X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-049-22140

Well Details

Well ID: 37-049-22140
Loading map...
Country: United States
State: Pennsylvania
County: Erie
Municipality: Millcreek Township
Operator Name:
Well Pad ID:
Farm/Lease Name: CLARKS CAR WASH 1
License Status: ACTIVE
Spud Date:
Permit Date: 1985-04-12
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 42.075792
Longitude: -80.173430

For data sources see[1][2][3]

Well History

Date Event
1985-03-01 Drilling Completion
1985-04-12 New Permit Application
1985-08-26 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
1986 TROYER GAS & OIL 1,055.00 0 0.00 0 0.00 0
1991 TROYER GAS & OIL 0.00 0 0.00 0 0.00 0
1992 TROYER GAS & OIL 0.00 0 0.00 0 0.00 0
1993 TROYER GAS & OIL 0.00 0 0.00 0 0.00 0
1994 TROYER GAS & OIL 0.00 0 0.00 0 0.00 0
1997 TROYER GAS & OIL 481 90 0.00 0 0.00 0
1998 TROYER GAS & OIL 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1443333 Primary Facility 2005-04-21 Routine/Complete Inspection No Violations Noted
2748658 Primary Facility 2018-07-05 Routine/Partial Inspection No Violations Noted Inspected location, well sits behind car wash in a residential area in millcreek, well is going to be plugged, meeting with local officials and plugging contractor since well is a known h2s well.
2754412 Primary Facility 2018-07-17 Routine/Partial Inspection No Violations Noted Inspected location, plugging crew on location, 0600 well was blown down, crew the disconnected wellhead and found that there was tubing in hole set on a packer, tubing then was shot off at top of packer and tubing was then pulled, a CIBP was then set on top of packer and hole was filled from CIBP to surface.
2775063 Primary Facility 2018-09-14 Routine/Complete Inspection No Violations Noted Routine inspection of well site. Well was recently plugged (July 2018). Casing cut-off below grade. Fully vegetated site. Refer to inspection ID #s 2758658 and 2754412 for OGI plugging inspection info.
366237 Primary Facility 1990-07-17 Routine/Complete Inspection No Violations Noted SRF#60-90-25-017
366239 Primary Facility 1990-07-18 Routine/Complete Inspection No Violations Noted SRF# 60-90-25-017
366240 Primary Facility 1990-07-19 Routine/Complete Inspection No Violations Noted SRF# 60-90-025-017
366241 Primary Facility 1990-07-20 Routine/Complete Inspection No Violations Noted
366242 Primary Facility 1990-07-23 Routine/Complete Inspection No Violations Noted SRF# 60-90-25-017
366279 Primary Facility 1990-08-01 Routine/Complete Inspection Violation(s) Noted
366516 Primary Facility 1990-09-04 Drilling/Alteration No Violations Noted
367394 Primary Facility 1990-12-21 Routine/Complete Inspection No Violations Noted

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
366279 91546 08/01/1990 1990-08-01 201TAG - Failure to install, in a permanent manner, the permit number on a completed well Administrative
366279 91547 08/01/1990 1990-08-01 215 - Failure to bond well, replace or maintain bond Administrative

For data sources see[6]

References