X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-081-20790

Well Details

Well ID: 37-081-20790
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Penn Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 148937
Farm/Lease Name: MYERS UNIT 7H
License Status:
Spud Date:
Permit Date: 2011-12-08
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.298469
Longitude: -76.606406

For data sources see[1][2][3]

Well History

Date Event
2011-12-08 New Permit Application
2011-12-13 Performed Spud Operation
2012-03-23 New Permit Application
2012-06-19 Drilling Completion
2012-09-05 Perforation
2013-08-23 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-09-05 2012-09-05 7,863 3,855,491

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Hydrochloric Acid Calfrac Well Services Clean Perforations Propargyl Alcohol 10.00 0.00014000
Fatty acids 30.00 0.00043000
Ammonium chloride 12125-02-9 10.00 0.00120000
Thiourea polymer 68527-49-1 30.00 0.00043000
Polyethylene glycol 25322-68-3 70.00 0.01
Sodium chloride 7647-14-5 1.00 0.00001000
Polyoxyalkylenes 30.00 0.00043000
Goethite 1310-14-1 0.10 0.00551000
Carbonic acid calcium salt (1:1) 471-34-1 1.00 0.02
Biotite 1302-27-8 0.10 0.00268000
Apatite 64476-38-6 0.10 0.00268000
Olefin 5.00 0.00007000
Acetic acid 64-19-7 1.00 0.00020000
Oxyalkylated polyamine 5.00 0.00100000
Amine salt 5.00 0.00100000
Hydrochloric acid 7647-01-0 37.00 0.30
Polyacrylamide polymer 40.00 0.04
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 40.00 0.01
Ilmenite (FeTiO3), conc. 98072-94-7 0.10 0.00126000
Nonionic surfactant 5.00 0.00512000
Formalin 50-00-0 0.10 0.00003000
Organic phosphonate 2 10.00 0.00199000
Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
Polyoxyalkylenes surfactant 5.00 0.00512000
Organic phosphonate 1 30.00 0.00598000
Methanol 67-56-1 60.00 0.00683000
Illite 12173-60-3 1.00 0.00341000
Quartz 14808-60-7 100.00 15.36
Citric acid 77-92-9 60.00 0.00300000
DWP-944 Calfrac Well Services Biocide
Sand (Proppant) Calfrac Well Services Propping Agent
DWP-612 Calfrac Well Services Friction Reducer
Water BaseFluid/Mix Water Water 7732-18-5 100.00 84.20
DAP-925 Calfrac Well Services Acid Corrosion Inhibitor
DAP-901 Calfrac Well Services Scale Inhibitor
DAP-103 Calfrac Well Services Iron Control

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 11,376.00 31 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 1,132,970.00 365 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 1,061,498.00 365 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 890,277.00 349 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 690,925.00 306 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 704,723.00 337 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 663,664.00 364 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 563,332.00 363 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 EXCO RESOURCES PA LLC Drilling Fluid Waste 422.38 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2011 EXCO RESOURCES PA LLC Drilling Fluid Waste 2,695.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EXCO RESOURCES PA LLC Produced Fluid 249.99 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EXCO RESOURCES PA LLC Drilling Fluid Waste 3,520.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EXCO RESOURCES PA LLC Fracing Fluid Waste 5,480.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EXCO RESOURCES PA LLC Drill Cuttings 473.43 Tons LANDFILL 301358
2012 EXCO RESOURCES PA LLC Fracing Fluid Waste 1,028.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 EXCO RESOURCES PA LLC Produced Fluid 71.40 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 EXCO RESOURCES PA LLC Produced Fluid 126.19 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2014 EXCO RESOURCES PA LLC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2015 EXCO RESOURCES PA LLC Produced Fluid 110.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2015 EXCO RESOURCES PA LLC Produced Fluid 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EXCO RESOURCES PA LLC Produced Fluid 220.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC Produced Fluid 183.40 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid 82.70 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid 12.30 Bbl REUSE (AT WELL PAD)
2018 EXCO RESOURCES PA LLC Produced Fluid 10.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EXCO RESOURCES PA LLC Produced Fluid 71.40 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019 EXCO RESOURCES PA LLC Produced Fluid 55.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2058194 Primary Facility 2012-04-05 Routine/Partial Inspection Viol(s) Noted & Immediately Corrected
2060854 Primary Facility 2012-04-19 Routine/Complete Inspection No Violations Noted
2062507 Primary Facility 2012-04-20 Routine/Complete Inspection No Violations Noted
2077330 Primary Facility 2012-06-14 Routine/Complete Inspection No Violations Noted
2086307 Primary Facility 2012-07-19 Routine/Complete Inspection No Violations Noted
2110556 Primary Facility 2012-10-24 Routine/Complete Inspection No Violations Noted
2117077 Primary Facility 2012-11-20 Routine/Complete Inspection No Violations Noted
2469552 Primary Facility 2016-03-25 Routine/Complete Inspection No Violations Noted At the time of the inspection, the Myers Unit 1H (081-20279) and 7H (081-20790 were in production. The well pad area was relatively well vegetated but some erosion of gravel off the well pad surface (photo attached) was noted. The well site has not been restored and the Well Site Compliance Information Request reply (submitted 9/21/2015) says the well site was permitted under an ESCGP-1 and a new drilling permit will be submitted in the fall of 2015. The Department has no record of an ESCGP issued for the site and no well permits have been issued for the site since 12/8/2011. The Department’s records indicate five active wells exist on the site, however, only the two wells mentioned above were located on the pad. The well pad remains at its original size. I recommend you apply for an ESCGP-2 to cover this since it has not been restored and was part of a larger disturbance. Please also provide an update on the status of the three active wells that were not found onsite.
2493186 Primary Facility 2016-06-09 Routine/Complete Inspection No Violations Noted
2505482 Primary Facility 2016-07-27 Routine/Complete Inspection No Violations Noted Arrived @ 15:00. Weather: hot. Met with Bird Smith (EXCO), also onsite was a Guzzler vac truck (Fast Rig Support), and Greg Miller (Catawater). At the time of my arrival workers had already sucked open the cellar of the Myers 2H, revealing two annular pipes, and a vent for the 9-5/8”. They were determining what piping would be needed to vent the annuli at the surface. While I was onsite, the cellar of the 3H was partially sucked out. The arrangement of the annular pipes was similar. The plan was to finish the work on 7/28/16 and leave the annular vents open.

