37-063-36505

Well Details

Well ID: 37-063-36505
Loading map...
Country: United States
State: Pennsylvania
County: Indiana
Municipality: White Township
Operator Name: ALLIANCE PETRO CO LLC
Well Pad ID:
Farm/Lease Name: L MCHENRY 5
License Status:
Spud Date: 2009-08-27
Permit Date: 2009-04-09
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: Yes
Latitude: 40.577892
Longitude: -79.210072

For data sources see[1][2][3]

Well History

Date Event
2009-04-09 New Permit Application
2009-08-26 Performed Spud Operation
2009-10-05 Drilling Completion
2009-10-14 Perforation
2010-09-23 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 CONSOL GAS CO 18497.87 365 0.00 0 0.00 0
2010 CONSOL GAS CO 45,463.00 365 0.00 0 0.00 0
2011 CONSOL GAS CO 0.00 0 0.00 0 0.00 0
2012 CNX GAS CO LLC 9,546.00 366 0.00 0 0.00 0
2013 CNX GAS CO LLC 5,405.20 365 0.00 0 0.00 0
2014 CNX GAS CO LLC 640.5 365 0.00 0 0.00 0
2015 CNX GAS CO LLC 1,015.00 365 0.00 0 0.00 0
2016 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2017 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2018 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2009 CONSOL GAS CO Drilling 300.00 Bbl Brine or Industrial Waste Treatment Plt PA0095443
2009 CONSOL GAS CO Fracking Fluid 100.00 Bbl Brine or Industrial Waste Treatment Plt PA0095443
2009 CONSOL GAS CO Drilling 1,400.00 Bbl Brine or Industrial Waste Treatment Plt PA0091472
2009 CONSOL GAS CO Brine 178.00 Bbl Brine or Industrial Waste Treatment Plt PA0091472
2010 CONSOL GAS CO Produced Fluid 603.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2010 CONSOL GAS CO Produced Fluid 175.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0026034
2010 CONSOL GAS CO Produced Fluid 267.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2011 CNX GAS CO LLC Produced Fluid 98.28 Bbl INJECTION DISPOSAL WELL PAS2D912BSOM
2011 CNX GAS CO LLC Produced Fluid 63.00 Bbl INJECTION DISPOSAL WELL 34-133-22523
2011 CNX GAS CO LLC Produced Fluid 60.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 34-099-23127
2011 CNX GAS CO LLC Produced Fluid 79.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2012 CNX GAS CO LLC Produced Fluid 16.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CNX GAS CO LLC Produced Fluid 170.00 Bbl INJECTION DISPOSAL WELL PAS2D912BSOM
2016 CNX GAS CO LLC Produced Fluid 5.00 Bbl INJECTION DISPOSAL WELL 34-013-20609

