If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20268 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.445776,"lon":-77.010853,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Lewis Township | |
Operator Name: SENECA RESOURCES CO LLC | |
Well Pad ID: 150570 | |
Farm/Lease Name: DCNR 100 5H 50032 | |
License Status: | |
Spud Date: | |
Permit Date: 2010-03-30 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.445776 | |
Longitude: -77.010853 |
Date | Event |
---|---|
2010-03-30 | New Permit Application |
2010-05-07 | Performed Spud Operation |
2010-07-07 | Drilling Completion |
2010-08-27 | Perforation |
2010-10-20 | DEVIATED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SENECA RESOURCES CO LLC | 2,101,377.00 | 348 | 0.00 | 0 | 0.00 | 0 |
2014 | SENECA RESOURCES CO LLC | 1,177,344.60 | 355 | 0.00 | 0 | 0.00 | 0 |
2015 | SENECA RESOURCES CO LLC | 181,281.19 | 68 | 0.00 | 0 | 0.00 | 0 |
2016 | SENECA RESOURCES CO LLC | 903,525.52 | 316 | 0.00 | 0 | 0.00 | 0 |
2017 | SENECA RESOURCES CO LLC | 601,622.08 | 362 | 0.00 | 0 | 0.00 | 0 |
2018 | SENECA RESOURCES CO LLC | 439,030.80 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | SENECA RESOURCES CO LLC | 313,570.98 | 343 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | SENECA RESOURCES CO LLC | Fracing Fluid Waste | 9,064.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2010 | SENECA RESOURCES CO LLC | Drill Cuttings | 649.15 Tons | LANDFILL | 100955 |
2013 | SENECA RESOURCES CO LLC | Produced Fluid | 7,325.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SENECA RESOURCES CO LLC | Produced Fluid | 18.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC012 |
2013 | SENECA RESOURCES CO LLC | Drill Cuttings | 42.79 Tons | LANDFILL | 301358 |
2013 | SENECA RESOURCES CO LLC | Produced Fluid | 176.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC012 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 9.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC012 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 20.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 1,153.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 72.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 26.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 208.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 127.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 1,522.20 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 83.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 1,461.75 Bbl | REUSE (AT WELL PAD) | |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 854.57 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 782.86 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 502.43 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 129.28 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 222.14 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Synthetic Liner Materials | 0.10 Tons | LANDFILL | 301358 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 147.64 Bbl | RESIDUAL WASTE TRANSFER FACILITY | WMGR123NC039 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 25.55 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2019 | SENECA RESOURCES CO LLC | Synthetic Liner Materials | 6.38 Tons | LANDFILL | 301358 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 96.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 75.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 373.75 Bbl | REUSE (AT WELL PAD) | |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 272.54 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC003 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 780.74 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Waste Water Treatment Sludge | 9.16 Tons | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 76.98 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 30.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC003 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 573.39 Bbl | REUSE (AT WELL PAD) | |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 251.11 Bbl | RESIDUAL WASTE TRANSFER FACILITY | WMGR123NC039 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1876564 | Primary Facility | 2010-04-12 | Routine/Complete Inspection | Violation(s) Noted | |
1885403 | Primary Facility | 2010-05-18 | Compliance Evaluation | Viol(s) Noted & Immediately Corrected | |
1891007 | Primary Facility | 2010-05-24 | Drilling/Alteration | No Violations Noted | hwd rig 4 drilling rig @ 265 ft deep,,,, ran 100 ft 24" conductor |
