Well Details

Well ID: 37-065-25046
Loading map...
Country: United States
State: Pennsylvania
County: Jefferson
Municipality: McCalmont Township
Operator Name: DANNIC ENERGY CORP
Well Pad ID:
Farm/Lease Name: PARIS 2
License Status: ACTIVE
Spud Date: 2003-12-16
Permit Date: 2003-11-25
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.017740
Longitude: -78.964840

For data sources see[1][2][3]

Well History

Date Event
2003-11-25 New Permit Application
2003-12-16 Performed Spud Operation
2003-12-18 Drilling Completion
2004-01-09 Perforation
2004-10-05 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2003 DANNIC ENERGY CORP 0.00 0 0.00 0 0.00 0
2004 DANNIC ENERGY CORP 6,893.00 352 0.00 0 0.00 0
2005 DANNIC ENERGY CORP 4,120.00 365 0.00 0 0.00 0
2006 DANNIC ENERGY CORP 2,985.00 365 0.00 0 0.00 0
2007 DANNIC ENERGY CORP 1923.56 365 0.00 0 0.00 0
2008 DANNIC ENERGY CORP 1,231.78 183 0.00 0 0.00 0
2009 DANNIC ENERGY CORP 1,900.68 306 0.00 0 0.00 0
2010 DANNIC ENERGY CORP 1,595.79 365 0.00 0 0.00 0
2011 DANNIC ENERGY CORP 1,099.67 304 0.00 0 0.00 0
2012 DANNIC ENERGY CORP 1,054.44 305 0.00 0 0.00 0
2013 DANNIC ENERGY CORP 1,377.94 304 0.00 0 0.00 0
2014 DANNIC ENERGY CORP 876.00 304 0.00 0 0.00 0
2015 DANNIC ENERGY CORP 742.93 365 0.00 0 0.00 0
2016 DANNIC ENERGY CORP 829.00 366 0.00 0 0.00 0
2017 DANNIC ENERGY CORP 1,044.00 365 0.00 0 0.00 0
2018 DANNIC ENERGY CORP 747.01 365 0.00 0 0.00 0
2019 DANNIC ENERGY CORP 736.84 365 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2004 DANNIC ENERGY CORP Brine 300.00 Bbl Brine or Industrial Waste Treatment Plt PA0101508
2008 DANNIC ENERGY CORP Produced Fluid 80.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2009 DANNIC ENERGY CORP Produced Fluid 162.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0020346
2010 DANNIC ENERGY CORP Produced Fluid 164.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0020346
2011 DANNIC ENERGY CORP Produced Fluid 80.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0028428
2012 DANNIC ENERGY CORP Produced Fluid 80.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028428
2012 DANNIC ENERGY CORP Produced Fluid 80.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0020346
2013 DANNIC ENERGY CORP Produced Fluid 80.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028428
2014 DANNIC ENERGY CORP Produced Fluid 80.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028428
2015 DANNIC ENERGY CORP Produced Fluid 336.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028428
2016 DANNIC ENERGY CORP Produced Fluid 120.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028428
2017 DANNIC ENERGY CORP Produced Fluid 40.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028428
2018 DANNIC ENERGY CORP Produced Fluid 100.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028428
2019 DANNIC ENERGY CORP Produced Fluid 80.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028428

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1389000 Primary Facility 2004-10-20 Site Restoration No Violations Noted
2761854 Primary Facility 2018-08-08 Routine/Complete Inspection No Violations Noted This well was drilled in a forested area off of Team Road in December 2003. No violations were noted during this inspection, but the posted permit numbers should be corrected, stone or a culvert is needed on the access road, and the blow line and brine tank drain valve should be evaluated for leaks.
2769170 Primary Facility 2018-08-28 Routine/Partial Inspection No Violations Noted At the time of inspection, well was producing. The valves were open. There was a separator hooked up, along with a drip catch, and regulator. A chart was in a meter house that was changed on 7/30. A 100 bbl tank was storing fluids. The well was properly labeled. The permit number displayed on the tank doesn't have the correct permit on it though. You may wish to change this to avoid confusion. Production was reported in 2017 as 1044 mcf for 365 days.
2775012 Primary Facility 2018-09-14 Routine/Complete Inspection Violation(s) Noted This well was drilled in a forested area off of Team Road in December 2003. During the previous inspection of the Paris wells on 8/8/2018 (Inspection Record #s 2761851 and 2761854), it was noted that issues were found with material that had been left on site, E&S controls on the access road, and potential leaks from the brine tank and blow line. At that time it was stated that a follow up inspection would be conducted to ensure that these issues had been corrected. At the time of this inspection, no work on correcting these issues has been completed, and violations have been noted.
2783148 Primary Facility 2018-10-02 Follow-up Inspection Outstanding Violations - Viols Req'd This well was drilled in a forested area off of Team Road in December 2003. During the previous inspection of this site on 9/14/2018 (Inspection Record # 2775012), violations were issued regarding E&S controls on the access road and potential leaks from the brine tank and blow line. A NOV response was received by the Department on 10/1/2018 stating that a culvert had been installed and stone used for stabilization of the road service at this site. The response also indicated that a well tag with the correct permit number had been attached to the wellhead, and that the drain valve flange connection and blow line to the brine tank had been replaced. At the time of this inspection, no work on correcting the E&S issues has been completed, and these violations remain open. The well has been tagged with the correct permit number, and the rusted equipment associated with the potential leak has been replaced.
2789005 Primary Facility 2018-10-16 Compliance Evaluation No Violations Noted This well was drilled in a forested area off of Team Road in December 2003. At the time of inspection, work on correcting the E&S issues with the access road has been completed, and the remaining violations have been closed. The well has been tagged with the correct permit number, and the rusted equipment associated with the potential leak has been replaced.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2775012 828054 2018-09-14 2018-10-16 102.11(a)1 Environmental Health & Safety
2775012 828055 2018-09-14 2018-10-16 78.53 Environmental Health & Safety
2775012 828056 2018-09-14 2018-10-16 102.4(b)1 Environmental Health & Safety
2775012 828057 2018-09-14 2018-10-02 OGA3211(H) Administrative
2775012 828058 2018-09-14 2018-10-02 CSL 402(b) Environmental Health & Safety
2783148 829976 2018-10-02 2018-10-16 102.11(a)1 Environmental Health & Safety
2783148 829977 2018-10-02 2018-10-16 78.53 Environmental Health & Safety
2783148 829978 2018-10-02 2018-10-16 102.4(b)1 Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
828054 369733 NOV - Notice of Violation 2018-10-16
828055 369733 NOV - Notice of Violation 2018-10-16
828056 369733 NOV - Notice of Violation 2018-10-16
828057 369733 NOV - Notice of Violation 2018-10-16
828058 369733 NOV - Notice of Violation 2018-10-16
829976 369733 NOV - Notice of Violation 2018-10-16
829977 369733 NOV - Notice of Violation 2018-10-16
829978 369733 NOV - Notice of Violation 2018-10-16

For data sources see[7]