X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-065-26972

Well Details

Well ID: 37-065-26972
Loading map...
Country: United States
State: Pennsylvania
County: Jefferson
Municipality: McCalmont Township
Operator Name: XTO ENERGY INC
Well Pad ID: 149124
Farm/Lease Name: R C WINSLOW 1H
License Status:
Spud Date: 2012-02-04
Permit Date: 2011-10-11
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.040583
Longitude: -78.991794

For data sources see[1][2][3]

Well History

Date Event
2011-10-11 New Permit Application
2012-01-09 Performed Spud Operation
2012-02-23 Drilling Completion
2012-04-10 Perforation
2012-06-13 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-04-14 2012-04-14 7,159 5,302,920

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Biocide - MC 8650 Multi-Chem Group Biocide Onter-(non Hazardous) 40.00 0.00307000
Whole Product
Glutaraldehyde 111-30-8 60.00 0.00461000
Acid - 7.5 HCL Acid Universal Well Services Acid Whole Product
Hydrogen Chloride (31-33) blended dow to 7.5 7.50 0.02
Other - (non Hazardous) 92.50 0.30
Scale Inhibitor - MC-MX-588-2 Multi-Chem Group Scale Inhibitor Whole Product
Onter-(non Hazardous) 100.00 0.01
Acid Inhibitor Universal Well Services Corrosion Inhibitor Proprietary Blend Surfactant 25.00 0.00008000
Short Chained Glycol Ether 50.00 0.00016000
Ethoxylated Alcohol 25.00 0.00008000
Diethylene glycol monobutyl ether 112-34-5
Sand Proppant Quartz 14808-60-7 100.00 11.13
Biocide - MC 8520 Multi-Chem Group Biocide 2-Amino-2-methylpropan-1-ol 124-68-5 0.50 0.00009000
3,4,4-Trimethyloxazolidine 75673-43-7 4.50 0.00078000
4,4-Dimethyloxazolidine 51200-87-4 95.00 0.01
Whole Product
Water Water 7732-18-5 100.00 88.39
Friction Reducer-MC MX 14-5 Multi-Chem Group Friction Reducer Hydrotreated Light Distillates (10-30) 30.00 0.02
Whole Product
Other- (non hazardous) 70.00 0.06

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2012 XTO ENERGY INC 6,081.00 179 0.00 0 0.00 0
2013 XTO ENERGY INC 19,270.00 271 0.00 0 0.00 0
2014 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2015 XTO ENERGY INC 271,495.00 185 0.00 0 0.00 0
2016 XTO ENERGY INC 315,733.00 366 0.00 0 0.00 0
2017 XTO ENERGY INC 196,442.00 247 0.00 0 0.00 0
2018 XTO ENERGY INC 211,864.64 288 0.00 0 0.00 0
2019 XTO ENERGY INC 171,463.90 359 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 XTO ENERGY INC Drill Cuttings 304.53 Tons LANDFILL 100434
2012 XTO ENERGY INC Drill Cuttings 1,154.33 Tons LANDFILL 101397
2013 XTO ENERGY INC Produced Fluid 198.00 Bbl RESIDUAL WASTE TRANSFER FACILITY 101674
2015 XTO ENERGY INC Produced Fluid 972.40 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 XTO ENERGY INC Produced Fluid 2,383.40 Bbl INJECTION DISPOSAL WELL 34-133-24096
2015 XTO ENERGY INC Produced Fluid 1,085.10 Bbl INJECTION DISPOSAL WELL 34-133-21076
2015 XTO ENERGY INC Produced Fluid 10,305.70 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2016 XTO ENERGY INC Produced Fluid 200.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 XTO ENERGY INC Produced Fluid 65.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 XTO ENERGY INC Produced Fluid 90.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2016 XTO ENERGY INC Produced Fluid 390.00 Bbl INJECTION DISPOSAL WELL 34-133-21076
2016 XTO ENERGY INC Produced Fluid 575.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 XTO ENERGY INC Produced Fluid 7,299.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2016 XTO ENERGY INC Produced Fluid 5,819.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2016 XTO ENERGY INC Produced Fluid 204.00 Bbl INJECTION DISPOSAL WELL 34-133-24189
2017 XTO ENERGY INC Produced Fluid 8,937.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2017 XTO ENERGY INC Produced Fluid 100.00 Bbl REUSE (AT WELL PAD)
2018 XTO ENERGY INC Produced Fluid 100.10 Bbl REUSE (AT WELL PAD)
2018 XTO ENERGY INC Produced Fluid 119.70 Bbl INJECTION DISPOSAL WELL 34-133-24189
2018 XTO ENERGY INC Produced Fluid 6,590.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 XTO ENERGY INC Produced Fluid 3,757.30 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 XTO ENERGY INC Produced Fluid 316.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2019 XTO ENERGY INC Produced Fluid 577.00 Bbl REUSE (AT WELL PAD)
2019 XTO ENERGY INC Produced Fluid 747.38 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 XTO ENERGY INC Produced Fluid 792.10 Bbl INJECTION DISPOSAL WELL 34-133-24189
2019 XTO ENERGY INC Produced Fluid 860.34 Bbl INJECTION DISPOSAL WELL 34-133-21076

