37-059-26566

Well Details

Well ID: 37-059-26566
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Washington Township
Operator Name: RICE DRILLING B LLC
Well Pad ID: 151099
Farm/Lease Name: GOOD 7H
License Status:
Spud Date:
Permit Date: 2014-07-08
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 39.990583
Longitude: -80.177636

For data sources see[1][2][3]

Well History

Date Event
2014-07-08 New Permit Application
2015-08-04 Permit Renewal Application
2015-08-12 Performed Spud Operation
2015-11-12 New Permit Application

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2016-03-17 2016-04-13 7,885 8,482,820 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FEAC-20 Keane Iron Control Citric Acid 77-92-9 30 0.00105225 830.111
Acetic Acid 64-19-7 45 0.00157838 1245.17
Bactron K-219 NALCO Biocide Methanol 67-56-1 30 0.00496328 3915.47
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 10 0.00165443 1305.16
Al-11 Keane Corrosion Inhibitor Propargyl Alcohol Derivative Proprietary 60 0.00106628 841.176
Propargly Alcohol 107-19-7 1 0.00001777 14.02
Potassium Iodide 7681-11-0 5 0.00008886 70.098
Water Vantage Carrier/ Base Fluid Water 7732-18-5 100 89.7329 70,789,200.0
TXP-34 Keane Friction Reducer Distillates (Petroleum), Hydrotreated Light 64742-47-8 20 0.0183378 14466.5
Polyacrylamide 69418-26-4 30 0.0275067 21699.7
Alcohols, C12-16, Ethoxylated 68551-12-2 2 0.00183378 1446.65
Water 7732-18-5 43 0.0394263 31102.9
Ammonium Chloride 12125-02-9 0.9 0.000825201 650.991
Oleic Acid Diethanolamide 93-83-4 2 0.00183378 1446.65
100 Mesh Keane Proppant Crystalline Silica in the form of Quartz 14808-60-7 100 4.77299 3,765,350.0
7.5% HCL Keane Acid Hydrochloric Acid 7647-01-0 7.5 0.0463012 36526.5
EC6486A Scale Inhibitor NALCO Scale Inhibitor Ethylene Glycol 107-21-1 20 0.00115361 910.072
Amine Triphosphate Proprietary 20 0.00115361 910.072
40/70 Mesh Sand Keane Proppant Crystalline Silica in the form of Quartz 14808-60-7 100 4.7575 3,753,130.0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2015 VANTAGE ENERGY APPALACHIA II LLC 0.00 0 0.00 0 0.00 0
2016 VANTAGE ENERGY APPALACHIA II LLC 1,046,110.00 122 0.00 0 0.00 0
2017 RICE DRILLING B LLC 1,542,637.32 364 0.00 0 0.00 0
2018 RICE DRILLING B LLC 813,618.00 312 0.00 0 0.00 0
2019 RICE DRILLING B LLC 801,326.00 364 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2015 VANTAGE ENERGY APPALACHIA II LLC Drill Cuttings 235.93 Tons LANDFILL PAD059087072
2015 VANTAGE ENERGY APPALACHIA II LLC Drilling Fluid Waste 2,352.50 Bbl REUSE OTHER THAN ROAD SPREADING
2015 VANTAGE ENERGY APPALACHIA II LLC Drill Cuttings 346.56 Tons RESIDUAL WASTE TRANSFER FACILITY 301071
2016 VANTAGE ENERGY APPALACHIA II LLC Drill Cuttings 497.49 Tons LANDFILL PAD059087072
2016 VANTAGE ENERGY APPALACHIA II LLC Servicing Fluid 25.00 Tons REUSE OTHER THAN ROAD SPREADING
2016 VANTAGE ENERGY APPALACHIA II LLC Fracturing Fluid Waste 41.03 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2016 VANTAGE ENERGY APPALACHIA II LLC Drilling Fluid Waste 25.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 346.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 VANTAGE ENERGY APPALACHIA II LLC Fracturing Fluid Waste 390.63 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW010
2016 VANTAGE ENERGY APPALACHIA II LLC Fracturing Fluid Waste 4.80 Tons LANDFILL 100172
2016 VANTAGE ENERGY APPALACHIA II LLC Fracturing Fluid Waste 16,084.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 VANTAGE ENERGY APPALACHIA II LLC Drill Cuttings 81.30 Tons RESIDUAL WASTE TRANSFER FACILITY 301071
2016 VANTAGE ENERGY APPALACHIA II LLC Waste Water Treatment Sludge 0.80 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2016 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 170.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2016 VANTAGE ENERGY APPALACHIA II LLC Synthetic Liner Materials 4.70 Tons LANDFILL 100620
2016 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 2,412.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2016 VANTAGE ENERGY APPALACHIA II LLC Synthetic Liner Materials 2.36 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2016 VANTAGE ENERGY APPALACHIA II LLC Synthetic Liner Materials 0.41 Tons LANDFILL 100172
2016 VANTAGE ENERGY APPALACHIA II LLC Servicing Fluid 10.85 Tons LANDFILL PAD059087072
2016 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 18.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2016 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 29.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 VANTAGE ENERGY APPALACHIA II LLC Fracturing Fluid Waste 315.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2016 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 9,757.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 VANTAGE ENERGY APPALACHIA II LLC Synthetic Liner Materials 8.05 Tons LANDFILL 100663
2017 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 184.32 Bbl REUSE (AT WELL PAD)
2017 RICE DRILLING B LLC Other Oil & Gas Wastes 48.79 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 113.89 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 254.07 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2017 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 23.34 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 484.31 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 520.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 0.43 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2017 VANTAGE ENERGY APPALACHIA II LLC Synthetic Liner Materials 1.41 Tons LANDFILL 100663
2017 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 33.44 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 1,833.40 Bbl REUSE (AT WELL PAD)
2018 RICE DRILLING B LLC Servicing Fluid 7.46 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 RICE DRILLING B LLC Produced Fluid 203.95 Bbl REUSE (AT WELL PAD)
2018 RICE DRILLING B LLC Other Oil & Gas Wastes 7.78 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 RICE DRILLING B LLC Servicing Fluid 14.59 Bbl REUSE (AT WELL PAD)
2018 RICE DRILLING B LLC Servicing Fluid 7.30 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 RICE DRILLING B LLC Other Oil & Gas Wastes 51.11 Bbl REUSE (AT WELL PAD)
2018 RICE DRILLING B LLC Produced Fluid 184.97 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 RICE DRILLING B LLC Produced Fluid 12.02 Bbl INJECTION DISPOSAL WELL 34-059-24202
2019 RICE DRILLING B LLC Produced Fluid 30.76 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 RICE DRILLING B LLC Produced Fluid 30.03 Bbl RESIDUAL WASTE PROCESSING FACILITY
2019 RICE DRILLING B LLC Produced Fluid 35.10 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 RICE DRILLING B LLC Other Oil & Gas Wastes 48.51 Bbl REUSE (AT WELL PAD)
2019 RICE DRILLING B LLC Produced Fluid 960.55 Bbl REUSE (AT WELL PAD)
2019 RICE DRILLING B LLC Produced Fluid 32.48 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2294664 Primary Facility 2014-06-11 Routine/Complete Inspection No Violations Noted Well not drilled - pre spud inspection.
2304791 Primary Facility 2014-07-23 Routine/Complete Inspection No Violations Noted Well not drilled, pre-spud inspection of site.
2419818 Primary Facility 2015-08-14 Drilling/Alteration No Violations Noted Horizontal Marcellus, Conductor set @ 40’ (26” Dia.) 8/12/2015.
2419837 Primary Facility 2015-10-02 Drilling/Alteration No Violations Noted Horizontal Marcellus, Drilling on air @ 456’ (TD). Setting Water Protection Casing and cementing tonight (10/2/2015).
2419838 Primary Facility 2015-10-05 Drilling/Alteration No Violations Noted Horizontal Marcellus, Drilling on air @ 1052’ (TD). Setting Coal Protection Casing and cementing tonight (10/4/2015).
2419839 Primary Facility 2015-10-09 Drilling/Alteration No Violations Noted Horizontal Marcellus, Drilling on air @ 3239’ (TD). Setting Intermediate Casing and cementing tonight (10/8/2015).
2419841 Primary Facility 2015-10-19 Drilling/Alteration No Violations Noted Horizontal Marcellus, Drilling on air @ 8288’ and mudding well bore with oil base mud (10/14/2015).
2442795 Primary Facility 2016-01-05 Drilling/Alteration No Violations Noted Horizontal Marcellus, Rig moving on to location Good # 7 – H today (1/2/2016).
2442884 Primary Facility 2016-01-07 Drilling/Alteration No Violations Noted Horizontal Marcellus, Rig drilling on air @ 15,080’ (TD). Running 51/2” casing and cementing today ( 1/7/2016).
2483508 Primary Facility 2016-05-04 Incident- Response to Accident or Event In Compliance with Policy An estimated one to two barrels of production water was released from a production tank and directly into containment. The release was the result of a faulty weld and was discovered between stages of fracturing operations. The release was completely contained with no impact to water or soil, the Department was notified according to policy, the response was immediate and the remediation complete. The incident has been determined to be In Compliance with Policy (ICP). No violations are being cited at this time.
2487247 Primary Facility 2016-05-16 Administrative/File Review In Compliance with Policy The separation of a hose from a truck off-loading to an AST through a manifold system resulted in a release of brine at the Good Well Pad on Friday, May 13, 2016. The hose separation resulted from a mechanical failure and released an estimated ½ barrel of brine into containment. Spray from the hose, estimated to be less than a ½ barrel (1/4 to 1/2 barrel) fell beyond containment and impacted gravel on the well pad. The impacted gravel was excavated and disposed off-site. A conductivity probe was used to confirm that all impacted material was removed. The containment was vacuumed out and replaced with new materials. The impacted containment was disposed off-site. Plans are in place to take readings and sample underneath the AST when it is removed to verify that the impact did not extend to or beneath the tank.

