37-063-35265

Well Details

Well ID: 37-063-35265
Loading map...
Country: United States
State: Pennsylvania
County: Indiana
Municipality: East Wheatfield Township
Operator Name: XTO ENERGY INC
Well Pad ID:
Farm/Lease Name: KEILMAN 8189
License Status: PLUGGED & ABANDONED
Spud Date:
Permit Date: 2007-03-23
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.434275
Longitude: -78.989231

For data sources see[1][2][3]

Well History

Date Event
2007-03-23 New Permit Application
2007-10-19 Performed Spud Operation
2007-11-01 Drilling Completion
2008-03-14 NEWLY DRILLED
2014-08-29 Drilling Completion
2016-06-28 FULLY PLUGGED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2006 LINN OPR INC 0.00 0 0.00 0 0.00 0
2007 LINN OPR INC 0.00 0 0.00 0 0.00 0
2008 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2009 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2010 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2011 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2012 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2013 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2014 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2015 XTO ENERGY INC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2008 XTO ENERGY INC Drilling 160.00 Bbl Municipal Sewage Treatment Plant PA0026034
2014 XTO ENERGY INC Servicing Fluid 470.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1800671 Primary Facility 2009-05-13 Routine/Complete Inspection No Violations Noted inactive status requested/0 psi surface casing annulus/tag ok
2285373 Primary Facility 2014-07-07 Administrative/File Review In Compliance with Policy On-site pre-construction meeting as requested by Operator representative Dan Rice to review E&S plan prior to commencement of plugging operations. Present parties include WQS Samantha Foulk, Operator representatives Dan Rice and Jason Canose, Mary Kimmel, Phil Morris, and Enterprise representative Phil H.
2312152 Primary Facility 2014-10-09 Routine/Complete Inspection No Violations Noted At time of inspection, well plugged.Plugging completed in August 2014.Aboveground monument installed with permit number affixed. Well spudded 10/19/07, never completed.Regulatory inactive status granted 5/22/09.Prior agreement existed between Opr and Dept regarding timeline of plugging operations.Located adjacent to tree nursery.Pad stable at this time.BMPs functioning properly.Shared AR rocked, in good condition.No accel E&S issues observed.One tank remains on-site.Per current regulations, within 9 months after plugging a well, Opr shall remove all production or storage facilities, supplies and equipment and restore the well site.Hence, Opr has until May 2015 to achieve permanent stabilization and restoration of the well site and remove all associated equipment.Opr shall then submit a well site restoration report to Dept within 60 days after the date of restoration per current regulations.Department recommends Operator continue to monitor and maintain well site in order to ensure final restoration is achieved.

For data sources see[7]