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2033894 Primary Facility 2012-01-12 Routine/Complete Inspection No Violations Noted
2035663 Primary Facility 2012-01-19 Drilling/Alteration No Violations Noted
2041179 Primary Facility 2012-02-08 Drilling/Alteration Violation(s) Noted
2044649 Primary Facility 2012-02-17 Drilling/Alteration No Violations Noted
2049730 Primary Facility 2012-03-02 Drilling/Alteration No Violations Noted
2055709 Primary Facility 2012-04-02 Routine/Complete Inspection No Violations Noted
2107024 Primary Facility 2012-10-10 Compliance Evaluation No Violations Noted
2174972 Primary Facility 2013-06-11 Routine/Complete Inspection No Violations Noted
2318584 Primary Facility 2014-11-03 Routine/Partial Inspection No Violations Noted
2355751 Primary Facility 2015-03-26 Routine/Complete Inspection No Violations Noted
2398802 Primary Facility 2015-08-13 Routine/Complete Inspection No Violations Noted
2584513 Primary Facility 2017-04-13 Routine/Complete Inspection No Violations Noted This well has been completed in a forested area off of Knoxdale Road. The spud date for this well was 1/9/2012, and drilling was completed on 2/22/2012. The ESCGP that covers this site is ESX11-065-0037. Two other wells on this pad have also been completed (065-26992 - R.C. Winslow #2H, and 065-26993 - R.C. Winslow #3H), and all three are now in production and connected to the 10 mile Winslow pipeline. The well has been tagged with the correct DEP permit number. The access road and well pad have been stabilized with rock. The steep section of the access road has also been covered with tar & chip. The sections of mining belt that were installed to divert water from the road surface have been destroyed and should be replaced.

Vegetation has stabilized the steep slope of the original gas pipeline. Most areas of disturbed soil surrounding the site remains covered with either mulch or vegetation and appear stable. Some ditches have been disturbed during construction of the compressor that has been installed at

2601185 Primary Facility 2017-06-02 Routine/Partial Inspection No Violations Noted
2660045 Primary Facility 2017-11-14 Routine/Complete Inspection No Violations Noted Inspected location. Currently frac operations shut down. Xto crew picking litter along access road. Site looks good.
2685813 Primary Facility 2018-01-24 Routine/Partial Inspection No Violations Noted Currently setting up 2 new wells for flowback operations.
2726506 Primary Facility 2018-05-04 Routine/Partial Inspection No Violations Noted XTO personnel on site currently working on production unit bringing wells online. All production equipment is within containment. All wells are connected to the sales line. Dehydration unit and compressor on north side of location.

Flowback equipment onsite, but is disconnected. 2 disconnected 500 Bbl flow back tanks in containment on location. Wells are connected to sand separators that are connected to a 500 Bbl tank in containment.

2750492 Primary Facility 2018-07-11 Routine/Complete Inspection No Violations Noted This well has been completed in a forested area off of Knoxdale Road. The spud date for this well was 1/9/2012, and drilling was completed on 2/22/2012. The ESCGP that covers this site is ESX11-065-0037B. Four other wells on this pad have also been completed:

(065-26992 - R.C. Winslow # 2H, 065-26993 - R.C. Winslow 3H, 065-27079 - R.C. Winslow # 5H, and 065-27080 - R.C. Winslow # 6HU).

The access road and well pad had been stabilized with rock, but recent weather and traffic have caused erosion of the road surface. Stabilization should be monitored. No violations were noted during this inspection.

2771940 Primary Facility 2018-09-06 Routine/Partial Inspection No Violations Noted At the time of inspection, well appeared to be producing. The well integrity was in good condition, with no signs of any leaks or spills. The well was hooked up to a self contained unit with methanol in it. There were 2 of these units onsite. The well was labeled and the Emergency Response sign was posted at the site entrance.

Near the wells was a diffuser tank and 4 separator units. The diffuser tank was in high berm plastic containment. At the corner of the pad was a compressor station. Also, contained within a lined, steel dike were 6 steel tanks, 2 very large line heater / separator units, and 4 average size line heater / separator units.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2041179 631662 02/08/2012 2012-02-08 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative Failure to notify Department of cement not circulated to surface on surface casing
2041179 631663 02/08/2012 2012-02-08 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative Failure to have cement tickets on location for review by the Department

For data sources see[8]

References