There were also two completed wells on location the Myers 1H, which was shut-in, and Myers 7 H which was in production. No violations were apparent at the time of this inspection. Left location @ 16:10.

2509299 Primary Facility 2016-07-29 Routine/Complete Inspection No Violations Noted Arrived @ 08:30. Weather: hot and humid. Met briefly with John Orwig, lease operator, who was finishing up as I arrived. At the time of my inspection, there were 2 wells in production and 3 top-holed wells. Gravel that filled the cellars of these top-holed wells was being removed during my previous inspection of 07/27/16. The purpose of this inspection was to evaluate the annular vents that were uncovered after the cellars were vacc’ed out. An Altair 5X gas meter (calibrated on July 26) was used to monitor annular vents were monitored for combustible gas.

Myers Unit 7H: well in production: Tubing pressure: 500 psi (digital) 13-3/8” x 9-5/8”: no combustible gas detected 9-5/8” x 5-1/2”: no combustible gas detected No violations were noted at this time. Left location @ 09:40.

2509350 Primary Facility 2016-08-08 Follow-up Inspection No Violations Noted Arrived @ 10:30. Weather: hot. Met with Bird Smith, to follow up on my 7/29/16 inspection (IR# 2509164). For the three top-holed wells, he identifies the annular vent on the east side of the well as the 20” x 13-3/8”. The vent on the west side was for the 13-3/8” x 9-5/8” annulus. These vents were monitored for combustible gas using an Altair 5X gas meter (calibrated on August 8). The producing wells, Myers Unit 1H and Unit 7H, were also monitored.

Myers Unit 1H: well in production: Tubing pressure: 456 psi (digital) 13-3/8” x 9-5/8”: no combustible gas detected 9-5/8” x 5-1/2”: no combustible gas detected No violations were noted at this time. Left location @ 11:15.

2509651 Primary Facility 2016-08-08 Follow-up Inspection No Violations Noted Arrived @ 10:30. Weather: hot. Met with Bird Smith, to follow up on my 7/29/16 inspection (IR# 2509299). For the three top-holed wells, he identified the annular vent on the east side of the well as the 20” x 13-3/8”. The vent on the west side was for the 13-3/8” x 9-5/8” annulus. These vents were monitored for combustible gas using an Altair 5X gas meter (calibrated on August 8). The producing wells, Myers Unit 1H and Unit 7H, were also monitored.

Myers Unit 7H: well in production: Tubing pressure: 504psi (digital) 13-3/8” x 9-5/8”: no combustible gas detected 9-5/8” x 5-1/2”: no combustible gas detected No violations were noted at this time. Left location @ 11:15.

2534256 Primary Facility 2016-11-02 Follow-up Inspection No Violations Noted Arrived @ 8:45. Weather: foggy, warm. There were no personnel on site at the time of my inspection. There was a total of 5 wells on site: three top-holed wells: Myers Unit 2H, 3H, and 6H, and 2 wells capable of production, Myers Unit 1H & 7H. The producing wells were off-line at the time of my inspection. Annular vents on the 5 wells were monitored for combustible gas using an Altair gas meter (calibrated 11/2/16).

Myers Unit 7H: 20” x 13-3/8”: no combustible gas detected on either annulus. As I was leaving the site the lease operator was arriving to bring the producing wells back online. No violations for this well were noted at this time. Left location @ 9:15.

2564356 Primary Facility 2017-02-22 Follow-up Inspection No Violations Noted
2687841 Primary Facility 2018-01-26 Routine/Complete Inspection No Violations Noted Arrived @ 14:00. Weather: sunny, T¿s in 40¿s. There were no personnel on site at the time of my inspection. 5 wells were on site: three top-holed wells: Myers Unit 2H, 3H, 6H, and 2 wells in production, Myers Unit 1H & 7H. Annular vents on the Myers 6H and 2H were monitored for combustible gas using an Altair gas meter (calibrated 1/26/18).

Myers Unit 2H: 20¿ x 13-3/8¿: 0% combustible gas/volume; 13-3/8¿ x 9-5/8¿: 22% combustible gas/volume. Myers Unit 6H: 20¿ x 13-3/8¿: 0% combustible gas/volume; 13-3/8¿ x 9-5/8¿: 25% combustible gas/volume. Meyers 1H, in production. Discoloration and rust appear to be associated with a minor leak of produced water.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2058194 636542 04/02/2012 2012-04-02 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety hoses connecting trash pump to filter unit on bare pad, not containment. High conductivity puddles indicate there were leaks. Being fixed when I arrived.

For data sources see[8]

References