37-081-20786

Well Details

Well ID: 37-081-20786
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Penn Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 148937
Farm/Lease Name: MYERS UNIT 3H
License Status:
Spud Date:
Permit Date: 2011-12-08
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.298433
Longitude: -76.606267

For data sources see[1][2][3]

Well History

Date Event
2011-12-08 New Permit Application
2012-01-22 Performed Spud Operation

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 EXCO RESOURCES PA LLC Drilling Fluid Waste 6,270.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EXCO RESOURCES PA LLC Drill Cuttings 469.94 Tons LANDFILL 301358

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2058197 Primary Facility 2012-04-05 Routine/Partial Inspection No Violations Noted
2060845 Primary Facility 2012-04-19 Routine/Complete Inspection No Violations Noted
2062501 Primary Facility 2012-04-20 Routine/Complete Inspection No Violations Noted
2077327 Primary Facility 2012-06-14 Routine/Complete Inspection No Violations Noted
2086302 Primary Facility 2012-07-19 Routine/Complete Inspection No Violations Noted
2110551 Primary Facility 2012-10-24 Routine/Complete Inspection No Violations Noted
2117072 Primary Facility 2012-11-20 Routine/Complete Inspection No Violations Noted
2469543 Primary Facility 2016-03-25 Routine/Complete Inspection No Violations Noted At the time of the inspection, the Myers Unit 1H (081-20279) and 7H (081-20790 were in production. The well pad area was relatively well vegetated but some erosion of gravel off the well pad surface (photo attached) was noted. The well site has not been restored and the Well Site Compliance Information Request reply (submitted 9/21/2015) says the well site was permitted under an ESCGP-1 and a new drilling permit will be submitted in the fall of 2015. The Department has no record of an ESCGP issued for the site and no well permits have been issued for the site since 12/8/2011. The Department’s records indicate five active wells exist on the site, however, only the two wells mentioned above were located on the pad. The well pad remains at its original size. I recommend you apply for an ESCGP-2 to cover this since it has not been restored and was part of a larger disturbance. Please also provide an update on the status of the three active wells that were not found onsite.
2493129 Primary Facility 2016-06-09 Routine/Complete Inspection No Violations Noted Arrived @ 14:25. Weather sunny and warm. No company representatives were present at the time of the inspection.

This inspection was prompted by the receipt of Applications for Inactive Status for the Myers 2H, 3H, and 6H. These wells were topholed in 2012. At the time of my inspection, there were night caps on the three wells and the cellars were filled with gravel. There were no visible vent on the intermediate casing, nor were there any annular vents visible, so it was not possible to make an evaluation of casing pressures or cement integrity. I explained the situation to Brian Rushe, who agreed to make inquiries about it. There were also two completed wells on location the Myers 1H, which was shut-in, and Myers 7 H which was in production. No violations were apparent at the time of this inspection. Left location @ 15:00.

2505397 Primary Facility 2016-07-27 Routine/Complete Inspection No Violations Noted
2509263 Primary Facility 2016-07-29 Follow-up Inspection No Violations Noted Arrived @ 08:30. Weather: hot and humid. Met briefly with John Orwig, lease operator, who was finishing up as I arrived. At the time of my inspection, there were 2 wells in production and 3 top-holed wells. Gravel that filled the cellars of these top-holed wells was being removed during my previous inspection of 07/27/16. The purpose of this inspection was to evaluate the annular vents that were uncovered after the cellars were vacc’ed out. An Altair 5X gas meter (calibrated on July 26) was used to monitor annular vents were monitored for combustible gas.

Myers 3H: Top-holed well with 2 vents. At the time of my inspection the identity of these vents was unclear. Vent on the east side of the well: no combustible gas detected Vent on the west side of the well: no combustible gas detected. The result of this inspection is, “NOVIO” because no violations were identified . Left @ 09:40.

2509645 Primary Facility 2016-08-08 Follow-up Inspection No Violations Noted Arrived @ 10:30. Weather: hot. Met with Bird Smith, to follow up on my 7/29/16 inspection (IR2509263). For the three top-holed wells, Bird Smith identified the annular vent on the east side of the well as the 20” x 13-3/8”. The vent on the west side was identified as the 13-3/8” x 9-5/8” annulus. These vents were monitored for combustible gas using an Altair 5X gas meter (calibrated on 8/8/16).

20” x 13-3/8”: no combustible gas detected 13-3/8” x 9-5/8”: no combustible gas detected. The result of this inspection is, “NOVIO” because no violations were identified . Left @ 11:15

2534239 Primary Facility 2016-11-02 Routine/Complete Inspection No Violations Noted Arrived @ 8:45. Weather: foggy, warm. There were no personnel on site at the time of my inspection. There was a total of 5 wells on site: three top-holed wells: Myers Unit 2H, 3H, and 6H, and 2 wells capable of production, Myers Unit 1H & 7H. The producing wells were off-line at the time of my inspection. Annular vents on the 5 wells were monitored for combustible gas using an Altair gas meter (calibrated 11/2/16).

Myers Unit 3H: no combustible gas detected on either annulus. No violations associated with this well were noted at this time. Left location @ 9:15.

2564351 Primary Facility 2017-02-22 Follow-up Inspection No Violations Noted Arrived @ 11:45. Weather: cloudy, warm. There were no personnel on site at the time of my inspection. There was a total of 5 wells on site: three top-holed wells: Myers Unit 2H, 3H, and 6H, and 2 wells in production, Myers Unit 1H & 7H. Annular vents on the 5 wells were monitored for combustible gas using an Altair gas meter (calibrated 2/22/17).

Myers Unit 1H: in prod, top gauge 301 psi (dig), no combustible gas detected on either annulus. Myers Unit 2H: 20” x 13-3/8”: 0% combustible gas/volume; 13-3/8” x 9-5/8”: 20% combustible gas/volume. Myers Unit 3H: no combustible gas detected on either annulus. Myers Unit 6H: 20” x 13-3/8”: 0% combustible gas/volume; 13-3/8” x 9-5/8”: 50% combustible gas/volume. Myers Unit 7H: 20” x 13-3/8”: in prod, top gauge 359 psi (dig), no combustible gas detected on either annulus. Left location @ 9:15. For the 3H the result of this inspection is NOVIO.

2687838 Primary Facility 2018-01-26 Routine/Complete Inspection No Violations Noted Arrived @ 14:00. Weather: sunny, T¿s in 40¿s. There were no personnel on site at the time of my inspection. 5 wells were on site: three top-holed wells: Myers Unit 2H, 3H, 6H, and 2 wells in production, Myers Unit 1H & 7H. Annular vents on the Myers 6H and 2H were monitored for combustible gas using an Altair gas meter (calibrated 1/26/18).

Myers Unit 2H: 20¿ x 13-3/8¿: 0% combustible gas/volume; 13-3/8¿ x 9-5/8¿: 22% combustible gas/volume. Myers Unit 6H: 20¿ x 13-3/8¿: 0% combustible gas/volume; 13-3/8¿ x 9-5/8¿: 25% combustible gas/volume. Meyers 1H, in production. Discoloration and rust appear to be associated with a minor leak of produced water.

2799692 Primary Facility 2018-11-07 Routine/Complete Inspection No Violations Noted Two wells staged for production phase. Two water separators and one sand separator. No leaks detected from production equipment. No violations noted.

For data sources see[7]