X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-059-26195

Well Details

Well ID: 37-059-26195
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Morris Township
Operator Name: EQT PROD CO
Well Pad ID: 145491
Farm/Lease Name: J MONINGER
License Status: Active
Spud Date: 2014-04-30
Permit Date: 2013-05-24
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 39.971542
Longitude: -80.264564

For data sources see[1][2][3]

Well History

Date Event
2013-05-24 New Permit Application
2013-12-23 New Permit Application
2014-04-30 Performed Spud Operation
2014-08-14 New Permit Application
2015-02-04 New Permit Application

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2015-07-28 2015-08-12 7,846 10,944,700 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) FTS International Proppant Silica Substrate 14808-60-7 100 10.5136 10,778,700.0
MC MX 437-5 Multi-Chem Calcium nitrate solution Calcium nitrate 10124-37-5 60 0.0570053 58442.7
CS-500-SI FTS International Scale inhibitor Ethylene glycol 107-21-1 10 0.00246235 2524.44
Water FTS International Carrier/Base Fluid Water 7732-18-5 100 89.0868 91,333,100.0
FRW-900 FTS International Friction reducer Hydrotreated light distillate 64742-47-8 30 0.0223202 22883
Alkyl alcohol Proprietary 10 0.00744006 7627.66
Oxyalkylated alcohol A Proprietary 5 0.00372003 3813.83
NE-100 FTS International Non-emulsifier Dodecylbenzenesulfonic acid 27176-87-0 5 0.00001813 18.588
2-Butoxyethanol 111-76-2 10 0.00003626 37.177
2-Propanol 67-63-0 10 0.00003626 37.177
FE-100L FTS International Iron control Citric acid 77-92-9 55 0.00004936 50.6
Hydrochloric Acid (15%) FTS International Acidizing Hydrochloric Acid 7647-01-0 15 0.0307011 31475.3
CI-150 FTS International Acid corrosion inhibitor Organic amine resin salt Proprietary 30 0.000111205 114.009
Ethylene glycol 107-21-1 30 0.000111205 114.009
Aromatic aldehyde Proprietary 10 0.00003707 38.003
Quaternary ammonium compound Proprietary 10 0.00003707 38.003
Isopropanol 67-63-0 30 0.000111205 114.009
Dimethylformamide 68-12-2 10 0.00003707 38.003
B-10 FTS International High pH buffer Potassium carbonate 584-08-7 48 0.00003977 40.769
Potassium hydroxide 1310-58-3 20 0.00001657 16.987

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 EQT PROD CO 0.00 0 0.00 0 0.00 0
2015 EQT PROD CO 242,683.00 23 0.00 0 0.00 0
2016 EQT PROD CO 2,671,936.00 362 0.00 0 0.00 0
2017 EQT PROD CO 1,174,603.00 365 0.00 0 0.00 0
2018 EQT PROD CO 789,448.00 365 0.00 0 0.00 0
2019 EQT PROD CO 604,805.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 EQT PROD CO Drill Cuttings 730.97 Tons LANDFILL 100419
2014 EQT PROD CO Drilling Fluid Waste 500.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Fracturing Fluid Waste 39.66 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2015 EQT PROD CO Fracing Fluid Waste 330.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 EQT PROD CO Produced Fluid 330.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 EQT PROD CO Drill Cuttings 698.00 Tons LANDFILL 100419
2015 EQT PROD CO Fracing Fluid Waste 660.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Produced Fluid 7,264.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Other Oil & Gas Wastes 222.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 1,764.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 EQT PROD CO Produced Fluid 434.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 EQT PROD CO Produced Fluid 37,430.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 EQT PROD CO Produced Fluid 830.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 130.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 EQT PROD CO Produced Fluid 2,655.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Other Oil & Gas Wastes 172.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 130.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2017 EQT PROD CO Produced Fluid 65.00 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Other Oil & Gas Wastes 110.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 1,066.80 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 44.70 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Produced Fluid 311.94 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 89.86 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 EQT PROD CO Other Oil & Gas Wastes 9.23 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 10.28 Tons RESIDUAL WASTE PROCESSING FACILITY ODNR 2015-511
2019 EQT PROD CO Other Oil & Gas Wastes 9.23 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 EQT PROD CO Produced Fluid 69.01 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 67.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Other Oil & Gas Wastes 204.61 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 1,433.67 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 70.01 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2281046 Primary Facility 2014-06-09 Drilling/Alteration No Violations Noted 40' OF 20" CONDUCTOR SET. ALPHA HUNTER RIG 8 ON SITE DRILLING TOP HOLE SETS.
2363603 Primary Facility 2015-03-11 Routine/Complete Inspection No Violations Noted Well drilled to TVD, Patterson 227 on site to complete TD.
2467066 Primary Facility 2016-03-18 Routine/Complete Inspection No Violations Noted Well operating and is properly identified. Well is equipped with a production unit. Wellhead and piping appear to be in good condition.
2569061 Primary Facility 2017-03-08 Routine/Complete Inspection No Violations Noted On Monday, March 6, 2017, I conducted a routine/complete inspection at the J. Moninger OG Well Pad located in Morris Township, Greene County.

The Act 9 Sign was in place and clearly legible at the site entrance, as were the gas well API identification signs below the Act 9 signs. All required documentation was also available on-site.

The access road and well pad were in good condition. Some minor rill formation was observed on the access road. The operator should continue their periodic monitoring program and conduct maintenance as warranted.

All PCSM controls have been installed according to plans and are functioning as intended. The site is stabilized via a combination of lush vegetative growth, seed and erosion control matting. The most recent seeded areas exhibit some vegetative growth. The operator should continue their periodic monitoring program and mitigate any signs of accelerated erosion and sediment movement upon identification.

The secondary containment structures on-site are in good co

2589854 Primary Facility 2017-05-03 Site Restoration No Violations Noted On Wednesday, May 3, 2017, I conducted a restoration inspection at the J Moninger OG Well Site located in Morris Township, Greene County. The inspection was the result of an operator submittal of Well Site Restoration Reports in accordance with 25 Pa. Code Section 78.65(3). The well site restoration is an interim restoration while the gas wells on the pad remain in the production stage. The inspection was conducted to confirm that the interim restoration was completed in accordance with the operator's site restoration plan.

Inspection of the site confirmed that the site has been restored to the configuration depicted on the restoration plans.

No violations were identified during the inspection.

For data sources see[8]

References