If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20767 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.259469,"lon":-76.565942,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Franklin Township | |
Operator Name: XTO ENERGY INC | |
Well Pad ID: 147869 | |
Farm/Lease Name: BUCK UNIT A 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2011-12-14 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.259469 | |
Longitude: -76.565942 |
Date | Event |
---|---|
2011-12-14 | New Permit Application |
2012-07-16 | Performed Spud Operation |
2012-08-19 | Drilling Completion |
2012-09-12 | Perforation |
2013-06-10 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-09-19 | 2012-09-19 | 7,676 | 5,947,494 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Friction Reducer - MC MX-14-5 | Multi-Chem Group | Friction Reducer | Whole Product | ||||
Other -(non hazardous) | 70.00 | 0.03 | ||||||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.01 | |||||
Biocide - MC 8650 | Multi-Chem Group | Biocide | Whole Product | |||||
Other -(non hazardous) | 40.00 | 0.00263000 | ||||||
Glutaraldehyde | 111-30-8 | 60.00 | 0.00395000 | |||||
Acid - 7.5 HCl Acid | PPG Industries | Acid | Other -(non hazardous) | 92.50 | 0.41 | |||
Hydrochloric acid | 7647-01-0 | 7.50 | 0.03 | |||||
Whole Product | ||||||||
Acid Corrosion Inhibitor - EcoAcid CI | Geosafe Chemicals | Corrosion Inhibitor | Diethylene glycol monobutyl ether | 112-34-5 | 50.00 | 0.00019000 | ||
Whole Product | ||||||||
Other -(non hazardous) | 50.00 | 0.00019000 | ||||||
Water | Water | 7732-18-5 | 100.00 | 87.40 | ||||
Scale Inhibitor - MC-MX-588-2 | Multi-Chem Group | Scale Inhibitor | Other -(non hazardous) | 100.00 | 0.02 | |||
Whole Product | ||||||||
Sand | Proppant | Quartz | 14808-60-7 | 100.00 | 12.04 | |||
Biocide - MC 8520 | Multi-Chem Group | Biocide | 3,4,4-Trimethyloxazolidine | 75673-43-7 | 4.50 | 0.00066000 | ||
4,4-Dimethyloxazolidine | 51200-87-4 | 95.00 | 0.01 | |||||
2-Amino-2-methylpropan-1-ol | 124-68-5 | 0.50 | 0.00007000 | |||||
Whole Product |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | XTO ENERGY INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | XTO ENERGY INC | 74,897.00 | 98 | 0.00 | 0 | 0.00 | 0 |
2013 | XTO ENERGY INC | 624,075.00 | 359 | 0.00 | 0 | 0.00 | 0 |
2014 | XTO ENERGY INC | 614,561.00 | 362 | 0.00 | 0 | 0.00 | 0 |
2015 | XTO ENERGY INC | 514,392.00 | 324 | 0.00 | 0 | 0.00 | 0 |
2016 | XTO ENERGY INC | 507,140.00 | 352 | 0.00 | 0 | 0.00 | 0 |
2017 | XTO ENERGY INC | 453,894.00 | 340 | 0.00 | 0 | 0.00 | 0 |
2018 | XTO ENERGY INC | 357,326.07 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | XTO ENERGY INC | 319,703.85 | 364 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | XTO ENERGY INC | Produced Fluid | 106.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2012 | XTO ENERGY INC | Produced Fluid | 309.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012 | XTO ENERGY INC | Fracing Fluid Waste | 511.00 Bbl | INJECTION DISPOSAL WELL | 34-133-21076 |
2012 | XTO ENERGY INC | Fracing Fluid Waste | 2,087.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012 | XTO ENERGY INC | Drill Cuttings | 1,332.77 Tons | LANDFILL | 301626 |
2012 | XTO ENERGY INC | Produced Fluid | 427.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2012 | XTO ENERGY INC | Fracing Fluid Waste | 1,085.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2012 | XTO ENERGY INC | Produced Fluid | 91.00 Bbl | INJECTION DISPOSAL WELL | 34-133-21076 |
2013 | XTO ENERGY INC | Produced Fluid | 323.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013 | XTO ENERGY INC | Produced Fluid | 207.00 Bbl | INJECTION DISPOSAL WELL | 34-133-21076 |
2013 | XTO ENERGY INC | Produced Fluid | 630.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2013 | XTO ENERGY INC | Produced Fluid | 214.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2013 | XTO ENERGY INC | Produced Fluid | 320.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013 | XTO ENERGY INC | Produced Fluid | 597.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2014 | XTO ENERGY INC | Produced Fluid | 300.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | XTO ENERGY INC | Produced Fluid | 98.24 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | XTO ENERGY INC | Produced Fluid | 200.29 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | XTO ENERGY INC | Produced Fluid | 181.84 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | XTO ENERGY INC | Produced Fluid | 112.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | XTO ENERGY INC | Produced Fluid | 105.64 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2016 | XTO ENERGY INC | Produced Fluid | 108.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2016 | XTO ENERGY INC | Produced Fluid | 112.17 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | XTO ENERGY INC | Produced Fluid | 203.29 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | XTO ENERGY INC | Produced Fluid | 98.79 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | XTO ENERGY INC | Produced Fluid | 114.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | XTO ENERGY INC | Produced Fluid | 113.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24189 |
