If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20786 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.298433,"lon":-76.606267,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Penn Township | |
Operator Name: EXCO RESOURCES PA LLC | |
Well Pad ID: 148937 | |
Farm/Lease Name: MYERS UNIT 3H | |
License Status: | |
Spud Date: | |
Permit Date: 2011-12-08 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.298433 | |
Longitude: -76.606267 |
Date | Event |
---|---|
2011-12-08 | New Permit Application |
2012-01-22 | Performed Spud Operation |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2019 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | EXCO RESOURCES PA LLC | Drilling Fluid Waste | 6,270.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2012 | EXCO RESOURCES PA LLC | Drill Cuttings | 469.94 Tons | LANDFILL | 301358 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2058197 | Primary Facility | 2012-04-05 | Routine/Partial Inspection | No Violations Noted | |
2060845 | Primary Facility | 2012-04-19 | Routine/Complete Inspection | No Violations Noted | |
2062501 | Primary Facility | 2012-04-20 | Routine/Complete Inspection | No Violations Noted | |
2077327 | Primary Facility | 2012-06-14 | Routine/Complete Inspection | No Violations Noted | |
2086302 | Primary Facility | 2012-07-19 | Routine/Complete Inspection | No Violations Noted | |
2110551 | Primary Facility | 2012-10-24 | Routine/Complete Inspection | No Violations Noted | |
2117072 | Primary Facility | 2012-11-20 | Routine/Complete Inspection | No Violations Noted | |
2469543 | Primary Facility | 2016-03-25 | Routine/Complete Inspection | No Violations Noted | At the time of the inspection, the Myers Unit 1H (081-20279) and 7H (081-20790 were in production. The well pad area was relatively well vegetated but some erosion of gravel off the well pad surface (photo attached) was noted. The well site has not been restored and the Well Site Compliance Information Request reply (submitted 9/21/2015) says the well site was permitted under an ESCGP-1 and a new drilling permit will be submitted in the fall of 2015. The Department has no record of an ESCGP issued for the site and no well permits have been issued for the site since 12/8/2011. The Department’s records indicate five active wells exist on the site, however, only the two wells mentioned above were located on the pad. The well pad remains at its original size. I recommend you apply for an ESCGP-2 to cover this since it has not been restored and was part of a larger disturbance. Please also provide an update on the status of the three active wells that were not found onsite. |
2493129 | Primary Facility | 2016-06-09 | Routine/Complete Inspection | No Violations Noted | Arrived @ 14:25. Weather sunny and warm. No company representatives were present at the time of the inspection.
This inspection was prompted by the receipt of Applications for Inactive Status for the Myers 2H, 3H, and 6H. These wells were topholed in 2012. At the time of my inspection, there were night caps on the three wells and the cellars were filled with gravel. There were no visible vent on the intermediate casing, nor were there any annular vents visible, so it was not possible to make an evaluation of casing pressures or cement integrity. I explained the situation to Brian Rushe, who agreed to make inquiries about it. There were also two completed wells on location the Myers 1H, which was shut-in, and Myers 7 H which was in production. No violations were apparent at the time of this inspection. Left location @ 15:00. |
2505397 | Primary Facility | 2016-07-27 | Routine/Complete Inspection | No Violations Noted | |
2509263 | Primary Facility | 2016-07-29 | Follow-up Inspection | No Violations Noted | Arrived @ 08:30. Weather: hot and humid. Met briefly with John Orwig, lease operator, who was finishing up as I arrived. At the time of my inspection, there were 2 wells in production and 3 top-holed wells. Gravel that filled the cellars of these top-holed wells was being removed during my previous inspection of 07/27/16. The purpose of this inspection was to evaluate the annular vents that were uncovered after the cellars were vacc’ed out. An Altair 5X gas meter (calibrated on July 26) was used to monitor annular vents were monitored for combustible gas.