1900709 | Primary Facility | 2010-07-26 | Routine/Partial Inspection | Violation(s) Noted | Cement returns and drill cuttings on the ground |
1901570 | Primary Facility | 2010-07-29 | Compliance Evaluation | No Violations Noted | |
1902283 | Primary Facility | 2010-07-20 | Drilling/Alteration | No Violations Noted | |
1902294 | Primary Facility | 2010-06-23 | Drilling/Alteration | No Violations Noted | |
2000115 | Primary Facility | 2011-09-01 | Routine/Complete Inspection | No Violations Noted | |
2000238 | Primary Facility | 2011-09-02 | Routine/Complete Inspection | No Violations Noted | |
2002960 | Primary Facility | 2011-09-13 | Routine/Complete Inspection | No Violations Noted | |
2032370 | Primary Facility | 2012-01-05 | Routine/Complete Inspection | No Violations Noted | |
2061064 | Primary Facility | 2012-04-11 | Routine/Complete Inspection | No Violations Noted | Rig on the M-pad drilling the 7H top-hole section, getting ready to switch to mud and go back through |
2061609 | Primary Facility | 2012-04-20 | Drilling/Alteration | No Violations Noted | |
2069494 | Primary Facility | 2012-05-15 | Incident- Response to Accident or Event | No Violations Noted | |
2089817 | Primary Facility | 2012-08-06 | Drilling/Alteration | No Violations Noted | |
2098583 | Primary Facility | 2012-09-06 | Routine/Complete Inspection | No Violations Noted | |
2105919 | Primary Facility | 2012-10-04 | Routine/Partial Inspection | No Violations Noted | |
2128889 | Primary Facility | 2013-01-09 | Routine/Complete Inspection | No Violations Noted | |
2150544 | Primary Facility | 2013-03-22 | Routine/Complete Inspection | No Violations Noted | |
2173410 | Primary Facility | 2013-05-31 | Routine/Complete Inspection | No Violations Noted | |
2487620 | Primary Facility | 2016-05-17 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 5/17/2016.
I entered the DCNR Tract 100 M pad at 09:17 and began the inspection. At the time of the inspection, the DCNR 100 3H (081-20853), 5H (081-20268), 6H (081-20854), 7H (081-20855), 8H (081-20856), 9H (081-20857), and 66H (081-20975) wells were in production. The well site has been expanded so that the impoundment area originally permitted in the ESCGP has been reclaimed and replaced with impervious well pad area. The site has not been restored according to the PCSM (Post Construction Stormwater Management) plan in the ESCGP which does not include the expanded well pad area. Well cellars have been constructed on the expanded well pad area but each of the wells that were permitted for this expanded pad area is classified as “Operator Reported Not Drilled.” The current ESCGP expired on 1/10/2015. The restoration assessment spreadsheet indicates the Notice of Termination and Well Site Restoration Report as pending and a return trip is planned. The most recent well permits iss |
2800571 | Primary Facility | 2018-11-08 | Routine/Complete Inspection | No Violations Noted | Weather was 39° and sunny at time of inspection. There were no Seneca Resources representatives on location at time of inspection. Well had digital pressure monitoring equipment on the production tubing and the production casing. Tubing pressure was 168 psi and casing pressure was 240 psi at time of inspection. Well had 3 annulus vent plumbed to surface that we labeled clearly. 0% combustible gas was detected on the annulus vents at time of inspection. No violations were noted at time of inspection. |
2805159 | Primary Facility | 2018-11-20 | Routine/Complete Inspection | No Violations Noted | Seven wells staged for production phase. Seven each water separators. No leaks detected from production equipment. Methanol tank located near well heads. No violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1876564 | 585065 | 04/12/2010 | 2010-04-12 | 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling | Administrative | |
1885403 | 587302 | 05/18/2010 | 2010-05-18 | 301CSL - Stream discharge of IW, includes drill cuttings, oil, brine and/or silt | Environmental Health & Safety | Hole punctured in tanker allowed drilling mud to leak/splash out onto access road. Mud was cleaned up and underneath soil excavated within an hour. |
1900709 | 591807 | 07/26/2010 | 2010-07-26 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | 78.56(a)(4) |
1900709 | 591808 | 07/26/2010 | 2010-07-26 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
1900709 | 591809 | 07/26/2010 | 2010-07-26 | 51017 - Administrative Code-General | Administrative | 35 PS 6018.301 |
For data sources see[7]