X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-059-26585

Well Details

Well ID: 37-059-26585
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Washington Township
Operator Name: EQT PROD CO
Well Pad ID: 151429
Farm/Lease Name: J&J 591571
License Status:
Spud Date:
Permit Date: 2014-07-15
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 39.995194
Longitude: -80.206244

For data sources see[1][2][3]

Well History

Date Event
2014-07-15 New Permit Application
2014-10-21 New Permit Application
2014-11-15 Performed Spud Operation
2015-03-21 Drilling Completion
2015-07-19 Perforation
2015-07-19 Performed Stimulation
2015-08-12 New Permit Application
2016-04-27 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2015-07-19 2015-08-01 7,520 6,594,630 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Keane Group Carrier/Base Fluid Water 7732-18-5 100 89.4308 55,032,200.0
NALCO EC6330A Keane Group Scale Inhibitor Ethylene Glycol 107-21-1 5 0.00002299 14.145
Sodium Phosphate, Tribasic 7601-54-9 5 0.00002299 14.145
AI 600p Keane Group Acid Corrosion Inhibitor Pyridine, alkyl derives., quaternized with benzyl chloride 68909-18-2 15 0.00005120 31.505
Cinnamaldehyde 104-55-2 15 0.00005120 31.505
1-Decanol 112-30-1 5 0.00001707 10.502
Triethyl Phosphate 78-40-0 2.5 0.00000853 5.251
2-Butoxyethanol 111-76-2 5 0.00001707 10.502
1-Octanol 111-87-5 5 0.00001707 10.502
Alkyl pyridine 68391-11-7 1 0.00000341 2.1
Dimethylformamide 68-12-2 20 0.00006826 42.006
Nonyl phenol ethoxylated, branched 127087-87-0 15 0.00005120 31.505
Ethylene Glycol 107-21-1 40 0.000136526 84.012
Methanol 67-56-1 2.5 0.00000853 5.251
FFR-760 Keane Group Friction Reducer Hydrotreated Light Distillate 64742-47-8 30 0.0218554 13449
Alkyl Alcohol Proprietary 10 0.00728514 4482.99
Oxyalkylated Alcohol A Proprietary 5 0.00364257 2241.49
Hydrochloric Acid (15%) Keane Group Acidizing Hydrochloric Acid 7647-01-0 15 0.0297498 18306.8
AI-250 Keane Group Acid Corrosion Inhibitor Tar Bases, Quinoline Derivs, Benzyl Chloride-Quaternized 72480-70-7 10 0.00001372 8.443
Isopropyl Alcohol 67-63-0 40 0.00005488 33.773
Ethoxylated Nonylphenol 68412-54-4 13 0.00001784 10.976
Propargyl Alcohol 107-19-7 40 0.00005488 33.773
Glycol Ethers 111-76-2 40 0.00005488 33.773
Sand (Proppant) Keane Group Proppant Silica Substrate 14808-60-7 100 10.2965 6,336,060.0
NALCO EC6111A Keane Group Biocide Glutaralhyde 111-30-8 30 0.000158094 97.285

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2015-07-19 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 EQT PROD CO 0.00 0 0.00 0 0.00 0
2015 EQT PROD CO 293,549.00 60 0.00 0 0.00 0
2016 EQT PROD CO 827,514.00 357 0.00 0 0.00 0
2017 EQT PROD CO 507,144.00 365 0.00 0 0.00 0
2018 EQT PROD CO 352,427.00 333 0.00 0 0.00 0
2019 EQT PROD CO 241,545.00 348 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 EQT PROD CO Drill Cuttings 295.00 Tons LANDFILL 101571
2015 EQT PROD CO Produced Fluid 242.00 Bbl INJECTION DISPOSAL WELL 34-059-2-3986
2015 EQT PROD CO Drilling Fluid Waste 1,040.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Produced Fluid 440.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 EQT PROD CO Fracturing Fluid Waste 22.32 Tons LANDFILL 100277
2015 EQT PROD CO Drill Cuttings 712.00 Tons LANDFILL 100419
2015 EQT PROD CO Fracing Fluid Waste 6,496.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Produced Fluid 24,677.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 1,070.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 EQT PROD CO Produced Fluid 980.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 EQT PROD CO Produced Fluid 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2016 EQT PROD CO Produced Fluid 25,220.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 EQT PROD CO Produced Fluid 1,095.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Other Oil & Gas Wastes 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 3,585.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 23.09 Bbl INJECTION DISPOSAL WELL 34-009-23823
2018 EQT PROD CO Other Oil & Gas Wastes 63.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 453.77 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 370.61 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 45.23 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 EQT PROD CO Other Oil & Gas Wastes 192.94 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 472.59 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 84.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2336981 Primary Facility 2014-10-16 Routine/Complete Inspection No Violations Noted Well not drilled, pre-spud inspection.
2338847 Primary Facility 2015-01-23 Drilling/Alteration No Violations Noted top hole drilled; Patterson Rig 255 on pad to drill laterals;
2375625 Primary Facility 2015-05-07 Routine/Complete Inspection No Violations Noted A routine inspection was performed in conjunction with an incident inspection (eFACTs inspection ID#2374439) on the J&J well site on 5/7/15. This site was built approximately 1 year ago and there is currently 8 wells which have been drilled (horizontal and laterals). These wells plan to be completed (fracced) within the next month or so. The lateral portion of 2 additional wells will be drilled within the next week (Well #59171 and #591572). All wells were covered by a steel plate with each distinc t well # was etched into the plate.
2405457 Primary Facility 2015-08-27 Routine/Complete Inspection No Violations Noted Well completed. Flow back operations in progress.
2464177 Primary Facility 2016-03-09 Routine/Complete Inspection No Violations Noted A routine/complete inspection was conducted at the well site. No violations were noted during the inspection.
2681183 Primary Facility 2018-01-09 Routine/Complete Inspection No Violations Noted On Tuesday, January 9, 2018, I conducted a routine-complete inspection at the J & J Well Site located in Washington Township, Greene County.

The gas well, 591571 (059-26585), and associated infrastructure appeared to be in good working order. The well was labelled.

No violations were identified during the inspection.

2691084 Primary Facility 2018-01-26 Routine/Complete Inspection No Violations Noted On Friday, January 26, 2018, I conducted a routine-complete inspection at the J&J Well Site located in Washington Township, Greene County. The inspection was conducted as a result of a property damage complaint received by the Department and alleging that excess water (runoff) from the well site is flooding the neighboring property and the basement of the dwelling on the property.

The gas well, J&J 591571 (059-26585), associated infrastructure appeared to be in good condition and functioning properly. The well was labelled as required.

No violations were identified during the inspection.

2810185 Primary Facility 2018-11-29 Routine/Complete Inspection No Violations Noted On Thursday November 29, 2018 I conducted a routine-complete inspection at the J&J Well Site located in Washington Township, Greene County.

The gas well and the associated infrastructure appeared to be in good condition and functioning properly. The well was tagged with identification.

No violations were identified during the inspection.

For data sources see[9]