X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-081-20998

Well Details

Well ID: 37-081-20998
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Lewis Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 145123
Farm/Lease Name: DCNR 100 68H 51104
License Status:
Spud Date:
Permit Date: 2012-07-17
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.429914
Longitude: -77.058167

For data sources see[1][2][3]

Well History

Date Event
2012-07-17 New Permit Application
2013-01-02 Performed Spud Operation
2013-03-12 Drilling Completion
2013-09-10 Perforation
2014-06-11 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-10-17 2013-11-04 8,932 4,544,570 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Seneca Resources Carrier/Base Fluid Water 7732-18-5 100 88.256 0
Bactron K-176 Champion Technologies Biocide 1-Decanaminium, N-decyl-N,N-dimethyl-, chloride 7173-51-5 10 0.0027161 0
Quaternary ammonium compounds,
benzyl-C12-16-

alkyldimethyl, chlorides

68424-85-1 10 0.0027161 0
Glutaraldehyde 111-30-8 30 0.00814829 0
Ethanol 64-17-5 5 0.00135805 0
Gyptron T-390 Champion Technologies Scale Inhibitor Nonylphenol Ethoxylate Proprietary 10 0.00104041 0
Methanol 67-56-1 10 0.00104041 0
7.5% HydroChloric Acid Universal Well Services Acid Hydrochloric Acid HCl 7647-01-0 7.5 0.0969691 0
Proppant 30/50 Ottawa Universal Well Services Proppant Silica 14808-60-7 100 5.33434 0
Proppant 40/70 Ottawa Universal Well Services Proppant Silica 14808-60-7 100 5.37709 0
Iron Stabilizer II Universal Well Services Corrosion Inhibitor Ethylene Glycol 107-21-1 30 0.00058642 0
FlowPlus DR-5018 Champion Technologies Friction Reducer Sorbitan Monoleate 1338-43-8 5 0.00438599 0
Acrylamide 79-06-1 0.1 0.00008772 0
Hydrotreated Light Distillates 64742-47-8 30 0.0263159 0
Proppant 80/100 Oklahoma Universal Well Services Proppant Silica 14808-60-7 100 0.886572 0
Unihib G Universal Well Services Corrosion Inhibitor Ethoxylated Alcohol Proprietary 35 0.00017372 0
Resin Based Nonionic Inhibitor Proprietary 35 0.00017372 0
Glycol Ether 112-34-5 50 0.00024817 0
CFT-1200 Core Labs Chemical Tracer Water 7732-18-5 90 0.00003741 0
Proprietary Ingredient supplied as 10% w/vAqueous Solution Proprietary 10 0.00000416 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2013 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2014 SENECA RESOURCES CO LLC 1,501,620.60 342 0.00 0 0.00 0
2015 SENECA RESOURCES CO LLC 888,549.53 348 0.00 0 0.00 0
2016 SENECA RESOURCES CO LLC 724,235.62 275 0.00 0 0.00 0
2017 SENECA RESOURCES CO LLC 642,376.39 365 0.00 0 0.00 0
2018 SENECA RESOURCES CO LLC 498,289.14 363 0.00 0 0.00 0
2019 SENECA RESOURCES CO LLC 431,210.63 330 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 SENECA RESOURCES CO LLC Drill Cuttings 1,158.51 Tons LANDFILL 301358
2014 SENECA RESOURCES CO LLC Produced Fluid 9,701.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SENECA RESOURCES CO LLC Produced Fluid 42.00 Bbl INJECTION DISPOSAL WELL 34-133-20114
2015 SENECA RESOURCES CO LLC Produced Fluid 219.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 SENECA RESOURCES CO LLC Produced Fluid 831.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Produced Fluid 131.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2016 SENECA RESOURCES CO LLC Produced Fluid 1,305.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 SENECA RESOURCES CO LLC Produced Fluid 155.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SENECA RESOURCES CO LLC Produced Fluid 453.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Produced Fluid 650.09 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Synthetic Liner Materials 1.79 Tons LANDFILL 301358
2018 SENECA RESOURCES CO LLC Produced Fluid 540.33 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 36.67 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Produced Fluid 379.35 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 41.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Produced Fluid 237.51 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 5.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 18.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC003
2019 SENECA RESOURCES CO LLC Produced Fluid 108.33 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 SENECA RESOURCES CO LLC Produced Fluid 236.67 Bbl REUSE (AT WELL PAD)
2019 SENECA RESOURCES CO LLC Produced Fluid 21.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC003

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2114102 Primary Facility 2012-11-07 Routine/Partial Inspection No Violations Noted
2120881 Primary Facility 2012-11-30 Routine/Complete Inspection No Violations Noted
2122337 Primary Facility 2012-12-10 Drilling/Alteration No Violations Noted
2128352 Primary Facility 2012-12-28 Routine/Complete Inspection No Violations Noted
2129952 Primary Facility 2013-01-09 Routine/Complete Inspection No Violations Noted
2140546 Primary Facility 2013-02-14 Routine/Complete Inspection No Violations Noted
2144098 Primary Facility 2013-02-26 Drilling/Alteration No Violations Noted
2194912 Primary Facility 2013-08-12 Routine/Complete Inspection No Violations Noted
2221235 Primary Facility 2013-11-13 Routine/Complete Inspection No Violations Noted
2288862 Primary Facility 2014-07-22 Routine/Complete Inspection No Violations Noted
2481079 Primary Facility 2016-05-03 Routine/Complete Inspection No Violations Noted
2596114 Primary Facility 2017-05-18 Routine/Complete Inspection No Violations Noted Routine inspection of unconvnetional well in production. No violations noted at time of inspection.
2613498 Primary Facility 2017-07-05 Routine/Complete Inspection No Violations Noted Weather: hot and sunny. Arrived @ 14:50. Seven wells total: Six wells capable of production and one plugged well. The 9-5/8” x 5-1/2” vents were shut-in. Within the cellar, this annulus was also plumbed into a 2” flexible hose which appeared to link each of the vents to a 2100-gallon poly tank. Left @ 15:10. There were no violations at this time.

117H: 5-1/2” gauge: 467 psi (digital)

53H: 5-1/2” gauge:  427.6 psi (digital)
54H:  5-1/2” gauge: 433.1 psi (digital)
68H: 5-1/2” gauge:  410 psi (digital)
50H: plugged well, gravel-filled cellar, one candy cane vent. Monitored for methane: 0% (Altair 5X calibrated 7/5/17). 
51H: 5-1/2” gauge:  377 psi (digital)
52H: 5-1/2” gauge: 560 psi (digital).

Left @ 15:10

2815984 Primary Facility 2018-12-13 Routine/Complete Inspection No Violations Noted Weather was 35° and cloudy at time of inspection. There were no Seneca resources representatives on location at time of inspection. Well had digital pressure monitoring equipment attached to the production casing and the production tubing. Casing pressure was 301 psi and tubing pressure was 245 psi at time of inspection. There were 3 annulus vents plumbed to surface at time of inspection. The 20x13 and 13x9 annulus had 0% combustible gas detected. The 9x5 annulus had 8% methane detected at time of inspection. No violations were noted at time of inspection.

For data sources see[8]

References