{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.434256,"lon":-77.039422,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Lewis Township | |
Operator Name: SENECA RESOURCES CO LLC | |
Well Pad ID: 150186 | |
Farm/Lease Name: DCNR 100 42H 50856 | |
License Status: | |
Spud Date: | |
Permit Date: 2012-06-19 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.434256 | |
Longitude: -77.039422 |
Date | Event |
---|---|
2012-06-19 | New Permit Application |
2012-10-03 | Performed Spud Operation |
2013-01-15 | Drilling Completion |
2013-02-18 | Perforation |
2014-02-25 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-03-06 | 2013-03-06 | 8,920 | 7,432,908 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Proppant 40/70 Ottawa | Universal Well Services | Proppant | Silica | 14808-60-7 | 100.0 | 5.24666 | |
Bactron K-176 | Champion Technologies | Biocide | 1-Decanaminium, N-decyl-N,N-dimethyl-, chloride | 7173-51-5 | 10.0 | 0.00279 | ||
Quaternary ammonium compounds, benzyl-C12-16- alkyldimethyl, chlorides |
68424-85-1 | 10.0 | 0.00279 | |||||
Glutaraldehyde | 111-30-8 | 30.0 | 0.00836 | |||||
Ethanol | 64-17-5 | 5.0 | 0.00139 | |||||
Iron Stabilizer II | Universal Well Services | Corrosion Inhibitor | Ethylene Glycol | 107-21-1 | 30.0 | 0.00046 | ||
Gyptron T-390 | Champion Technologies | Scale Inhibitor | Nonylphenol Ethoxylate | Proprietary | 10.0 | 0.00096 | ||
Methanol | 67-56-1 | 10.0 | 0.00096 | |||||
FlowPlus DR-5018 | Champion Technologies | Friction Reducer | Acrylamide | 79-06-1 | 0.1 | 0.00008000 | ||
Sorbitan Monoleate | 1338-43-8 | 5.0 | 0.00421 | |||||
Hydrotreated Light Distillates | 64742-47-8 | 30.0 | 0.02524 | |||||
Proppant 30/50 Ottawa | Universal Well Services | Proppant | Silica | 14808-60-7 | 100.0 | 5.28899 | ||
Proppant 80/100 Oklahoma | Universal Well Services | Proppant | Silica | 14808-60-7 | 100.0 | 0.85815 | ||
7.5 HydroChloric Acid | Universal Well Services | Acid | Hydrochloric Acid HCl | 7647-01-0 | 7.5 | 0.07657 | ||
Unihib G | Universal Well Services | Corrosion Inhibitor | Ethoxylated Alcohol | Proprietary | 35.0 | 0.00014 | ||
Glycol Ether | 112-34-5 | 50.0 | 0.0002 | |||||
Resin Based Nonionic Inhibitor | Proprietary | 35.0 | 0.00014 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SENECA RESOURCES CO LLC | 2,333,552.00 | 210 | 0.00 | 0 | 0.00 | 0 |
2014 | SENECA RESOURCES CO LLC | 1,711,158.70 | 260 | 0.00 | 0 | 0.00 | 0 |
2015 | SENECA RESOURCES CO LLC | 1,560,594.32 | 364 | 0.00 | 0 | 0.00 | 0 |
2016 | SENECA RESOURCES CO LLC | 1,138,649.15 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | SENECA RESOURCES CO LLC | 840,953.59 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | SENECA RESOURCES CO LLC | 654,113.72 | 363 | 0.00 | 0 | 0.00 | 0 |
2019 | SENECA RESOURCES CO LLC | 524,864.91 | 364 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SENECA RESOURCES CO LLC | Drill Cuttings | 97.07 Tons | LANDFILL | 301358 |
2013 | SENECA RESOURCES CO LLC | Produced Fluid | 8,298.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SENECA RESOURCES CO LLC | Drill Cuttings | 1,580.51 Tons | LANDFILL | 301358 |
2013 | SENECA RESOURCES CO LLC | Produced Fluid | 326.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC012 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 3.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC012 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 40.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 3192 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 11.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 4.00 Bbl | INJECTION DISPOSAL WELL | 34-133-21076 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 6,131.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 22.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 612.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 90.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 2,032.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 69.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 987.89 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 23.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SENECA RESOURCES CO LLC | Synthetic Liner Materials | 4.78 Tons | LANDFILL | 301358 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 774.05 Bbl | REUSE (AT WELL PAD) | |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 587.42 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 283.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 271.09 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 12.22 Bbl | REUSE (AT WELL PAD) | |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 43.33 Bbl | RESIDUAL WASTE TRANSFER FACILITY | WMGR123NC039 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 83.89 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 14.44 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC003 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 201.09 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2089926 | Primary Facility | 2012-08-03 | Routine/Complete Inspection | No Violations Noted | |
2112975 | Primary Facility | 2012-11-01 | Routine/Partial Inspection | No Violations Noted | |
2122384 | Primary Facility | 2012-12-10 | Drilling/Alteration | No Violations Noted | |
2129958 | Primary Facility | 2013-01-09 | Routine/Complete Inspection | No Violations Noted | |
2225635 | Primary Facility | 2013-12-02 | Routine/Complete Inspection | No Violations Noted | |
2240332 | Primary Facility | 2014-01-27 | Drilling/Alteration | No Violations Noted | |
2713784 | Primary Facility | 2018-03-26 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 3/26/2018.
At the time of the inspection, 9 wells were in production. The PCSM has been implemented but is not functioning as designed. The fresh water impoundment has been removed and the area reclaimed. I recommend reviewing the implementation of the PCSM. No violations noted. |
2808233 | Primary Facility | 2018-11-29 | Routine/Complete Inspection | No Violations Noted | Nine wells staged for production. Nine GPUs within 10 inch polyurethane coated Styrofoam containment. No leaks from production equipment.
A well site restoration period extension request was submitted on 10/26/2018. The request will be returned due to PCSM issues. |