If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-21108 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.419094,"lon":-77.059347,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Lewis Township | |
Operator Name: SENECA RESOURCES CO LLC | |
Well Pad ID: 145506 | |
Farm/Lease Name: DCNR 100 57H 50883 | |
License Status: | |
Spud Date: | |
Permit Date: 2012-12-27 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 41.419094 | |
Longitude: -77.059347 |
Date | Event |
---|---|
2012-12-27 | New Permit Application |
2013-06-21 | New Permit Application |
2013-07-07 | Performed Spud Operation |
2013-09-28 | Drilling Completion |
2013-12-21 | Perforation |
2014-12-31 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-01-09 | 2014-02-11 | 8,929 | 6,899,210 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | MBC 516 | Trican | Biocide | Glutaraldehyde | 111-30-8 | 27 | 0.00223964 | 0 |
Didecyl dimethyl ammonium chloride | 7173-51-5 | 8.3 | 0.00068848 | 0 | ||||
N-alkyl dimethyl benzyl ammonium chloride | 68424-85-1 | 5.5 | 0.00045622 | 0 | ||||
Ethanol | 64-17-5 | 2.8 | 0.00023226 | 0 | ||||
Proppant 40/70 Ottawa | Trican | Proppant | Crystalline silica (quartz) | 14808-60-7 | 100 | 5.19284 | 0 | |
FR-15 | Trican | Friction Reducer | Proprietary Amide | Proprietary | 2.5 | 0.0017631 | 0 | |
Distillates (petroleum), Hydrotreated Light | 64742-47-8 | 25 | 0.017631 | 0 | ||||
7.5% HydroChloric Acid | Trican | Acid | Hydrochloric Acid HCl | 7647-01-0 | 7.5 | 0.0827164 | 0 | |
Gyptron T-390 | Champion Technologies | Scale Inhibitor | Methanol | 67-56-1 | 10 | 0.00008355 | 0 | |
Nonylphenol Ethoxylate | Proprietary | 10 | 0.00008355 | 0 | ||||
Sl-7 | Trican | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30 | 0.0072843 | 0 | |
Proppant 30/50 Ottawa | Trican | Proppant | Crystalline silica (quartz) | 14808-60-7 | 100 | 5.12259 | 0 | |
Bactron K-219 | Champion Technologies | Biocide | Quaternary Ammonium Compounds, Benzyl-C12-16-alkidimethyl, Chlorides |
68424-85-1 | 20 | 0.0002985 | 0 | |
Methanol | 67-56-1 | 45 | 0.00067163 | 0 | ||||
Glutaraldehyde | 111-30-8 | 75 | 0.00111938 | 0 | ||||
FEAC 20 | Trican | Iron Control | Citric acid | 77-92-9 | 30 | 0.0005051 | 0 | |
Acetic acid | 64-19-7 | 50 | 0.00084184 | 0 | ||||
Bactron K-176 | Champion Technologies | Biocide | 1-Decanaminium, N-decyl-N,N-dimethyl-, chloride | 7173-51-5 | 10 | 0.00008106 | 0 | |
Glutaraldehyde | 111-30-8 | 30 | 0.00024318 | 0 | ||||
Quaternary ammonium compounds, benzyl-C12-16- alkyldimethyl, chlorides |
68424-85-1 | 10 | 0.00008106 | 0 | ||||
Ethanol | 64-17-5 | 5 | 0.00004053 | 0 | ||||
Water | Seneca Resources | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 88.7681 | 0 | |
FlowPlus DR-5018 | Champion Technologies | Friction Reducer | Acrylamide | 79-06-1 | 0.1 | 0.00000732 | 0 | |
Hydrotreated Light Distillates | 64742-47-8 | 30 | 0.0021958 | 0 | ||||
Sorbitan Monoleate | 1338-43-8 | 5 | 0.00036597 | 0 | ||||
AL-7NR | Trican | Corrosion Inhibitor | Prop-2-yn-1-ol | 107-19-7 | 1 | 0.00002378 | 0 | |
Proppant 80/100 Oklahoma | Trican | Proppant | Silica | 14808-60-7 | 100 | 0.796822 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | SENECA RESOURCES CO LLC | 2,298,359.00 | 211 | 0.00 | 0 | 0.00 | 0 |
2015 | SENECA RESOURCES CO LLC | 1,650,375.30 | 253 | 0.00 | 0 | 0.00 | 0 |
2016 | SENECA RESOURCES CO LLC | 1,203,835.30 | 311 | 0.00 | 0 | 0.00 | 0 |
2017 | SENECA RESOURCES CO LLC | 1,122,022.57 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | SENECA RESOURCES CO LLC | 766,659.63 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | SENECA RESOURCES CO LLC | 591,408.91 | 324 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | SENECA RESOURCES CO LLC | Drill Cuttings | 1,154.33 Tons | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR097R017 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 11.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 25.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 9,814.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 310.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 3.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 17.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 443.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 66.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 25.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 657.96 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 531.64 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 943.96 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 351.42 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 34.28 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 557.84 Bbl | REUSE (AT WELL PAD) | |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 43.46 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 37.00 Bbl | RESIDUAL WASTE TRANSFER FACILITY | WMGR123NC039 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 77.08 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2019 | SENECA RESOURCES CO LLC | Waste Water Treatment Sludge | 29.75 Tons | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2019 | SENECA RESOURCES CO LLC | Synthetic Liner Materials | 4.66 Tons | LANDFILL | 301358 |
2019 | SENECA RESOURCES CO LLC | Drilling Fluid Waste | 6.03 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 100.84 Bbl | REUSE (AT WELL PAD) | |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 18.57 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC003 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 34.80 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 515.33 Bbl | RESIDUAL WASTE TRANSFER FACILITY | WMGR123NC039 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 1,484.25 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 474.44 Bbl | STORAGE PENDING DISPOSAL OR REUSE | WMGR123NC038 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 14.29 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 35.77 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 917.63 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2194970 | Primary Facility | 2013-08-12 | Drilling/Alteration | No Violations Noted | |
2240283 | Primary Facility | 2014-01-27 | Drilling/Alteration | No Violations Noted | |
2243276 | Primary Facility | 2014-01-30 | Routine/Partial Inspection | No Violations Noted | Trican-frac job, under pressure on the 55H, wireline on 60H. No Vio |
2252909 | Primary Facility | 2014-03-10 | Routine/Partial Inspection | No Violations Noted | drilling out plugs, frac crew offsite, containment good, field conductivity good. No Vio. |
2288836 | Primary Facility | 2014-07-22 | Routine/Complete Inspection | No Violations Noted | |
2481231 | Primary Facility | 2016-05-03 | Routine/Complete Inspection | No Violations Noted | |
2597039 | Primary Facility | 2017-05-18 | Routine/Complete Inspection | No Violations Noted | Routine inspection of unconventional well in production. Well tag noted in inspection report as being incorrect. No violations noted at time of inspection. |
2612580 | Primary Facility | 2017-07-05 | Routine/Complete Inspection | No Violations Noted | |
2814500 | Primary Facility | 2018-12-13 | Routine/Complete Inspection | No Violations Noted | Weather was 35° and cloudy at time of inspection. Met with Seneca resources representative Rod Mills on location. Well was covered with a steel cage due to drilling operations on location. Well had digital pressure monitoring equipment attached to the production casing and the production tubing. Casing pressure was 331 psi and tubing pressure was 255 psi at time of inspection. There were 3 annulus vent plumbed to surface at time of inspection. 0% combustible gas was detected on the annulus vents at time of inspection. No violations were noted at time of inspection. |
For data sources see[8]