37-049-00066

Well Details

Well ID: 37-049-00066
Loading map...
Country: United States
State: Pennsylvania
County: Erie
Municipality: Summit Township
Operator Name:
Well Pad ID:
Farm/Lease Name: SERIAL 1583P 1583
License Status: Abandoned
Spud Date:
Permit Date:
Well Type: STORAGE WELL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 42.053056
Longitude: -80.057139

For data sources see[1][2][3]

Well History

Date Event
1956-04-02 Drilling Completion
2017-10-10 Old Well
2017-12-12 Begin Plugging
2017-12-21 Finished Plugging

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2011 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2012 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2013 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2014 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2015 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2016 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2017 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1082693 Primary Facility 2001-12-11 Routine/Complete Inspection No Violations Noted
1298344 Primary Facility 2003-12-16 Routine/Complete Inspection No Violations Noted
1839841 Primary Facility 2009-10-22 Routine/Complete Inspection No Violations Noted
1919647 Primary Facility 2010-10-12 Routine/Complete Inspection No Violations Noted
2014050 Primary Facility 2011-10-26 Routine/Complete Inspection No Violations Noted
2107946 Primary Facility 2012-10-10 Routine/Complete Inspection No Violations Noted
2213212 Primary Facility 2013-10-16 Routine/Complete Inspection No Violations Noted
2306399 Primary Facility 2014-09-22 Routine/Complete Inspection No Violations Noted
2421687 Primary Facility 2015-10-27 Routine/Partial Inspection No Violations Noted
2533615 Primary Facility 2016-11-02 Routine/Complete Inspection No Violations Noted
2655918 Primary Facility 2017-11-01 Routine/Partial Inspection No Violations Noted
2669217 Primary Facility 2017-12-11 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspected location, well pad has been built, no equipment is currently on location.
2670302 Primary Facility 2017-12-13 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspected location, rig and plugging equipment on location, crew pumped 66 bbls of fluid to kill the well, crew now preparing to rig up flare stack to finish killing the well then will rig up BOP.
2673043 Primary Facility 2017-12-20 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspected location, while setting bottom plug cement string became differentially stuck in hole, a 1 11/16's inch bond log was run inside tubing, touched down on cement @ 1384', pipe was then cut at 1384', two more runs were made with bond log one with pressure and one without pressure, tubing was run back in hole to 1377' then gel was spotted, 5.9 bbls of cement was spotted , 12 joints were pulled to 984', then a cement plug was spotted from 984-786' with 7.8 bbls of cement, crew then pulled up to 384' and set another cement plug with 11.8 bbls of cement to 88', rig crew was rigging down for day and will return to tag TOC in morning, a new plugging procedure will be sent to Dept.
2681516 Primary Facility 2018-01-11 Administrative/File Review No Violations Noted Admin inspection for review of plugging certificate.
2803243 Primary Facility 2018-11-14 Routine/Complete Inspection No Violations Noted
361135 Primary Facility 1988-11-15 Routine/Complete Inspection No Violations Noted
361136 Primary Facility 1989-11-14 Routine/Complete Inspection No Violations Noted
367527 Primary Facility 1990-12-19 Routine/Complete Inspection No Violations Noted
369971 Primary Facility 1991-09-24 Routine/Complete Inspection No Violations Noted
372768 Primary Facility 1992-10-28 Routine/Complete Inspection No Violations Noted
375449 Primary Facility 1993-12-28 Routine/Complete Inspection No Violations Noted
377196 Primary Facility 1994-12-14 Routine/Complete Inspection No Violations Noted
379989 Primary Facility 1995-12-14 Routine/Complete Inspection No Violations Noted
383719 Primary Facility 1997-10-30 Routine/Complete Inspection No Violations Noted
386229 Primary Facility 1998-10-21 Routine/Complete Inspection No Violations Noted
893748 Primary Facility 1999-11-01 Routine/Complete Inspection No Violations Noted

For data sources see[6]

References