Myers 3H: Top-holed well with 2 vents. At the time of my inspection the identity of these vents was unclear. Vent on the east side of the well: no combustible gas detected Vent on the west side of the well: no combustible gas detected. The result of this inspection is, “NOVIO” because no violations were identified . Left @ 09:40. |
2509645 | Primary Facility | 2016-08-08 | Follow-up Inspection | No Violations Noted | Arrived @ 10:30. Weather: hot. Met with Bird Smith, to follow up on my 7/29/16 inspection (IR2509263). For the three top-holed wells, Bird Smith identified the annular vent on the east side of the well as the 20” x 13-3/8”. The vent on the west side was identified as the 13-3/8” x 9-5/8” annulus. These vents were monitored for combustible gas using an Altair 5X gas meter (calibrated on 8/8/16).
20” x 13-3/8”: no combustible gas detected 13-3/8” x 9-5/8”: no combustible gas detected. The result of this inspection is, “NOVIO” because no violations were identified . Left @ 11:15 |
2534239 | Primary Facility | 2016-11-02 | Routine/Complete Inspection | No Violations Noted | Arrived @ 8:45. Weather: foggy, warm. There were no personnel on site at the time of my inspection. There was a total of 5 wells on site: three top-holed wells: Myers Unit 2H, 3H, and 6H, and 2 wells capable of production, Myers Unit 1H & 7H. The producing wells were off-line at the time of my inspection. Annular vents on the 5 wells were monitored for combustible gas using an Altair gas meter (calibrated 11/2/16).
Myers Unit 3H: no combustible gas detected on either annulus. No violations associated with this well were noted at this time. Left location @ 9:15. |
2564351 | Primary Facility | 2017-02-22 | Follow-up Inspection | No Violations Noted | Arrived @ 11:45. Weather: cloudy, warm. There were no personnel on site at the time of my inspection. There was a total of 5 wells on site: three top-holed wells: Myers Unit 2H, 3H, and 6H, and 2 wells in production, Myers Unit 1H & 7H. Annular vents on the 5 wells were monitored for combustible gas using an Altair gas meter (calibrated 2/22/17).
Myers Unit 1H: in prod, top gauge 301 psi (dig), no combustible gas detected on either annulus. Myers Unit 2H: 20” x 13-3/8”: 0% combustible gas/volume; 13-3/8” x 9-5/8”: 20% combustible gas/volume. Myers Unit 3H: no combustible gas detected on either annulus. Myers Unit 6H: 20” x 13-3/8”: 0% combustible gas/volume; 13-3/8” x 9-5/8”: 50% combustible gas/volume. Myers Unit 7H: 20” x 13-3/8”: in prod, top gauge 359 psi (dig), no combustible gas detected on either annulus. Left location @ 9:15. For the 3H the result of this inspection is NOVIO. |
2687838 | Primary Facility | 2018-01-26 | Routine/Complete Inspection | No Violations Noted | Arrived @ 14:00. Weather: sunny, T¿s in 40¿s. There were no personnel on site at the time of my inspection. 5 wells were on site: three top-holed wells: Myers Unit 2H, 3H, 6H, and 2 wells in production, Myers Unit 1H & 7H. Annular vents on the Myers 6H and 2H were monitored for combustible gas using an Altair gas meter (calibrated 1/26/18).
Myers Unit 2H: 20¿ x 13-3/8¿: 0% combustible gas/volume; 13-3/8¿ x 9-5/8¿: 22% combustible gas/volume. Myers Unit 6H: 20¿ x 13-3/8¿: 0% combustible gas/volume; 13-3/8¿ x 9-5/8¿: 25% combustible gas/volume. Meyers 1H, in production. Discoloration and rust appear to be associated with a minor leak of produced water. |
2799692 | Primary Facility | 2018-11-07 | Routine/Complete Inspection | No Violations Noted | Two wells staged for production phase. Two water separators and one sand separator. No leaks detected from production equipment. No violations noted. |
For data sources see[7]