37-035-21227

Well Details

Well ID: 37-035-21227
Loading map...
Country: United States
State: Pennsylvania
County: Clinton
Municipality: Grugan Township
Operator Name: ARD OPR LLC
Well Pad ID: 148052
Farm/Lease Name: COP TRACT 285 B1004H
License Status:
Spud Date:
Permit Date: 2010-11-18
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.369308
Longitude: -77.559458

For data sources see[1][2][3]

Well History

Date Event
2010-09-10 Performed Spud Operation
2010-11-18 New Permit Application
2010-12-30 Drilling Completion
2011-04-01 Perforation
2012-04-19 DEVIATED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2011 ANADARKO E&P ONSHORE LLC 644,146.00 237 0.00 0 0.00 0
2012 ANADARKO E&P ONSHORE LLC 520,438.00 351 0.00 0 0.00 0
2013 ANADARKO E&P ONSHORE LLC 426,908.00 329 0.00 0 0.00 0
2014 ANADARKO E&P ONSHORE LLC 329,530.00 338 0.00 0 0.00 0
2015 ANADARKO E&P ONSHORE LLC 225,550.00 231 0.00 0 0.00 0
2016 ANADARKO E&P ONSHORE LLC 242,698.00 366 0.00 0 0.00 0
2017 ARD OPR LLC 191,459.18 365 0.00 0 0.00 0
2018 ARD OPR LLC 166,050.55 360 0.00 0 0.00 0
2019 ARD OPR LLC 153,261.61 365 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 ANADARKO E&P ONSHORE LLC Produced Fluid 2,636.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE
2012 ANADARKO E&P ONSHORE LLC Produced Fluid 1,766.60 Bbl REUSE OTHER THAN ROAD SPREADING
2013 ANADARKO E&P ONSHORE LLC Produced Fluid 1,940.47 Bbl REUSE OTHER THAN ROAD SPREADING
2014 ANADARKO E&P ONSHORE LLC Produced Fluid 821.35 Bbl REUSE OTHER THAN ROAD SPREADING
2015 ANADARKO E&P ONSHORE LLC Produced Fluid 161.67 Bbl REUSE OTHER THAN ROAD SPREADING
2015 ANADARKO E&P ONSHORE LLC Produced Fluid 66.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2015 ANADARKO E&P ONSHORE LLC Produced Fluid 9.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 10.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 164.57 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 270.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 65.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 38.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 26.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 10.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 126.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 ARD OPR LLC Produced Fluid 23.32 Bbl REUSE (AT WELL PAD)
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 59.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 ARD OPR LLC Produced Fluid 85.30 Bbl REUSE (AT WELL PAD)
2019 ARD OPR LLC Produced Fluid 230.80 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1933657 Primary Facility 2010-12-08 Drilling/Alteration No Violations Noted Precision 528 drilling a 12 1/4" hole @ 1240'
1934553 Primary Facility 2010-12-10 Routine/Partial Inspection No Violations Noted
1939664 Primary Facility 2010-12-28 Drilling/Alteration No Violations Noted Drilled to TD of 13151' Tripping out of hole and preparing to run casing.
1939844 Primary Facility 2010-12-30 Routine/Partial Inspection No Violations Noted
1942754 Primary Facility 2011-01-06 Drilling/Alteration No Violations Noted Well drilled to TD, production casing cemented.
1944097 Primary Facility 2011-01-20 Routine/Partial Inspection No Violations Noted
1955814 Primary Facility 2011-03-08 Routine/Complete Inspection No Violations Noted
1957114 Primary Facility 2011-03-14 Routine/Complete Inspection No Violations Noted
1962234 Primary Facility 2011-03-31 Routine/Partial Inspection No Violations Noted
1966221 Primary Facility 2011-04-13 Routine/Partial Inspection No Violations Noted
1970591 Primary Facility 2011-04-29 Routine/Partial Inspection No Violations Noted
1972033 Primary Facility 2011-05-09 Routine/Complete Inspection No Violations Noted
2027927 Primary Facility 2011-12-06 Routine/Complete Inspection No Violations Noted
2039263 Primary Facility 2012-01-03 Routine/Complete Inspection No Violations Noted
2062132 Primary Facility 2012-03-15 Routine/Complete Inspection No Violations Noted
2105080 Primary Facility 2012-09-19 Routine/Complete Inspection No Violations Noted
2190409 Primary Facility 2013-08-08 Routine/Complete Inspection No Violations Noted
2553223 Primary Facility 2017-01-09 Routine/Complete Inspection No Violations Noted
2695846 Primary Facility 2018-02-13 Routine/Complete Inspection No Violations Noted The weather is 36 Deg. F and sunny at time of inspection. Routine inspection of Alta Resources, LLC., C.O.P. TRACT 285B Pad, Well #1004H, on February 13, 2018.

There are 6 producing wells on this pad. Both annulus vents are closed and not vented at time of inspection. Production by intermediate (5-1/2¿ X 9-5/8¿) annulus vent is shut in to pressure monitor, with pressure reading ¿ 0 PSI, production casing annulus vent is also shut in to pressure monitor, with pressure reading -230 PSI. The production xmas tree top pressure on the 2-3/8¿ tubing is 146 PSI. 0% combustible gas was detected at the annulus or in the area immediately surrounding the well. No obvious concerns or violations are noted at time of inspection. Wellsite looks neat and well organized. DEP Representative - Ulyana Trynovich, Oil and Gas Inspector.

2760259 Primary Facility 2018-07-25 Routine/Complete Inspection No Violations Noted On July 25, 2018, Department representative Sue Herzing conducted a routine site inspection at COP TRACT 285 PAD B. The site sign, emergency response plan, monthly tank maintenance log, ESCGP, weekly E&S inspection log, and drilling permits were onsite for review. No E&S issues were observed during the time of my inspection. A PCSM infiltration berm consisting of a 24" seeded compost sock has been installed according to PCSM plans. This compost infiltration berm is well vegetated and appears to be functioning as design. The pad remains the original footprint size of 400' x 400'. According to the operators PCSM plans, this the smallest "in production" workable footprint size. The following remain in place along the access road and appear to be functioning as design: rock lined roadside ditches and ditch relief culverts with rip-rap aprons. Overall, the site is stable and well vegetated exceeding 70% uniform, perennial, vegetative cover.

There are a total of 6 producing wells located on this well pad. All wel

2845172 Primary Facility 2019-02-26 Routine/Complete Inspection No Violations Noted Inspection was in response to a deficient tank notification from ARD received on 2/25/19. A hole was discovered above the water level, and the tank was taken out of service and pumped down. I immediately noted several rust streaks on the #1 tank, and also noted that the #3 tank had similar rust streaks; I recommend that the #3 tank be monitored carefully for integrity. 3-4" of ice was present in the production tank containment; although the capacity of the containment did not appear to be significantly reduced, I recommend that when conditions warrant that this containment be vacced out. The GPU containment was full to the top of the berm with ice; I recommend that this be vacced as soon as reasonably possible.
2855411 Primary Facility 2019-03-18 Routine/Complete Inspection No Violations Noted Weather was 20 degrees and sunny. There were no Alta representatives on location at time of inspection. Well was in production. Well had digital pressure monitoring equipment. Well had 133 PSI on the production tubing and 173 PSI on the production casing. Well had 2 visible annulus vents plumbed to surface. 1' annulus vent had a 0 to 600 PSI analog pressure gauge reading approximately 0 PSI. 2' annulus vent had a 0 to 3K PSI analog pressure gauge reading approximately 1750 PSI. 0% combustible gas was detected around the well. No violations at time of inspection.

For data sources see[7]