2018 | XTO ENERGY INC | Produced Fluid | 50.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | XTO ENERGY INC | Produced Fluid | 119.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
2019 | XTO ENERGY INC | Produced Fluid | 90.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2060393 | Primary Facility | 2012-04-17 | Routine/Complete Inspection | No Violations Noted | |
2081374 | Primary Facility | 2012-07-05 | Routine/Complete Inspection | No Violations Noted | |
2084204 | Primary Facility | 2012-07-18 | Drilling/Alteration | No Violations Noted | |
2089882 | Primary Facility | 2012-08-06 | Drilling/Alteration | No Violations Noted | |
2093723 | Primary Facility | 2012-08-22 | Drilling/Alteration | No Violations Noted | |
2098562 | Primary Facility | 2012-09-05 | Routine/Complete Inspection | No Violations Noted | |
2098705 | Primary Facility | 2012-09-11 | Routine/Partial Inspection | No Violations Noted | |
2101825 | Primary Facility | 2012-09-14 | Drilling/Alteration | Violation(s) Noted | |
2110578 | Primary Facility | 2012-10-24 | Routine/Complete Inspection | No Violations Noted | |
2123256 | Primary Facility | 2012-12-07 | Routine/Complete Inspection | No Violations Noted | |
2124757 | Primary Facility | 2012-12-18 | Routine/Complete Inspection | No Violations Noted | |
2149640 | Primary Facility | 2013-03-20 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | |
2289039 | Primary Facility | 2014-07-14 | Routine/Complete Inspection | No Violations Noted | The PCSM plan indicates stormwater rate/volume reduction based on infiltration into the infiltration basins. The infiltration basins clearly do not infiltrate well and do not dewater within 72 hours. Erosion is still visible in the channels leading into the basins. This sediment is obviously a contributor to the reduced infiltration rate. In addition, the south/southeast side cut-slope has not achieved 70% vegetative cover. This site does not meet the PCSM criteria outlined in the approved plans and requires corrective action. Please correct the erosion in the channel leading to the infiltration basins ASAP. |
2514930 | Primary Facility | 2016-08-24 | Site Restoration | No Violations Noted | Notice of Termination/Well Site Restoration Report Inspection; 8/24/2016.
I entered the site at 14:11 to find one well in production. The PCSM (Post Construction Stormwater Management) plan calls for the rock-lined ditch on the cut side of the well pad to be converted into an infiltration trench yet the current trench is filled with rock and has the same erosion control blanketing originally used for stabilization. In addition, the calculations describe the infiltration basins a being empty after rain events. The basins currently onsite do not dewater and appear to have limited infiltration capacity. I recommend implementing the infiltration trench as designed and re-evaluating the infiltration basins. In addition, the slopes above the infiltration basins are not permanently stabilized. I recommend denying both the Notice of Termination the Well Site Restoration Report. No Violations Noted. |
2815636 | Primary Facility | 2018-12-14 | Routine/Complete Inspection | No Violations Noted | One steel production tank and one GPU within plastic lined steel containment. No corrosion noted. No leaks observed.
The PCSM (Post Construction Stormwater Management) plan has established a infiltration trench on the fill side of the well pad. |
2841887 | Primary Facility | 2019-02-05 | Routine/Complete Inspection | No Violations Noted | XTO Energy Inc. has submitted a notice of termination (NOT) to the Department for Buck Unit A covered under ESX110810076(01). The Department received the NOT on January 07, 2019.
Department representative Jared Jacobini conducted a restoration site inspection at the above listed site on February 5, 2019. The site sign, emergency response plan, and ESCGP were onsite for review. The Infiltration detail does not show or describe corrugated pipe (Photo 8) present inline with underdrain on the downstream side of embankments in the infiltration basin. The department recommends the following: Add riprap to Infiltration Basin #2 (Photo #15) due to a large amount of flowing water causing erosion in the area that PC4 enters the basin. Fill and seed in the area of tire ruts (Photo #13-14). Fill and seed settling areas at each basin (Photo #10, 12). Determine if the infiltration basin is functioning (Photo #11). Monitor PC4&PC5for erosion (Photo #2, 16). Removing construction materials present in Infiltration Trench |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2101825 | 649820 | 09/14/2012 | 2012-09-14 | 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | Administrative | 8% methane fornd outside of the surface casing. The other 2 inner annuli are also leaking. |
2101825 | 653014 | 09/14/2012 | 2012-09-14 | 78.73A - Operator shall prevent gas and other fluids from lower formations from entering fresh groundwater. | Environmental Health & Safety | gas outside surface casing, correct reg citation 78.73(b) |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
649820 | 290328 | NOV - Notice of Violation | |||||
653014 | 290328 | NOV - Notice of Violation |
For data sources see[8]