Well Details

Well ID: 37-081-20586
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: McIntyre Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 147013
Farm/Lease Name: DCNR 100 85V 50501
License Status: PLUGGED & ABANDONED
Spud Date:
Permit Date: 2011-05-16
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 41.466678
Longitude: -77.056961

For data sources see[1][2][3]

Well History

Date Event
2011-05-16 New Permit Application
2011-06-25 Performed Spud Operation
2011-07-27 Drilling Completion
2012-03-08 NEWLY DRILLED
2013-11-07 Drilling Completion
2014-12-03 FULLY PLUGGED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2012 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2013 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2014 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 SENECA RESOURCES CO LLC Drill Cuttings 360.67 Tons LANDFILL 100955

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1989141 Primary Facility 2011-07-21 Drilling/Alteration No Violations Noted
2013925 Primary Facility 2011-10-25 Routine/Complete Inspection No Violations Noted
2032371 Primary Facility 2012-01-05 Routine/Complete Inspection No Violations Noted
2034885 Primary Facility 2012-01-11 Routine/Complete Inspection Violation(s) Noted
2061052 Primary Facility 2012-04-11 Routine/Complete Inspection No Violations Noted getting ready to flare and flow-back. site looks good, containment looks good.
2089836 Primary Facility 2012-08-06 Drilling/Alteration Outstanding Violations - No Viols Req'd
2109862 Primary Facility 2012-10-23 Routine/Complete Inspection No Violations Noted
2288786 Primary Facility 2014-07-22 Plugging(Includes Plugged/Mined Through) No Violations Noted
2481998 Primary Facility 2016-05-03 Routine/Complete Inspection No Violations Noted Plugged well with candy cane surrounded by concrete barriers. No gas detected at vent.
2487616 Primary Facility 2016-05-17 Routine/Complete Inspection No Violations Noted Routine Inspection; 5/17/2016.

I entered the location at 08:31 and began the inspection. At the time of the inspection, the DCNR 100 85V (081-20586) well was plugged on 11/7/2013 and the monument was visible at the surface surrounded by concrete barriers. The well pad area contains stockpiled fill and also pipeline infrastructure which is not covered under ESX11-081-0097. The well site remains at its originally constructed size and has not been restored according to the PCSM (Post Construction Stormwater Management) plan in the ESCGP. The current ESCGP expires on 5/30/2016. The restoration assessment spreadsheet indicates the Notice of Termination and Well Site Restoration Report as pending. Please note this ESCGP also covers an impoundment adjacent to the Hagerman Run Compressor Station and road upgrades between the two.

The Department considers a well site to be restored under Section 3216(c) of the 2012 Oil and Gas Act when the oil or gas owners or operators meet the following:

1. All permane
2527472 Primary Facility 2016-10-13 Plugging(Includes Plugged/Mined Through) No Violations Noted On October 13, 2016 at 10:45 am I conducted a routine inspection of Seneca’s DCNR 100 85V 50501 Plugged gas well in McIntryre Twp. Lycoming County. The well was drilled in 2011, plugged in 2013 (see well records and plugging certificate for details). A 2” candycane vent remains on the pad w/well tag “DATE PLUGGED 11/06/13”. I used an Altair 5x gas meter to check for gas at the vent; no gas. No issues found.
2645603 Primary Facility 2017-09-27 Routine/Complete Inspection No Violations Noted The monument for the plugged well (081-20586) was visible inside concrete barricades. The site is being used for parking and general storage. Recent earth disturbance was noticeable but is covered by ESX11-081-0097(04) issued to National Fuel Gas for an overlapping valve site. ESX11-081-0033 covers this well site and depicts the site restored back to approximate original contours and a line of trees planted adjacent to the road. The ESCGP is expired and the current condition of the site dies not meet the restoration plans. I recommend re-permitting the site to reflect the planned conditions onsite. I recommend denying the Well Site Restoration Report. No violations noted.
2658780 Primary Facility 2017-11-09 Administrative/File Review No Violations Noted On 9/27/2017, I conducted an inspection of the site and denied the Well Site Restoration Report for this site. Please see inspection record # 2645603. I again recommend denying the Well Site Restoration Report since the site was not restored according to ESX11-081-0033. The ESCGP is currently expired. I recommend re-permitting the site with and ESCGP and implementing the plans. No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2034885 629507 01/11/2012 2012-01-11 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days Administrative gas found and the presence of methane in the annular space of the 7" x 4 1/2" casing,