The majority of the release was completely contained with no impact to water, the Department was notified according to policy, the response was immediate and the remediation complete. The incid

2823653 Primary Facility 2019-01-04 Routine/Complete Inspection No Violations Noted On Friday January 4, 2019 I conducted a routine-complete inspection at the Good Well Site located in Washington Township, Greene County.

The gas well and the associated infrastructure appeared to be in good condition and functioning properly. The well was tagged with identification.

No violations were identified during the inspection.

2837009 Primary Facility 2019-02-06 Routine/Complete Inspection No Violations Noted On 2/6/2019 at approximately 10:15, I conducted a site restoration inspection of the Good well site located in Washington Township, Greene County to assess site conditions relative to permanent stabilization and permit termination. The following was observed:
  • Act 9 sign located at the site entrance was in good condition.
  • Areas along the access road did not have 70% vegetative cover.
  • Material was observed off the well pad which should be addressed by the operator.
  • Production fluid tanks within secondary containment appeared in good condition.
  • Production equipment appeared in good condition.
  • All wells were marked and appeared in good condition.
  • The site appeared to be stable with no signs of accelerated erosion.

Based on the inspection of the project area, it was determined that all requirements related to permanent stabilization and permit termination had not been attained due to the lack of 70% vegetative cover.

As a result, I do not recommend termination of ESX14-059-0009.

The operat

For data sources see[8]

References