If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20865 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.237408,"lon":-76.620592,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Franklin Township | |
Operator Name: EXCO RESOURCES PA LLC | |
Well Pad ID: 147873 | |
Farm/Lease Name: BUDMAN 4H | |
License Status: Plugged and Abandoned | |
Spud Date: | |
Permit Date: 2012-03-14 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.237408 | |
Longitude: -76.620592 |
Date | Event |
---|---|
2012-03-14 | New Permit Application |
2012-05-21 | New Permit Application |
2012-05-21 | Performed Spud Operation |
2015-12-30 | New Permit Application |
2018-05-10 | Begin Plugging |
2018-05-10 | Finished Plugging |
2018-09-25 | Fully Plugged |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | EXCO RESOURCES PA LLC | Drill Cuttings | 14.34 Tons | LANDFILL | 301358 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2065770 | Primary Facility | 2012-05-07 | Routine/Complete Inspection | No Violations Noted | |
2072649 | Primary Facility | 2012-06-01 | Drilling/Alteration | No Violations Noted | |
2098765 | Primary Facility | 2012-09-11 | Routine/Partial Inspection | No Violations Noted | |
2110539 | Primary Facility | 2012-10-24 | Routine/Complete Inspection | No Violations Noted | |
2433622 | Primary Facility | 2015-12-14 | Routine/Complete Inspection | No Violations Noted | Arrived @ 14:00. Weather: unseasonably hot. There were three filled cellars and one conductor-only spud on this location. The Budman 4H (081-20865) was spudded on 5/21/2015, suggesting that the appropriate permit for the conductor-only spud is 081-20865. This permit was issued on 3/14/2012 and expired a year later. |
2482891 | Primary Facility | 2016-05-03 | Routine/Complete Inspection | No Violations Noted | |
2560392 | Primary Facility | 2017-02-08 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 2/8/2017.
I entered the location at 11:50 and began the inspection. At the time of the inspection, the well pad was being used as storage for trucks and farm equipment. An impoundment remains excavated but never had a liner installed. In addition, a tank pad was permitted in the first revision but was never constructed. The spud date for the Budman 4H (081-20865) was 5/21/2012 and only conductor was set. No other drilling was ever initiated. The well permit expired on 12/30/2016. The ESCGP expires on 9/27/2017 and has not been constructed as designed. The Department interprets Section 3216(c) of the 2012 Oil and Gas Act to mean that post drilling restoration includes the restoration of freshwater impoundments. Freshwater impoundments must be restored within 9 months of completion of drilling the last well served by the impoundment or expiration of the last well permit that the impoundment was intended to service. Currently, the site does not account for PCSM and has not been res |
2601855 | Primary Facility | 2017-06-05 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 6/5/2017.
I entered the site at 15:14 off Cemetery Road. At the time of the inspection, the fresh water impoundment was backfilled and reclaimed. Topsoil was being moved from the topsoil stockpile and spread. The Budman 4H (081-20865) has only conductor set and the spud date was 5/21/2012. Perimeter E&S controls were installed and functioning properly. No violations noted. |
2728620 | Primary Facility | 2018-05-10 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | A routine inspection of the Budman 4H well (conductor only) was conducted May 10th, 2018. The operator has submitted a Notice of Intent to plug for this conductor which indicated plugging was scheduled for today. The contractor on location confirmed the conductor was just plugged before I arrived. The well was capped with a marker plate with the permit number. The well will be buried and the site reclaimed. No obvious issues were observed. |
2832718 | Primary Facility | 2019-01-28 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | On January 28, 2019, Department representative Brad Kline conducted a routine site inspection at EXCO Resources LLC. Budman Pad. No E&S issues were observed during the time of inspection. The site is stable and well vegetated meeting the 70% uniform, perennial, vegetative cover. Well pad has been reclaimed. The Department recommends submitting a Notice of Termination and a Post-plugging Well Site Restoration Report when weather conditions permit.
No violation noted. |
For data sources see[7]