86 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 SENECA RESOURCES CO LLC Produced Fluid 11.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SENECA RESOURCES CO LLC Produced Fluid 500.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Soil Contaminated by Oil 18.29 Tons LANDFILL 301358
2017 SENECA RESOURCES CO LLC Soil Contaminated by Oil & Gas Related Spills 18.29 Tons LANDFILL 301358
2017 SENECA RESOURCES CO LLC Produced Fluid 556.50 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Produced Fluid 442.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Produced Fluid 356.00 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 11.00 Bbl REUSE (AT WELL PAD)
2019 SENECA RESOURCES CO LLC Produced Fluid 175.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Produced Fluid 126.00 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 SENECA RESOURCES CO LLC Produced Fluid 26.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC003
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 13.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC003
2019 SENECA RESOURCES CO LLC Produced Fluid 227.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2145701 Primary Facility 2013-02-28 Routine/Complete Inspection No Violations Noted
2156022 Primary Facility 2013-04-09 Routine/Complete Inspection No Violations Noted
2161599 Primary Facility 2013-04-12 Routine/Complete Inspection No Violations Noted Drilling/setting conductor, finishing touches on the well pad Pre-operational insp. ok, NoVio
2252921 Primary Facility 2014-03-10 Routine/Partial Inspection No Violations Noted Frac active, containment good, well maintained site. No Vio.
2259824 Primary Facility 2014-04-03 Routine/Complete Inspection No Violations Noted
2481343 Primary Facility 2016-05-03 Routine/Complete Inspection No Violations Noted
2597628 Primary Facility 2017-05-18 Routine/Complete Inspection No Violations Noted Routine inspection of unconventional well in production. No violations noted at time of inspection.
2635314 Primary Facility 2017-08-30 Incident- Response to Accident or Event No Violations Noted Spill response inspection.

On 8/29/2017, Doug Kepler (Seneca)contacted me at 12:59 concerning a release of produced water from a flow line adjacent to the production tanks on the site. Mr. Kepler reported that the produced water line washed-out at a 90 (degree angle) and was discovered at approximately 12:00. At 13:18, I called Kyle Kline (Seneca) to discuss the release. Mr. Kline reported the surface area of the release was approximately 15'X20'. Mr. Kline estimate the volume of the release to be about 1 barrel. I asked Mr. Kline to call after the cleanup began to evaluate the volume estimate and to coordinate a site meeting. Mr. Kline called at 16:38 and said the excavation was almost complete. We agreed to meet the following day.

At 12:15 on 8/30/2017, I arrived onsite and met with Mr. Kline. Onsite I found the breached pipe was fixed and an excavation about 20'X20' approximately 5 feet deep was open around the pipe. A "spoils pile" was located adjacent to the excavation which was allegedly not

2635359 Primary Facility 2017-09-06 Incident- Response to Accident or Event No Violations Noted Follow-up inspection.

Clark Smith (DEP) and I entered the site to evaluate the excavation and remediation if the release reported to the Department on 8/29/2017. Field soil conductivity was between 90-1,650 umhos/cm throughout the entire excavation. The area depicted in photo #2 had the highest conductivity. This small area was also the only area over 1,000 umhos/cm anywhere in the excavation or in the area adjacent to the excavation. Mr. Smith discussed the sampling requirements with the operator before our site inspection. The consultant provided field screening and confirmation sample figures(see photos). The Department is awaiting confirmation sample results. Previous violations cited to ESX12-081-0138 remain outstanding, no new violations noted.

2807047 Primary Facility 2018-11-27 Routine/Complete Inspection No Violations Noted Ten wells staged for production. Ten GPU within shallow (6 inch) containment. Glycol heater cart in use for heating of the dump and transfer lines around the GPU. No leaks detected. Site stable. No violations.

For data sources see[8]