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1821762 Primary Facility 2009-08-18 Complaint Inspection No Violations Noted Inspection conducted with Oil & Gas Inspector Rick Hoover.
1823634 Primary Facility 2009-08-18 Drilling/Alteration No Violations Noted well site being made - E&S ok
1827328 Primary Facility 2009-09-09 Routine/Complete Inspection No Violations Noted Well is not equipped for production (well head only on site). Site ID sign in place. E&S plan on site.
1829361 Primary Facility 2009-09-08 Drilling/Alteration No Violations Noted drilling commenced - currently shut-in on surface casing awaiting downhole rig/E&S ok/ID&pit ok
1835957 Primary Facility 2009-09-30 Drilling/Alteration No Violations Noted drilling commenced/E&S ok/ID&pits ok
1844354 Primary Facility 2009-11-03 Routine/Complete Inspection No Violations Noted equipped/E&S ok/tank&tag ok
1855782 Primary Facility 2010-01-08 Routine/Complete Inspection No Violations Noted equipped/E&S ok - site being backfilled/tag ok
1895061 Primary Facility 2010-06-29 Complaint Inspection No Violations Noted Well is equipped for production. Well tag in place.
1897248 Primary Facility 2010-07-07 Complaint Inspection No Violations Noted Inspection conducted with oil & gas inspector Rick Hoover and operator representative Mike Gatsky.
1905945 Primary Facility 2010-08-12 Routine/Complete Inspection No Violations Noted Inspection conducted as a follow up to compliance assistance (complaint) inspection of 7/7/10. Well tag in place. Well is equipped for production. Tank appears sound. Vegetated dirt dike around tank. Access road entrance is adequately rocked and stable. Work pad on site is stabilized with rock and vegetation. Entire remainder of site was plowed and planted by surface owner. Additional rock has been installed on access road, ditch lines, and culvert inlet and outlets. Silt fence has been removed and disturbed areas along access road seeded and mulched. These areas are fairly well vegetated. Access road is stabilized. Work pad and portions of site not disturbed by farming operations are stabilized. Site is in compliance. No violations found. Planted fields adjacent to site show multiple signs of erosion. E&S issues in this area appear to originate from the fields.
1922360 Primary Facility 2010-10-22 Site Restoration No Violations Noted Drilling completed 10/5/09. Well tag in place. Well is equipped for production.
1938707 Primary Facility 2010-12-03 Routine/Complete Inspection No Violations Noted Producing gas. TAG, Tank, E&S o.k. Site graded and vegetation started
2089197 Primary Facility 2012-08-01 Complaint Inspection No Violations Noted At the time of this inspection access road appears adequately rocked, there appears to be evidence of a prior erosion concern with mud on township roadway. Well drilled in production. Brine tank appears sound. No accelerated erosion or sedimentation issues on well site. Recommend that operator place "Barrels" on containment in order to prevent a possible pollution event. Site restored. adequate vegetative growth on previously disturbed areas and pad adequately rocked. Recommend operator examine culvert ditch(s) and address issue of accelerated erosion and sedimentation concerns by catching and filter runoff in to culvert outlets. Department has plans to contact operator and discus possible measures to address increased runoff during heavy rain events; it appears some run-off maybe also be coming from surrounding farm field. Similiar complaint recvd July 2010 & looked at by Dep. Insp result pending operator response. 10/2/12 operator successfully implemented additonal bmp's and minimized ES. No sediment reported on raodwayl therefore, no violatio
2094029 Primary Facility 2012-08-21 Routine/Partial Inspection No Violations Noted Onsite meeting to discuss 8/1/2012 inspection and remedial measures to address ES concerns. Reps on Site: Doug Manners Mike Gatski Kevin EschbaughJamie Komonich. Onsite meeting to discuss efforts to address storm water run-off &sedimentation entering township road from well site access road. operator agreed to implement additional storm water management practices in order to minimize the potential for accelerated erosion and sedimentation issues. Tentative plan addition of: 24' compost sox placed in field along access road in order to prevent sedimentation from field along/onto access road,iversion ditch and sediment trap will be install near top of access road at turn,Water bars and additional culverts will be added along access road,relocate culvert and install sediment basin or check dam at outlet in order to prevent such a discharge, and Roadside ditch will be clean out, deepened and re-filled with rock. Operator agreed to send a description of final plan to dept prior to implementation. No viols noted. Operator actively addressing ES
2104579 Primary Facility 2012-10-02 Follow-up Inspection No Violations Noted Follow up to complaint and inspection on 8/15/12. Based on todays inspection and in light of recent rainfall events, it appears that operator has succesfully implemented permanent bmp's capable of resisting erosion and accelerated sedimentation. Therefore, no violations noted at thte time of this inspection.Department reccomends operator continue to mointor and maintain bmp's partilcuarlly after heavy rain events.
2627040 Primary Facility 2017-08-10 Routine/Partial Inspection In Compliance with Schedule On-site meeting held in response to access road concerns expressed by White Township representatives. Present personnel include White Township representatives Tim Willis, Chris Anderson, and Matt Genchur, Operator representative Scott Bower, and Department representative S. Foulk.
2627076 Primary Facility 2017-08-15 Administrative/File Review In Compliance with Schedule Admin inspection in response to inspection record 2627040.

Operator representative Spencer Johnson contacted the Department via phone. In order to prevent any potential pollution events from occurring, maintenance of the access road is scheduled to begin Friday 8/18.

As a result of the concerns expressed in inspection record 2627040, the operator will continue to routinely monitor and maintain the access road as necessary. The operator anticipates plugging of the well. Upon plugging, the access will be restored unless the landowner wishes for it to remain.

2631596 Primary Facility 2017-08-23 Administrative/File Review In Compliance with Schedule Admin inspection in response to inspection record 2627040.

Operator representative Spencer Johnson notified the Department via email that E&S controls are scheduled to be maintained on Monday, August 28, 2017.

2631600 Primary Facility 2017-08-29 Administrative/File Review In Compliance with Schedule Admin inspection in response to inspection record 2627040.

Operator representative Spencer Johnson notified the Department via email that E&S controls are scheduled to be maintained on Wednesday, August 30, 2017. This has been postponed by two days (refer to inspection record 2631596).

2636162 Primary Facility 2017-09-12 Administrative/File Review In Compliance with Policy Admin inspection in response to inspection record 2627040.

Operator representative Spencer Johnson provided pictures to the Department of the access road improvements recently implemented by the Operator.

2817764 Primary Facility 2018-12-20 Routine/Complete Inspection No Violations Noted Well appears to be in good working condition.

For data sources see[7]